Analog Voltage Gas Sensors
Description
Analog Voltage Gas Sensors are devices that detect the presence and concentration of gases in the environment and provide an output in the form of an analog voltage signal. This output is proportional to the concentration of the gas detected, allowing for real-time monitoring and measurement.
Working Principle
Analog Voltage Gas Sensors typically operate based on electrochemical principles. As the concentration of a specific gas increases, the sensor produces a corresponding increase in electrical output, either in amperage or voltage. This analog signal can then be used to drive instruments like ammeters or voltmeters, which display the gas concentration on a dial gauge. The simplicity of the analog output allows for straightforward integration into various monitoring systems .
Applications
Analog Voltage Gas Sensors are used in a variety of applications where real-time gas monitoring is essential. Specific examples include industrial safety systems for detecting flammable gases, environmental monitoring for air quality assessment, and residential safety devices for detecting carbon monoxide or propane leaks.
Advantages over other Gas Sensors
One of the main advantages of Analog Voltage Gas Sensors is their cost-effectiveness compared to digital gas sensors. The absence of additional electronics, such as ADC chips, makes them less expensive while still providing fast response times for gas detection .
Limitations
Analog Voltage Gas Sensors have certain limitations, including a narrower temperature range and pressure range for accurate operation. For example, electrochemical cells used in these sensors have a working pressure range of only 10% within atmospheric pressure, and deviations from this range can affect measurement accuracy .
Considerations
When considering Analog Voltage Gas Sensors, it is important to evaluate factors such as initial costs, which are generally lower than digital sensors due to simpler electronics. However, operating expenses may vary depending on the specific gas being monitored and the environmental conditions. Durability can be affected by extreme temperatures and humidity, which may also impact sensor accuracy and lifespan. Regular maintenance and calibration are necessary to ensure reliable performance, and replacement costs should be factored into long-term operational budgets .
from Analytical Industries Inc.
Key features. Measuring Range: 0-100%. Signal Output: 3.5 - 5.5 mV. Response Time T90: 9 sec. Accuracy: +/-2% of Full Scale. Operating Temp : 0 to 45 °C. Connector Type: Phono Jack 3.5. Humidity Non-condensing: 0-99% RH. OEM Equipment: Analytical Industries – AII-3000-AD Analytical... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0-100%)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-10 % CO2 & 0-25 % O2, 0-15 % CO2 & 0-25 % O2, 0-30 % CO2 & 0-25 % O2Device type StationaryGasflow Forced flowTechnology NDIR, ZirconiaApprovals NoOutput signal RS232, 0/4-20 mA, 0-10 VDCFeatures NDIR, ZirconiaSupplier Angst+Pfister Sensors... [See More]
- Electrical Outputs: Voltage; Current
from CO2Meter.com
The O2-A1 Alphasense Oxygen sensor is designed to provide engineers, scientists and students an accurate and reliable way to measure up to 25% oxygen levels by volume. This sensor is a low cost, industrial safe, oxygen module designed to last one year. Features. Electrochemical Sensor measures up to... [See More]
- Electrical Outputs: Voltage
- Measurement Type: %Volume
- Number of Gases Monitored: Single
- Gas Types: O2 (0-20.9% oxygen)
from InfraTec GmbH
LIM-032 Features: Dual channel. TO39 housing. Small chip size. Beamsplitter. JFET. Voltage mode. PYROMID ® Multi Channel Detectors. Dual, triple, quad and eight channel infrared detectors for gas analysis and flame detection sensors where more than one element or event is to be detected. [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -40 to 185
from ABB Measurement & Analytics
The Advance Optima process gas analyzers have a modular design that offers a long-term security in your investment. Analyzer modules can be freely combined into tailor-made solutions and upgraded or extended with new features at any time. Remote modules are easily attached and centrally operated. [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Multi
- Sensor Technology: Electrochemical; Flame Ionization Detector
- Measurement Type: Trace
from Dexter Research Center, Inc.
Features. A 2 x 16 staggered element silicon-based thermopile array. Each active area is 0.05mm x 0.65mm with a time constant of 7ms and a very low Temperature Coefficient of Responsivity of -0.01%/ Â °C. It is packaged in a 38-pin DIP. Applications. Spectral analysis and line temperature... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from Acme Engineering Products
The Acme Combustible gas sensor/transmitter measures the concentration of the target gas in an enclosed area and produces a proportional analog output signal. The Acme 40-ST Combustible Gas sensor is explosion-proof. The enclosure of the sensor/transmitter is an explosion-proof enclosure. . [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from DigiKey
Alcohol (C2H6O) Sensor 0 V ~ 3.3 V [See More]
- Electrical Outputs: Voltage
- Operating Temperature: 14 to 158
from SST Sensing Ltd.
