Hydrogen Chloride (HCl) Gas Sensors

15 Results
FTIR System Solution Continuous Emission Monitor -- ACF-NT
from ABB Measurement & Analytics

Continuous Emission Monitoring Solution. World leader in stack gas monitoring systems for more than 40 years and pioneer in FTIR technology, ABB Analytical is offering an inexpensive and forward-looking system with the ACF-NT (former Advance Cemas FTIR) multi-component emission and process... [See More]

  • Gas Types: NH3 (0-20/27 ppm); CO2 (0-30 Vol%); CO (0-60 ppm); HCl (0-10 ppm); Methane (CH4) / Natural Gas (0-150 ppm); NO (0-150 ppm); NO2 (0-20 ppm); NxOx (0-25 ppm); SO2 (0-25 ppm); Water Vapor (0-40 Vol%)
  • Number of Gases Monitored: Multi
  • Sensor Technology: FTIR
  • Measurement Type: %Volume; Trace; Density
Open Path Gas Detector -- Senscient ELDS™
from MSA Safety

Senscient open path gas detector ensures best in class false alarm rejection. The Senscient ELDS laser-based open path gas detector is available for a wide range of toxic and flammable gases. The Senscient ELDS uses 'SimuGas' self-testing to eliminate employees entering hazardous areas for gas... [See More]

  • Gas Types: Toxic; NH3; CO2; HCl; HF; H2S; Methane (CH4) / Natural Gas
  • Number of Gases Monitored: Single; Multi (optional feature)
  • Sensor Technology: Enhanced Laser Diode Spectroscopy
  • Measurement Type: %Volume
Smart Gas Sensor - Hydrogen Chloride (HCl) -- Model SA2-HCL
from Safeguard Analytics

Model SA2-HCL smart sensor modules are designed to detect and monitor hydrogen chloride gas in ambient air. The modules consist of an electrochemical gas detection sensor and a microprocessor signal conditioning circuit. The signal conditioning circuits includes embedded temperature compensation and... [See More]

  • Gas Types: HCl (0-1 ppm to 0-200 ppm)
  • Number of Gases Monitored: Single
  • Sensor Technology: Electrochemical
  • Measurement Type: Trace
Electrochemical Gas Sensor, 4 Series -- 4CL2-10
from Electro Optical Components, Inc.

SemeaTech, a world leader in sensing technologies, offers a full line of electrochemical sensors for detecting hazardous materials and gases for work safety and environmental protection. SemeaTech has built a wide network of industry experts and technologists to provide the company with guidance for... [See More]

  • Gas Types: HCl (0-10 ppm)
  • Number of Gases Monitored: Single
  • Sensor Technology: Electrochemical
  • Measurement Type: Trace
Detector Tube -- 9003-26
from Terra Universal, Inc.

Complete, easy-to-use sampling and analysis system. Detects and measures hazardous gases and vapors. Certified by the Safety Equipment Institute (SEI). Ideal for monitoring performance of Terra Exhaust Purification Filters. The most cost effective solution to air sampling and analysis. This Toxic... [See More]

  • Gas Types: Toxic; HCl (20 to 1200 PPM)
  • Number of Gases Monitored: Single
  • Sensor Technology: Colorimetric Stain
  • Measurement Type: Trace
Eight Channel Gas Controller -- P2260
from Conspec Controls Inc.

CONSPEC Controls Multi-Channel Controller is a microprocessor-based multi-analog input controller. The P2259/60 was designed to be an independent stand-alone controller but can integrate into any type of data acquisition system. The Controller can provide up to eight channels of remote monitoring... [See More]

  • Gas Types: Combustible; Aerosols; NH3; AsH3; Br2; CO2; CO; Cl2; ClO2; B2H6; F; GeH4; Refrigerants; Hydrocarbons; H2; HCl; HCN; HF; H2Se; H2S; NO; NO2; O2; O3; PH3; SiH4; SO2; SF6
  • Number of Gases Monitored: Multi
  • Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
  • Measurement Type: %LEL or %LFL; %Volume; Trace
Process Gas Analyzer -- CT5400
from Emerson Automation Solutions – Rosemount

