Electronic Gas Detection Leak Testing Equipment
from Busch Vacuum Solutions
Leaks in vacuum systems can cause considerable damage in sensitive industrial processes. Vacuum pumps may fail or require more frequent service. The output quality can suffer, and losses in energy efficiency can occur. As a result, energy costs and overall operating costs increase drastically. Our... [See More]
- Leak Test Method: Electronic Gas Detection
- Display Type: Digital Readouts
- Local Interface: Digital Front Panel
from MSA Safety
The Chillgard 5000 Leak Detector provides continuous, real-time monitoring down to 1 ppm. The Chillgard 5000 Refrigerant Leak Monitor provides the earliest level of detection of costly refrigerant gas leaks in mechanical equipment rooms. Sampling system with patented photoacoustic infrared (PAIR)... [See More]
- Leak Test Method: Electronic Gas Detection; Photoacoustic Infrared
- Local Interface: Digital Front Panel
- Output Options: Analog Voltage; Analog Current
- Features: Memory capability or Data Logging; Audible Alarm Option
from Agilent Technologies - Vacuum Products
The PHD-4 sniffer leak detector is a lightweight and rugged sniffer, sensitive to helium concentrations as low as 2 ppm – equivalent to a leak rate of 5 x 10 –6 atm-cc/sec, far superior to bubble-testing, dye penetrants, and pressure decay. The sensitivity of the PHD-4 is enabled by... [See More]
- Leak Test Method: Electronic Gas Detection
- Operating Temp: 23 to 95
from Pfeiffer Vacuum, Inc.
Flexible: Modular design, small footprint, easy integration into any leak detection system Accurate: High sensitivity, repeatable measurements, suitable for short cycle time and high production throughput Robust: High reliability, long maintenance intervals [See More]
- Leak Test Method: Electronic Gas Detection
- Operating Temp: 50 to 113
- Computer Interface Options: Serial Interface
from Busch Vacuum Solutions
Leaks in vacuum systems can cause considerable damage in sensitive industrial processes. Vacuum pumps may fail or require more frequent service. The output quality can suffer, and losses in energy efficiency can occur. As a result, energy costs and overall operating costs increase drastically. Our... [See More]
- Leak Test Method: Electronic Gas Detection
- Display Type: Digital Readouts
- Local Interface: Digital Front Panel
from MSA Safety
Instantly detect pressurized gas leaks with this high-precision, omni-direction acoustic detector utilizing Gassonic ultrasonic technology. Works even when traditional methods of gas detection are unsuitable or dependent on ventilation. Features Artificial Neural Network (ANN) technology that... [See More]
- Leak Test Method: Electronic Gas Detection; Hydrogen Leak Detection; Ultrasonic Leak Detector
- Local Interface: Computer Interface
- Output Options: Analog Current
- Computer Interface Options: Serial Interface
from Pfeiffer Vacuum, Inc.
Highly sensitive: Helium leak detection down to ≥0.01 µm, specially designed for validating sterile packaging Deterministic: Quantifiable and repeatable results according to USP <1207 > standard Versatile: Turnkey solution with customized test chambers, adaptable to vials,... [See More]
- Leak Test Method: Electronic Gas Detection
- Computer Interface Options: Serial Interface
- Local Interface: Digital Front Panel
- Software: Application Software Included
from Pfeiffer Vacuum, Inc.
Accurate: High sensitivity, repeatable measurements Compact: Small footprint, suitable for desktop use or integration into production lines User-friendly: Visual management of test results on large high resolution color display as well as on dedicated sniffer probe [See More]
- Leak Test Method: Electronic Gas Detection
- Computer Interface Options: Serial Interface
- Local Interface: Digital Front Panel; Computer Interface
- Display Type: Digital Readouts
from Transcat, Inc.
Dwyer Instruments CLD20 Combustible Gas Leak Detection Meter/Ammonia [See More]
- Leak Test Method: Electronic Gas Detection
from Sensidyne, LP
Sensidyne is a leading provider of gas detection systems designed to detect toxic and combustible gas levels in ambient air in a variety of industries. Permanent gas detection systems protect your plant and personnel from a variety of toxic gases and/or combustible gases with leading technologies... [See More]
- Leak Test Method: Electronic Gas Detection
- Local Interface: Digital Front Panel
- Output Options: Analog Current; Switch or Alarm Signal (optional feature)
- Display Type: Digital Readouts
from Transcat, Inc.
Product Highlights. Combustible Gas Leak Detector capable of displaying ppm or%LEL (Lower Explosive Limit). Designed to meet UL 913 intrinsic safety (Approval Pending). 10 ppm sensitivity (methane). Instant response. Electronic tick rate control. Settable alarm. Visual and audible leak indication. [See More]
- Leak Test Method: Electronic Gas Detection
from Transcat, Inc.
Product Highlights. Dual readout displays % of LEL of combustible gas and ppm of CO. Pump driven for fast response. Infrared printer interface for “hardcopy ” output. Audible & visual alarms. Push-button operation. Flexible 16'' gooseneck. Combustible Gasses Detected (Partial List)... [See More]
- Leak Test Method: Electronic Gas Detection