Details. Industry-leading low power consumption. Typical measurement accuracy of 30ppm. Solid-state LED NDIR sensing technology. Supports UART and I ²C data communication. Fully power-cycling compatible for optimal energy savings. Integrated auto-calibration functionality. Compliant with... [See More]
- Electrical Outputs: Voltage
- Gas Types: CO2 (0 - 2000ppm, 0 - 5000ppm, 0-1%) (0 - 2000ppm, 0 - 5000ppm, 0-1%)
from Electro Optical Components, Inc.
SemeaTech 4S PID Sensor is a simple plug-and-play sensor and able to deliver a dynamic and dependable response to thousands of volatile organic compounds (VOCs) across many diverse applications. The sensor incorporates lamps of exceptional brightness and stability enabling detection of less volatile... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Multi
- Sensor Technology: PID
- Measurement Type: Trace
from Analytical Industries Inc.
Key features. Signal Output: 10-14 mV. Measuring Range: 0-100% O2. Response Time: 13 Seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 2 Pin Female. Oxygen sensor... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0-100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Rugged and stable 0...5% zirconia oxygen sensor module [See More]
- Electrical Outputs: Voltage; Current
from CO2Meter.com
The O2-A2 Alphasense Oxygen Sensor is designed to monitor 25% oxygen levels by volume. The sensor is most sought after as a replacement sensor for handheld gas detectors that use the O2-A2 sensor. Features. Electrochemical Sensor measures up to 25% Oxygen. Barometric Pressure, Temperature and %... [See More]
- Electrical Outputs: Voltage
- Measurement Type: %Volume
- Number of Gases Monitored: Single
- Gas Types: O2 (0-20.9% oxygen)
from InfraTec GmbH
The detectors with the smallest housing size in the miniaturized LRM range are the LRM-102 and LRM-202. Both dual channel detectors are integrated in TO46 housings. Their aperture opening has a size of approximately 6 mm2 each. As a solution e.g. for gas analysis and leakage detection, they can be... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from ABB Measurement & Analytics
EasyLine is both a powerful and affordable line of instruments for the monitoring of gas concentrations in numerous applications. Up to two analyzer modules can be combined in one housing to measure up to five different gases continuously. The advantages to you – EasyLine offers: Proven... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Multi
- Sensor Technology: Electrochemical; Flame Ionization Detector; PID
- Measurement Type: %Volume; Trace
from Dexter Research Center, Inc.
Features. A four-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm x 1.2mm . Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a very short thermal shock response... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 257
from Acme Engineering Products
The Acme GasPost toxic gas sensor/transmitter measures the concentration of the target gas in an enclosed area and produces a proportional analog output signal. . The 4-20mA transmitter is designed for standard 2-wire loop-powered operation where the output is supplied via the same pair of... [See More]
- Electrical Outputs: Voltage; Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Multi
- Sensor Technology: Electrochemical
- Measurement Type: Trace
from DigiKey
Methane Sensor 2.5 V ~ 4 V [See More]
- Electrical Outputs: Voltage
- Gas Types: Methane (CH4) / Natural Gas
from SST Sensing Ltd.
Details. Engineered for full immersion into the gas sample stream. Minimal cross-sensitivity to other gases. Fully RoHS & REACH compliant. Operates reliably in both vacuum conditions and high oxygen concentrations. Direct interface with microcontrollers, including Arduino and Raspberry Pi. [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -22 to 140
- Gas Types: O2 (0—25% O2)
from Electro Optical Components, Inc.
Electro Optical Components introduces a series of revolutionary high sensitivity, high performance, low power &, small size gas imaging detector modules. Because they operate at higher temperatures (140K vs 77K) than other cooled MID IR Arrays, they last longer. They can detect more than 400... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: Leakage
from Analytical Industries Inc.
Key features. Signal Output: 4-8 mV. Measuring Range: 0-100% O2. Response Time: 13 Seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 2 Pin Female. Oxygen sensor for... [See More]
- Electrical Outputs: Voltage
- Operating Humidity: 0 to 99
- Gas Types: O2 (0-100% O2)
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-5 %Device type StationaryGasflow Forced flowTechnology ZirconiaApprovals NoOutput signal 0/4-20 mA, 0-10 VDC, RS232, RS485Features Zirconia, long lifetime, integrated flow cellSupplier Angst+Pfister Sensors and Power [See More]
- Electrical Outputs: Voltage; Current
from CO2Meter.com
Cubic's PM1.0, PM2.5, and PM10 combined Particulate Matter Sensors deliver fast, accurate and stable performance at an incredibly low price. They are designed to be used stand-alone or as the foundation of an OEM indoor air quality PM detector. Features. Advanced laser scattering technology. [See More]
- Electrical Outputs: Voltage
- Measurement Type: %Volume
- Number of Gases Monitored: Single
- Gas Types: (0~5,000μg/m³)
from InfraTec GmbH
Single channel; TO39 housing; small chip size; JFET; voltage mode; DLaTGS - Deuterated L-Alanine doped TriGlycine Sulphate; short thermal time constant, metal black coating; [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 131
from ABB Measurement & Analytics
The specialists for hazardous locations. The EL3060 series is compactly built and especially designed for hazardous areas. The gas analyzer is made up of the flameproof enclosed control unit which can also contain one analyzer. The infrared photometer is built into a separate flameproof enclosure... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared; PID
- Measurement Type: %Volume; Trace
from Dexter Research Center, Inc.