This multi-component QCL represents the next generation of gas analyzers and sensors, with the ability to measure up to 20 gases and an interchangeable modular configuration for up to 9 lasers. An embedded ARM processor gives fully autonomous intelligent operation. Key Features/Benefits: Measure up... [See More]

  • Gas Types: Combustible; NH3 (0-4000 ppm); CO2 (0-30%); CO (0-20000 ppm); Hydrocarbons (0-200 ppm); HCl (0-2000 ppm); HF (0-50 ppm); H2S (0-50000 ppm); Methane (CH4) / Natural Gas (0-20000 ppm); NO (0-10000 ppm); NO2 (0-2000 ppm); NxOx (0-10000 ppm); O2 (0-100%); SO2 (0-4000 ppm); Water Vapor (0-40%) (Formaldehyde 0-100ppm, Hydrogen Peroxide 0-800ppm, Methanol 0-120 ppm, Nitromethane 0-120ppm)
  • Number of Gases Monitored: Multi
  • Sensor Technology: Infrared
  • Measurement Type: %Volume; Trace
Refillable SensAlert HCL 10ppm -- 081201-D-1X
from Sensidyne, LP

Minimum Indicated Concentration .............. 0.4 ppm. Repeatability .............................................. ± 10% of reading. Accuracy * ................................................. ± 10% of full scale. Zero Drift ................................................... <... [See More]

  • Gas Types: Toxic; HCl (0-10ppm)
  • Number of Gases Monitored: Single
  • Sensor Technology: Electrochemical
  • Measurement Type: Trace
Gas Sensor -- GAS
from RainWise, Inc.

Rainwise offers customized turnkey weather monitoring solution. [See More]

  • Gas Types: Toxic (optional feature); Combustible (optional feature); NH3 (Contact Factory); AsH3 (Contact Factory); Br2 (Contact Factory); CO (Contact Factory); Cl2 (Contact Factory); ClO2 (Contact Factory); B2H6 (Contact Factory); F (Contact Factory); GeH4 (Contact Factory); H2 (Contact Factory); HCl (Contact Factory); HCN (Contact Factory); HF (Contact Factory); H2Se (Contact Factory); H2S (Contact Factory); NO (Contact Factory); NO2 (Contact Factory); O2 (Contact Factory); O3 (Contact Factory); PH3 (Contact Factory); SiH4 (Contact Factory); SO2 (Contact Factory)
  • Number of Gases Monitored: Single
  • Sensor Technology: Electrochemical
  • Measurement Type: %LEL or %LFL; Trace
Sensor Transmitter -- GDS-49
from Global Detection Systems Corp.

The GDS-49 is a two-wire loop-powered 4-20mA sensor transmitter designed to detect a wide range of toxic gases at ppm levels. The current loop output is compatible with the C1 Protector, C2 Protector, C2 Quad Protector or C64 Protector Controllers, the GASMAX II or GASMAX CX gas monitors or any... [See More]

  • Gas Types: Toxic; Combustible; NH3 (0-100 ppm); AsH3 (0-1 ppm); CO (0-300/1000 ppm); Cl2 (0-5/50 ppm); ClO2 (0-1 ppm); F (0-1 ppm); H2 (0-2000 ppm); HCl (0-30 ppm); HCN (0-50 ppm); HF (0-10 ppm); H2S (0-50/100 ppm); NO (0-100/500 ppm); NO2 (0-5/50 ppm); O2 (0-25%); O3 (0-1 ppm); SiH4 (0-50 ppm); SO2 (0-20/100 ppm) (COCI2 0-1ppm N2H4 0-1ppm TBM 0-14ppm)
  • Number of Gases Monitored: Multi
  • Sensor Technology: Electrochemical
  • Measurement Type: %LEL or %LFL (optional feature); Trace (optional feature)
Apex Gas Transmitter and Sensor
from Honeywell Analytics, Inc.

Highest performance fixed flammable and toxic gas detector with a choice of communication outputs, accessories and installation flexibility. Apex takes the best elements of gas detection design and combining them into one unit. Apex provides the highest performance, installation flexibility, a wide... [See More]

  • Gas Types: Toxic; Combustible; NH3 (0-50 PPM / 0-1000 PPM); AsH3 (0-0.2 PPM); Br2 (0-0.4 PPM); CO (0-100 PPM / 0-500 PPM); Cl2 (0-2 PPM / 0-15 PPM); ClO2 (0-0.4 PPM); B2H6 (0-0.4 PPM); F (0-4 PPM); GeH4 (0-0.8 PPM); Hydrocarbons (0-100% LEL); H2 (0-1000 PPM); HCl (0-20 PPM); HCN (0-20 PPM); HF (0-12 PPM); H2S (0-15 PPM / 0-100 PPM); NO (0-100 PPM); NO2 (0-12 PPM); O2 (0-21 % v/v); O3 (0-4 PPM); PH3 (0-1.2 PPM); SiH4 (0-20 PPM); SO2 (0-8 PPM / 0-50 PPM) (Many other toxic gases- see datasheet)
  • Number of Gases Monitored: Multi
  • Sensor Technology: Catalytic; Electrochemical
  • Measurement Type: %LEL or %LFL; %Volume; Trace
ELDS Open Path Gas Detector -- 1000 Series Hydrogen Chloride
from Senscient Inc.

Reliable, open path detection of hydrogen chloride at levels low enough to provide early warning for leakage of this highly toxic gas. Detection Limits for hydrogen chloride leak detection are orders of magnitude lower than any other OPGD product. Specific detection of Hydrogen Chloride without any... [See More]

  • Gas Types: Combustible; HCl (0-50ppm)
  • Number of Gases Monitored: Single
  • Sensor Technology: Infrared; Enhanced Laser Diode Spectroscopy
  • Measurement Type: %LEL or %LFL; Trace; Leakage; Signature
Single Channel Gas Controller -- P2065
from Conspec Controls Inc.

CONSPEC's Single Channel Controllers are single point monitoring and control processors, which are housed in a NEMA 4-4X weatherproof non-metallic enclosure and are designed to monitor and display any voltage or current input signal from any instrument, including CONSPEC's EZ-CAL Toxic and... [See More]

  • Gas Types: Toxic; Combustible; Aerosols; NH3 (0-50, 100, 200, 500ppm); AsH3; Br2 (0-10ppm); CO2 (0-2000ppm, 10000ppm 0-2%, 0-5%, 0-100%); CO (0-50, 100, 200, 500, 1000, 10000, 50000); Cl2 (0-10, 20ppm); ClO2 (0-5 ppm); B2H6; F; GeH4; Refrigerants; Hydrocarbons (0-100% LEL or 0-100% Vol.); H2 (0-2000, 10,000ppm 0-4%); HCl (0-25, 100, 150ppm); HCN; HF; H2Se; H2S (0-25, 50, 100, 200ppm); NO (0-50, 100ppm); NO2 (0-20ppm); O2 (0-25, 100%); O3 (0-2, 5ppm); PH3; SiH4; SO2 (0-10, 100, 1000, 2000ppm); SF6
  • Number of Gases Monitored: Single
  • Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
  • Measurement Type: %LEL or %LFL; %Volume; Trace
SensAlert HCI Sensor 100ppm -- 081232-D-2
from Sensidyne, LP

Minimum Indicated Concentration .............. 4 ppm. Repeatability .............................................. ± 2% of reading. Accuracy * ................................................. ± 2% of full scale. Zero Drift ................................................... < 5%... [See More]

  • Gas Types: Toxic; HCl (0-100ppm)
  • Number of Gases Monitored: Single
  • Sensor Technology: Electrochemical
  • Measurement Type: Trace
Series 3000 MkII Gas Transmitter with Sensor
from Honeywell Analytics, Inc.

Toxic, 2 wire loop powered 4-20mA gas transmitter with integral gas concentration display. The Series 3000 MkII provides comprehensive monitoring of toxic and Oxygen gas hazards in potentially explosive atmospheres, both in and out of doors. This low powered gas detector operates on an industry... [See More]

  • Gas Types: NH3 (50 to 1,000 ppm); CO (100 to 1,000 ppm); Cl2 (50 to 20 ppm); ClO2 (0 to 1 ppm); H2 (0 to 10,000 ppm); HCl (10 to 20 ppm)
  • Number of Gases Monitored: Single
  • Sensor Technology: Electrochemical
  • Electrical Outputs: Current