Features. A four-channel silicon-based thermopile detector in a TO-8 package. Each active area size is 1.5mm x 1.5mm. Affordable four-channel design with strong output and a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a very short thermal shock response to... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Sensor 2.5 V ~ 4 V [See More]
- Electrical Outputs: Voltage
from SST Sensing Ltd.
Details. The interface delivers three simultaneous outputs: RS232 (standard serial voltage levels). RS485 (Modbus RTU) for multi-sensor communication on a shared bus. 0 –5V analog output for basic oxygen measurement. Operating temperature range: 0 °C to +50 °C. Compatible with... [See More]
- Electrical Outputs: Voltage
- Operating Temperature: 32 to 122
from Analytical Industries Inc.
Key features. Measuring Range: 0-100%. Signal Output: 3.8 - 5.5 mV. Response Time T90: 9 sec. Accuracy: +/-2% of Full Scale. Operating Temp : 0 to 45 °C. Connector Type: Phono Jack 3.5. Humidity Non-condensing: 0-99% RH. OEM Equipment: Analytical Industries – GPR-2000 Analytical... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0-100%)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-25 %Device type Portable, StationaryGasflow Flow by diffusion, Forced flowTechnology ZirconiaApprovals NoOutput signal Rx/Tx, 3.3 V TTL levelFeatures Zirconia, long lifetimeSupplier Angst+Pfister Sensors and Power [See More]
- Electrical Outputs: Voltage
from CO2Meter.com
The SBH-2A Cubic NDIR 2% Propane Gas Sensor detects 0-2% levels of C3H8 propane gas in ambient environments. Features. Measures 0 to 2% Propane by volume. Full range linearized and digital signal output. Shock-resistant, long-life NDIR sensor. Reference channel for self-compensation. Build-in... [See More]
- Electrical Outputs: Voltage
- Measurement Type: %Volume
- Number of Gases Monitored: Single
- Gas Types: (0-2% Vol)
from InfraTec GmbH
LIE-312 Features: Single channel. TO39 housing. Medium chip size. JFET. Voltage mode. Long time constant. Metal black coating. Extended Detectors from InfraTec. Single channel enhanced IR detectors with fast response, extended gain, and/or high modulation frequency range for applications in... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 140
from ABB Measurement & Analytics
The complete solution for kiln and calciner gas exit. The development of the SCK is based on ABB's experience gained from its successful predecessors, of which more than 500 systems have been supplied worldwide. The SCK sampling system is preferably combined with ABB's ACX gas analyzer system for... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical; Flame Ionization Detector
- Gas Types: (Hot Cement Flue Gas)
from Dexter Research Center, Inc.
Features. A four-channel thin-film thermopile in a TO-8 package. Each active area is 2mm x 2mm. Offers the world's highest 4-channel sensitivity with exceptional signal-to-noise performance in a TO-8 package. Internal aperture minimizes channel-to-channel crosstalk while increasing sensitivity. [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Hydrogen Sulfide (H2S) Sensor 2.5 V ~ 4 V [See More]
- Electrical Outputs: Voltage
from SST Sensing Ltd.
Details. Efficient gas sample management with flow-through housing. Minimal interference from other gases. Compliant with RoHS & REACH regulations. Operates seamlessly in vacuum and high-oxygen environments. Compatible with microcontrollers like Arduino and Raspberry Pi. Delivers accurate... [See More]
- Electrical Outputs: Voltage
- Operating Temperature: 50 to 113
- Gas Types: O2 (0—25% O2)
from Analytical Industries Inc.
Key features. Measuring Range: 0-100%. Signal Output: 9.7 - 20.7 mV. Response Time T90: 6 sec. Accuracy: +/-2% of Full Scale. Operating Temp : 0 to 45 °C. Connector Type: Phono Jack 3.5. Humidity Non-condensing: 0-99% RH. OEM Equipment: Analytical Industries – GPR-3500 MO. Overview. All... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0-100%)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-25 %Device type StationaryGasflow Flow by diffusionTechnology ZirconiaApprovals NoOutput signal 0-210 mV log.Features Zirconia, Long lifetimeSupplier Fujikura [See More]
- Electrical Outputs: Voltage
from CO2Meter.com
The SBrH-5A Cubic 5% NDIR Methyl Bromide Gas Sensor by Cubic detects 0-5% levels of CH3Br methyl bromide gas in ambient environments. Features. Measures 0 to 5% Methyl Bromide by Volume. Long-life NDIR sensor. Built-in temperature and humidity compensation. Auto-Baseline calibration can be enabled. [See More]
- Electrical Outputs: Voltage
- Measurement Type: %Volume
- Number of Gases Monitored: Single
- Gas Types: Methane (CH4) / Natural Gas (0-5% Vol)
from InfraTec GmbH
LIM-222 Description: Dual channel. TO39 housing. Small chip size. Thermal compensation. JFET. Voltage mode. Planar Multi Channel Detectors. Detectors for gas analysis and flame detection. Two, three or four spectral channels in one housing. Thermally compensated (optional). With special chip holder... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -40 to 185
from ABB Measurement & Analytics
Continuous Emission Monitoring Solution. World leader in stack gas monitoring systems for more than 40 years and pioneer in FTIR technology, ABB Analytical is offering an inexpensive and forward-looking system with the ACF-NT (former Advance Cemas FTIR) multi-component emission and process... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Multi
- Sensor Technology: FTIR
- Measurement Type: %Volume; Trace; Density
from Dexter Research Center, Inc.
Features. A one-channel compensated thin-film thermopile in a TO-5 package. The active area and compensating element area are 3.16mm x 0.4mm each. Internal aperture minimizes channel-to-channel crosstalk and thus increasing sensitivity. Applications. Industrial and medical monitoring including... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
SCD43-D-R2 CO2 SENSOR I2C, SMD [See More]
- Electrical Outputs: Voltage
- Operating Temperature: 14 to 140
- Gas Types: CO2
from SST Sensing Ltd.
Details. Gas-tight rear design simplifies sample handling. Minimal cross-sensitivity to other gases. Fully RoHS and REACH compliant. Operates in vacuum and high O ₂ environments. Direct interface with microcontrollers (e.g., Arduino, Raspberry Pi). Outputs: %O ₂, ppO ₂,... [See More]
- Electrical Outputs: Voltage
- Operating Temperature: 86 to 140
- Gas Types: O2 (0—25% O2)
from Analytical Industries Inc.
Key features. Measuring Range: 0-100%. Signal Output: 7-13 mV. Response Time T90: 6 sec. Accuracy: +/-2% of Full Scale. Operating Temp : 0 to 45 °C. Connector Type: 3 Pin Molex. Humidity Non-condensing: 0-99% RH. OEM Equipment: Teledyne Viamed R-22A. Overview. The GPR-11-917-M is a galvanic... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0-100% Signal Output: 7-13 mV RT T90: 6 sec Accuracy: +/-2% of FSO Temp : 0 to 45°C Connector Type: 3 Pin Molex Humidity Non-condensing: 0-99% RH)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-25 %Device type StationaryGasflow Flow by diffusionTechnology ZirconiaApprovals NoOutput signal 0-250 mVFeatures Zirconia, Long lifetimeSupplier Fujikura [See More]
- Electrical Outputs: Voltage
from CO2Meter.com
The Zirconia Oxygen Sensor System offers a complete oxygen level measurement solution removing the need for customers to develop their own electronics. It can be used in combustion control systems, coal, oil, gas, biomass and in oxygen generation systems. When connected to the OXY-LC interface... [See More]
- Electrical Outputs: Voltage; Current
- Gas Types: O2 (Oxygen Sensor Module - Zirconia Oxygen Sensor System)
- Number of Gases Monitored: Single
from InfraTec GmbH
As the first representative of the LRM series, the LRM-254 marks the starting point for all other models. The miniaturized four channel detector in a TO39 housing with an square aperture opening of 5 mm has the typical features of this product series: cap with central window, channel filters inside... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from Dexter Research Center, Inc.
Features. A one-channel compensated thin-film thermopile in a TO-8 package. The active area and compensating element area are 4mm x 0.6mm each. Offers high output with very good signal-to-noise ratio. Internal aperture minimizes channel-to-channel crosstalk increasing sensitivity. Applications. [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Carbon Monoxide (CO) Sensor 0 V ~ 3 V [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -40 to 122
- Gas Types: CO
from Analytical Industries Inc.
Key features. Signal Output: 25 ±2 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS). Humidity Range: Non-condensing, 0-99% RH. Oxygen sensor for use in: KISS Sport. BMR-500 Rebreather. Biomarine MK15/15/5 Rebreather. [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 75-95 %Device type StationaryGasflow Flow by diffusionTechnology ZirconiaApprovals NoOutput signal 1235 to 2669 mVFeatures Zirconia, long lifetimeSupplier Fujikura [See More]
- Electrical Outputs: Voltage
from InfraTec GmbH
LIE-202 Features: Single channel. TO18 housing. Small chip size. JFET. Voltage mode. Single Channel Pyroelectric Detector. Infrared detectors for gas analysis, flame detection and radiometry in TO18 or TO39 packages. Housing types TO18 and TO39. Voltage or current mode. Signal processing with JFET... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from Dexter Research Center, Inc.
Features. A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 1.2mm x 1.2mm in a TO-5 package. Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a very... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 257
from DigiKey
Carbon Dioxide (CO2) Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -4 to 131
- Gas Types: CO2
from Analytical Industries Inc.
Key features. Signal Output: 23-29 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 2 Pin Female MolexOxygen sensor... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Electrochemical sensor for medical applications. Oxygen (0,...,100%). mV output signall - 9-13 mV in air. Repsonse time (T90) less than 7 seconds. Lifetime more than 4 years. RoHS compliant [See More]
- Electrical Outputs: Voltage
from Dexter Research Center, Inc.
Features. A single-channel silicon-based thermopile that delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C with a high output voltage and a quick time constant of 38ms. This Low-cost detector comes in a TO-5 package. This detector has a very short thermal shock response... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Carbon Dioxide (CO2), Methane Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -4 to 131
- Gas Types: CO2; Methane (CH4) / Natural Gas
from Analytical Industries Inc.
Key features. Signal Output: 23-29 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 2 Pin Female MolexOxygen sensor... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
The P-41AGW series has many features that make it attractive for a lot of applications including additive manufacturing and many more: 1) Measurement range 1...10000 ppm. 2) No cross influence from reducing gases and other gases. 3) high signal stability (temperature compensated) and high signal... [See More]
- Electrical Outputs: Voltage
from Dexter Research Center, Inc.
Features. A single-channel silicon-based thermopile in a LCC package for surface mount assembly in a small active area of 0.61mm x 0.61mm. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a very... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Carbon Dioxide (CO2), Methane Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -4 to 131
- Gas Types: CO2; Methane (CH4) / Natural Gas
from Analytical Industries Inc.
Key features. Signal Output: 7-13 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 3 Pin Female MolexOxygen sensor for... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
The PAROX 1200 paramagnetic oxygen gas sensor module is designed for incorporation in your analyzer-systems with very low cross-sensitivity, long lifetime and very stable long term performance. The PAROX 1200 (earlier known as OXYPA) paramagnetic oxygen sensor is internally heated (55 °C) and... [See More]
- Electrical Outputs: Voltage; Current
from Dexter Research Center, Inc.
Features. A single-channel silicon-based thermopile provides lowest cost solutions in a small active area of 0.61mm x 0.61mm in a TO-5 package. Time constant of 18ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ °C. This detector has a... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Carbon Dioxide (CO2), Methane Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -4 to 131
- Gas Types: CO2; Methane (CH4) / Natural Gas
from Analytical Industries Inc.
Key features. Signal Output: 8-12 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 2 Pin MolexOxygen sensor for use... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type SensorMeasuring range 0-100 %Device type Portable, StationaryGasflow Flow by diffusion, Forced flowTechnology ElectrochemicalApprovals NoOutput signal 10 +/- 5 mV in airFeatures Expected operating life > 60 month in normal operation, very low cross sensitivity and fast responding... [See More]
- Electrical Outputs: Voltage
from Dexter Research Center, Inc.
Features. A ten-channel thin-film thermopile in a TO-8 package. Each active area is 3.16mm x 0.4mm and offers low noise voltage. Internal aperture minimizes channel-to-channel crosstalk while increasing sensitivity. Applications. The perfect single package choice for analyzing multiple anesthetic... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Hydrocarbons Sensor Voltage [See More]
- Electrical Outputs: Voltage
from Analytical Industries Inc.
Key features. Signal Output: 9-14 mV. Measuring Range: 0-100% O2. Response Time: 6 Seconds to reach 90% of the final value. Linearity: ±2% of Full Scale (FS). Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 3.5 Phono JackOxygen sensor for use in: De-Ox. Dive Rite VTI /... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0-100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Dexter Research Center, Inc.
Features. A thin film-based single element thermopile detector that offers the world's highest sensitivity in a TO-5 package. Dare to compare. Low noise voltage of 12.8nV/ √Hz. Applications. Excellent for gas analysis, fire detection and non-contact temperature measurement. Benefit. Extremely... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Hydrocarbons Sensor Voltage [See More]
- Electrical Outputs: Voltage
from Analytical Industries Inc.
Key features. Signal Output: 8.5-14 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: Phono Power JackOxygen sensor for... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Dexter Research Center, Inc.
Features. A three-channel compensated (6 element) thin-film thermopile in a TO-8 package. Each active area is 3.16mm x 0.4mm. Offers thermal compensation to minimize effect of sudden ambient temperature change. Internal aperture minimizes channel-to-channel crosstalk while increasing sensitivity. [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Hydrocarbons Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Gas Types: Hydrocarbons
from Analytical Industries Inc.
Key features. Signal Output: 23-27 mV. Measuring Range: 0-100% O2. Response Time: 6 Seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 3.5 Phono Jack ConnectorOEM... [See More]
- Electrical Outputs: Voltage
- Operating Temperature: 32 to 113
- Gas Types: O2 (0-100% O2)
- Operating Humidity: 0 to 99
from Dexter Research Center, Inc.
Features. A three-channel thin-film thermopile in a TO-8 package. Each symmetrically positioned active area is 3.16mm x 0.4mm. Offers low noise output and internal aperture minimizing channel-to-channel crosstalk while increasing sensitivity. Applications. Gas analysis for automotive, environmental... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Hydrocarbons Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Gas Types: (Light Gases)
from Analytical Industries Inc.
Key features. Signal Output: 11-13mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±2% Full Scale (FS). Humidity Range: Non-condensing, 0-99% RH. Electrical Connection: 90 º SMB Female on 5.25 ² cable. Replacement sensor for:... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Dexter Research Center, Inc.
Features. A two-channel or a one-channel compensated thin-film thermopile in a TO-8 package. Each active area is 4mm x 0.6mm. Offers high output with excellent signal-to-noise ratio. An internal aperture minimizes channel-to-channel crosstalk increasing sensitivity. Applications. Gas analysis,... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Hydrocarbons Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -40 to 131
from Analytical Industries Inc.
Key features. Signal Output: 8.5-14 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 3 Pin MolexOxygen sensor for use... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Dexter Research Center, Inc.
Features. A two-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm x 1.2mm . Time constant of 25ms with Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/ Â °C. This detector has a very short thermal shock... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 257
from DigiKey
Hydrocarbons Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -4 to 140
from Analytical Industries Inc.
Key features. Signal Output: 23-27 mV. Measuring Range: 0-100% O2. Response Time: 6 seconds to reach 90% of the final value. Accuracy: ±1% Full Scale (FS), ±5% FS over the operating range. Humidity Range: Non-condensing, 0-99% RH. Electrical Connections: 3 Pin MolexOxygen sensor for use... [See More]
- Electrical Outputs: Voltage
- Gas Types: O2 (0 - 100% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Dexter Research Center, Inc.
Features. A two-channel silicon-based thermopile detector in a TO-5 package. Each small active area size is 0.61mm x 0.61mm. This is our lowest-cost and fastest time constant two-channel detector. It delivers a time constant of 18ms with Nitrogen encapsulation gas combined with a very low... [See More]
- Electrical Outputs: Voltage
- Features: Temperature
- Sensor Technology: Semiconductor
- Operating Temperature: -58 to 212
from DigiKey
Flammable Gas Sensor Voltage [See More]
- Electrical Outputs: Voltage
- Operating Temperature: -40 to 140
from Clark Solutions
The FYA600-Series sensors are ideal for monitoring the amount of gases in the ambient environment. The measurement of these critical gases is useful for monitoring air quality, particularly in environmental chambers and incubators in which the development of organisms is critical. Standard sensor... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: %Volume
from H2scan, Corp.
H2scan's HY-OPTIMA ™ 700B series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA ™ 700B series is a solid-state sensor that is configured to operate in process gas streams with temperatures... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Semiconductor; Solid State Sensor
- Measurement Type: %Volume
from Honeywell Analytics, Inc.
The Sensepoint XCD transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres, indoors and outdoors —and is marked by installation ease and flexibility, user-friendly operation and cost-effective gas monitoring. Sensepoint... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic; Electrochemical
- Measurement Type: %LEL or %LFL; %Volume; Trace
from Hydrogen Sense Technology Co., Ltd
The H2Sense 8 series Hydrogen Sensor is specially designed for Hydrogen measurement applications in Fuel Cell sector. Our patent solid state palladium alloy hydrogen thin film sensor technology is hydrogen specific and does not have cross sensitivity with other gas like CO,CH & NOx. Besides... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Solid State Palladium Alloy Hydrogen Thin Film Sensor
- Measurement Type: %Volume
from E+E Elektronik
The EE820 measures reliably CO2 concentration in harsh, demanding applications. A multipoint CO2 and temperature factory adjustment leads to excellent accuracy over the entire temperature working range. The EE820 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Vaisala
For %-level measurements in life science incubators, cold storage facilities and all demanding applications. The Vaisala CARBOCAP ® Carbon Dioxide Probe GMP251 is an intelligent, stand-alone, %-level probe for measuring CO2 in life science incubators, cold storage facilities, fruit and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: %Volume
from Sensirion
SCD30 - Sensor Module for HVAC and Indoor Air Quality Applications. CMOSens ® Technology for IR detection enables highly accurate carbon dioxide measurement at a competitive price. Along with the NDIR measurement technology for CO2 detection, a best-in-class Sensirion humidity and temperature... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: CMOSens® Technology
- Measurement Type: Trace
from Belimo Americas
Duct sensor CO2 , AC/DC 24 V, output DC 0 …5 /10 V adjustable [See More]
- Electrical Outputs: Voltage
- Gas Types: CO2 (0 to 2000 ppm)
from First Sensor AG
The XYA oxygen sensors are based on a special zirconium dioxide (ZrO2) technology to enable highly stable and accurate measurements from 0...100 %Vol. oxygen concentration. These sensors are non-consumptive and feature easy calibration in ambient air. Typical applications include medical technology,... [See More]
- Electrical Outputs: Voltage; Current (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Zirconium Dioxide (ZrO2)
- Measurement Type: %Volume
from MO2 Inc.
The DHP is available with SDI-12 or RS-485 outputs. The DHP-485 can be configured with 0-5 volt or 4-20mA output as well as having remote access capability. The DHP is capable of being interfaced with most commercial data loggers, PLCs and samplers. Typical applications for the DHP are leak... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Fiber Optic Chemical Sensor
- Measurement Type: Trace; Leakage
from Axetris AG
The LGD F200 instrument series is based on a contact-less, near-infrared absorption measurement of the target gas. The systems are self-contained, ready-to-use OEM modules, using a flow-through cell set-up forextractive measurements. [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Tunable Diode Laser Spectrometer
- Measurement Type: Trace; Leakage
from Conspec Controls Inc.
CONSPEC Controls Multi-Channel Controller is a microprocessor-based multi-analog input controller. The P2259/60 was designed to be an independent stand-alone controller but can integrate into any type of data acquisition system. The Controller can provide up to eight channels of remote monitoring... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: %LEL or %LFL; %Volume; Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. Infrared carbon dioxide CO2 sensor CM1106H-NS can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology (NDIR). It is widely used in ventilation system, air conditioner, air purifier, IAQ monitor, agriculture, plant cultivation and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Delphian Corporation
Delphian makes two types of sensors for combustible hydrocarbon detection: the model 201G, catalytic combustion type sensor, and the model 201B thermal conductivity type sensor. All sensors are temsted for span in methane and offset in air only to make sure they meet controlled performance standards... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic Combustion
- Measurement Type: %Volume
from H2scan, Corp.
H2scan's HY-ALERTA ™ 600B/610B Fixed Area Hydrogen Monitors will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen's low... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Hydrogen-Specific Sensor Technology
- Measurement Type: %Volume; Leakage
from Honeywell Analytics, Inc.
UL certified, explosion-proof flammable gas detectors with high temperature version certified to 150 °C. The Model 705 high temperature sensor has been specifically designed for the detection of combustible gases in high temperature hazardous area locations. Typical applications include turbine... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from E+E Elektronik
EE8915 measures reliably CO2 concentration in harsh environment and complies with the relevant railway standards. Active pressure and temperature compensation with on-board sensors leads to best CO2 measurement accuracy independent of temperature, altitude or weather conditions. The EE8915... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Vaisala
For ppm-level measurements in agriculture, refrigeration, demanding HVAC, and for plant growth manufacturers. The Vaisala CARBOCAP ® Carbon Dioxide Probe GMP252 is an intelligent, stand-alone, ppm-level probe. It's intended for measuring CO2 in agriculture, refrigeration, greenhouses, demanding... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: Trace
from Sensirion
For HVAC and Air Quality Applications. With this new particulate matter sensor, Sensirion expands its range of environmental sensing solutions and opens up a new dimension in indoor and outdoor air quality applications. The SPS30 particulate matter (PM) sensor represents a new technological... [See More]
- Electrical Outputs: Voltage
- Measurement Type: Density
- Sensor Technology: Laser Scattering
- Operating Temperature: 14 to 140
from Axetris AG
The LGD F200 instrument series is based on a contact-less, near-infrared absorption measurement of the target gas. The systems are self-contained, ready-to-use OEMmodules, using a flow-through cell set-up for extractive measurements. The slightly bigger LGD F200 (H) version features optional cell... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Tunable Diode Laser Spectrometer
- Measurement Type: Trace; Leakage
from Conspec Controls Inc.
CONSPEC's Single Channel Controllers are single point monitoring and control processors, which are housed in a NEMA 4-4X weatherproof non-metallic enclosure and are designed to monitor and display any voltage or current input signal from any instrument, including CONSPEC's EZ-CAL Toxic and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: %LEL or %LFL; %Volume; Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. Dual beam with better accuracy and high stability NDIR CO2 sensor module CM1107 is mainly used to detect CO2 concentration by adopting non-dispersive infrared (NDIR) technology. It is widely used for home HVAC system, HVAC controller, air conditioner, agricultural cultivation, food... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Honeywell Analytics, Inc.
Acts as the nerve center of a modular gas detection network by providing continuous monitoring of up to 96 sensors. The Manning AirAlertTM 96d multichannel gas monitoring system is designed for installation and operational simplicity for continuous monitoring and control of toxic gases, combustible... [See More]
- Electrical Outputs: Voltage; Switch or Relay
- Number of Gases Monitored: Multi
- Sensor Technology: Electrochemical
- Gas Types: Combustible; CO2; CO; Cl2; H2; O2
from E+E Elektronik
The EE850 is a 3 in 1 duct mounted transmitter ideal for demand controlled ventilation and building automation. It combines CO2, humidity and temperature in an innovative and functional enclosure. The EE850 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing effects,... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Vaisala
For Demanding Measurements. The Vaisala CARBOCAP ® Carbon Dioxide Probe GMP343 is an accurate and rugged probe-type instrument for ecological measurements. Typical applications include CO2 soil respiration, ambient CO2 monitoring, plant growth chambers, and OEM applications. The GMP343... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: Trace
from Conspec Controls Inc.
CONSPEC Controls Multi-Channel Controller is a microprocessor-based multi-analog input controller. The P2260 was designed to be an independent stand-alone controller but can integrate into any type of data acquisition system. The Controller can provide up to sixteen channels of remote monitoring and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: %LEL or %LFL; %Volume; Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. CM1106SL-N is super low power consumption, high performance NDIR CO2 sensor, which can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared (NDIR) technology. It is ideally suited for battery power device applied in HVAC industry and greenhouse,... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Honeywell Analytics, Inc.
Sensepoint XCD RFD is your most flexible, practical choice for remote flammable gas monitoring in Class I Division 1 areas. XCD RFD adds safety, productivity and cost efficiency to an operation by extending intelligent, simplified gas monitoring to hard-to-reach areas. XCD ’s inherent... [See More]
- Electrical Outputs: Voltage; Current
- Measurement Type: %LEL or %LFL
- Number of Gases Monitored: Multi
- Gas Types: Hydrocarbons (20-100%)
from E+E Elektronik
The EE872 reliably measures CO2 concentration up to 5 % (50 000 ppm) in agriculture, life stock barns, hatchers, incubators, green houses or outdoors. The active pressure and temperature compensation with on-board sensors leads to best CO2 measurement accuracy independently of the altitude or... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Vaisala
For Smart Control of Biogas Quality. Get more value out of waste by improved decision-making, and by reducing your operating costs. Vaisala CARBOCAP ® MGP261 Multigas Probe for Methane, Carbon Dioxide and Humidity helps in improving your process and in protecting the Combined Heat and Power... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: %Volume
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. Infrared carbon dioxide CO2 sensor CM1106SH can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology (NDIR). It is widely used in ventilation system, air conditioner, air purifier, IAQ monitor, agriculture, plant cultivation and cold... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature)
from Honeywell Analytics, Inc.
Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring. Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I,... [See More]
- Electrical Outputs: Voltage; Current
- Measurement Type: %Volume; Trace
- Number of Gases Monitored: Multi
- Gas Types: Toxic; NH3 (0-50 PPM); CO (0-200 PPM); Cl2 (0-5 PPM); H2S (0-50 PPM); NO (0-100 PPM); NO2 (0-10 PPM); O2 (0-25%); SO2 (0-15 PPM)
from Vaisala
For Bio-Decontamination Processes. The Vaisala PEROXCAP ® Hydrogen Peroxide, Humidity, and Temperature Probe HPP270 series probes HPP271 and HPP272 are designed for demanding hydrogen peroxide bio-decontamination where repeatable, stable, and accurate measurement is essential. HPP270 series... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: PEROXCAP®
- Measurement Type: Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. AM1008W is an ultra-thin indoor air quality sensor with highly integrated laser particle sensor, NDIR CO2 sensor, temperature sensor and humidity sensor, which can real-time output digital measurement data. The thinnest size. And the VOC sensor integrated can be customized. FEATURES. [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared; Semiconductor; Laser Scattering
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Honeywell Analytics, Inc.
ATEX certified flammable, toxic and Oxygen gas detectors offering a low cost solution to hazardous area monitoring. The Sensepoint range of flammable, toxic and Oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Installation in potentially... [See More]
- Electrical Outputs: Voltage
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL; Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. CM1106-C series is a single beam NDIR CO2 sensor, based on non-dispersive infrared (NDIR) technology with independent intellectual property, which can detect CO2 concentration of indoor air. With high accuracy, long term stability, small size, it is widely used for ventilation system,... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume