Analog Current Gas Sensors
from Dynament
Dynament ’s FGD10A Flameproof Fixed Gas Detectors are specifically designed for use in potentially explosive atmospheres, where the risk of an incendive spark from electrical equipment could trigger an explosion. In such hazardous environments, commonly found in industries like oil, gas, and... [See More]
- Electrical Outputs: Current
- Gas Types: Toxic; Combustible; CO2; Hydrocarbons; H2; O2
- Sensor Technology: NDIR Infrared, Electrochemical or Pellistor
- Features: Hazardous Environment
from CO2Meter.com
The Zirconia Oxygen Sensor System offers a complete oxygen level measurement solution removing the need for customers to develop their own electronics. It can be used in combustion control systems, coal, oil, gas, biomass and in oxygen generation systems. When connected to the OXY-LC interface... [See More]
- Electrical Outputs: Voltage; Current
- Gas Types: O2 (Oxygen Sensor Module - Zirconia Oxygen Sensor System)
- Number of Gases Monitored: Single
from Sensore Electronic GmbH
The Sensore SO-D0-XXX-AXXXC M16 Thread Oxygen Sensor is a stainless steel, threaded solution designed for accurate and stable oxygen measurement across a wide range of industries, including medical, laboratory, food processing, measuring instrumentation, security technology, and the electrical... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (10 ppm to 96% oxygen)
- Sensor Technology: Zirconium Dioxide (ZrO₂) sensor technology
- Operating Temperature: 158
from InfraTec GmbH
The LRM-278 is the world's first detector of its kind to combine eight measurement channels in a TO8 housing with a diameter of 15.2 millimeters and operates in current mode. It also incorporates a temperature sensor. Measuring the temperature inside the detector, for example, provides the option of... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from MSA Safety
Every feature of the PrimaX IR Gas Transmitter is designed with reliability in mind to withstand the most challenging environmental conditions through out the product ’s life. MSA ’s PrimaX IR Gas Transmitter offers LEL (Lower Explosive Limit) combustible gas detection through a patented... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL
from ABB Measurement & Analytics
The sensor, based on a zirconium oxide cell, is mounted at the tip of the probe that is inserted in the flue duct. The resulting direct, in situ measurement provides accurate and rapid oxygen reading for combustion control optimization and emissions monitoring. [See More]
- Electrical Outputs: Current
- Operating Temperature: -4 to 158
- Features: Hazardous Environment
- Operating Humidity: 0 to 95
from Acme Engineering Products
The Acme Combustible gas sensor/transmitter measures the concentration of the target gas in an enclosed area and produces a proportional analog output signal. The Acme 40-ST Combustible Gas sensor is explosion-proof. The enclosure of the sensor/transmitter is an explosion-proof enclosure. . [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from Analytical Industries Inc.
Key features. Measuring range - 0-25% O2. Signal Output (Air) - 35-55 µA. Sensitivity - 1.67-2.63 µA/% O2. Response Time (T90) - 13 Seconds. Humidity non-condensing - 0-99% RH. Electrical Connection - PCB 2 Ring. Replacement Sensor For: Southland Sensing PO2-160. Oxygen Sensor For Use In:... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0-25% O2)
- Sensor Technology: Electrochemical; Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-10 % CO2 & 0-25 % O2, 0-15 % CO2 & 0-25 % O2, 0-30 % CO2 & 0-25 % O2Device type StationaryGasflow Forced flowTechnology NDIR, ZirconiaApprovals NoOutput signal RS232, 0/4-20 mA, 0-10 VDCFeatures NDIR, ZirconiaSupplier Angst+Pfister Sensors... [See More]
- Electrical Outputs: Voltage; Current
from DigiKey
Carbon Monoxide (CO) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 131
- Gas Types: CO
from Dynament
Dynament ’s Flameproof Fixed Gas Detectors are specifically designed for use in potentially explosive atmospheres where the risk of ignition from electrical equipment sparks is a critical safety concern. These detectors comply with requirements to enclose electrical components within... [See More]
- Electrical Outputs: Current
- Gas Types: Toxic; Combustible; CO2; Hydrocarbons; H2; O2
- Sensor Technology: NDIR Infrared, Electrochemical or Pellistor
- Features: Hazardous Environment
from Sensore Electronic GmbH
The M18 ALU Sinter Cap SO ‑D3 is a high-performance oxygen sensor featuring zirconium dioxide technology for precise O ₂ measurement in industrial applications. Its durable design ensures reliable performance, fast response, and long service life. The SO-D3 series ensures reliable... [See More]
- Electrical Outputs: Current
- Gas Types: O2
- Sensor Technology: zirconium dioxide technology
- Operating Temperature: 158
from InfraTec GmbH
Dual channel; TO46 housing; small chip size; thermal compensation; OpAmp; single supply; current mode; feedback 100 GOhm; [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from MSA Safety
The IR400 Infrared (IR) Point Detector is a hydrocarbon gas detector that continuously monitors combustible gases and vapors within the lower explosive limit (LEL) and provides alarm indication. It features an industry-leading response time of ≤ 3 seconds, even with a splash guard installed. [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL; %Volume
from ABB Measurement & Analytics
Accurate measurement of both oxygen and COe is important for the safe, reliable and efficient operation of industrial combustion plant. – carbon monoxide detector. – flue gas. – combustion analysis. – combustion analyzer. [See More]
- Electrical Outputs: Current
- Features: Hazardous Environment
- Gas Types: O2 (Carbon Monoxide Equivalent (COe))
- Operating Humidity: 0 to 95
from Acme Engineering Products
The Acme REF-IR-ST Sensor/Transmitter is designed to detect the presence of refrigerant leaks in enclosed areas. The REF-IR-ST series employs a high-precision NDIR sensor ideal for gas-specific and accurate measurements of the most commercially used refrigerants. With its 1PPM resolution, 0-1000PPM... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: Trace
from Analytical Industries Inc.
Key features. Measuring range - 0-25% O2. Signal Output (Air) - 35-55 µA. Sensitivity - 1.67-2.63 µA/% O2. Response Time (T90) - 13 Seconds. Humidity non-condensing - 0-99% RH. Electrical Connection - 4 pin Male mates with MACB-4-FP-2M-B. Industrial oxygen sensor for use in Analytical... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0-25% O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Simultaneous detection of oxygen, temperature & humidity. Output signal digital UART (modbus protocol) or analog 4-20 mA. Power saving sleeping mode for IoT and battery solutions. No warm up time. No temperature and humidity in fluence. Fast response time. Small size, no orientation effect [See More]
- Electrical Outputs: Current
from DigiKey
Carbon Monoxide (CO) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 131
- Gas Types: CO
from Dynament
The Dynament FGD4 series safe area gas detectors are designed for use in non-hazardous environments and operate on a DC power supply (8 –24V). These loop-powered gas detectors transmit gas concentration levels via a standard two-wire 4 –20mA current loop, making them compatible with a... [See More]
- Electrical Outputs: Current
- Gas Types: CO2
- Sensor Technology: Infrared; Electrochemical or NDIR Infrared
- Features: Hazardous Environment
from Sensore Electronic GmbH
The Sensore SO-A0-XXX Micro Oxygen Sensor utilises advanced Zirconium Dioxide (ZrO ₂) technology to deliver precise, stable oxygen concentration measurements across a wide range of industrial and scientific applications. This compact sensor is engineered for reliability and accuracy, making it... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (100 ppm to 96% oxygen)
- Sensor Technology: Zirconium Dioxide (ZrO₂) technology
- Operating Temperature: 482
from InfraTec GmbH
LIM-262 Description: Dual channel. TO39 housing. Small chip size. Thermal compensation. OpAmp. Current mode. Feedback 100 GOhm. Planar Multi Channel Detectors. Detectors for gas analysis and flame detection. Two, three or four spectral channels in one housing. Thermally compensated (optional). With... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -40 to 185
from MSA Safety
Senscient open path gas detector ensures best in class false alarm rejection. The Senscient ELDS laser-based open path gas detector is available for a wide range of toxic and flammable gases. The Senscient ELDS uses 'SimuGas' self-testing to eliminate employees entering hazardous areas for gas... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single; Multi (optional feature)
- Sensor Technology: Enhanced Laser Diode Spectroscopy
- Measurement Type: %Volume
from Acme Engineering Products
The Acme GasPost toxic gas sensor/transmitter measures the concentration of the target gas in an enclosed area and produces a proportional analog output signal. . The 4-20mA transmitter is designed for standard 2-wire loop-powered operation where the output is supplied via the same pair of... [See More]
- Electrical Outputs: Voltage; Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Multi
- Sensor Technology: Electrochemical
- Measurement Type: Trace
from Analytical Industries Inc.
Key features. Measuring Range: 0 - 10,000 PPM O2. Signal Output: 240 - 350 uA. Response Time T90: 6 sec. Accuracy: +/-1% of Full Scale. Operating Temp : 0 to 45 °C. Connector Type: 4 pin round connector. Humidity Non-condensing: 0-99% RH. OEM Equipment: Analytical Industries – GPR-1900D. [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0 - 10,000 PPM O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Rugged and stable 0...5% zirconia oxygen sensor module [See More]
- Electrical Outputs: Voltage; Current
from DigiKey
Alcohol (C2H6O) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 131
from Sensore Electronic GmbH
The Sensore SO-B0-xxx Mini Oxygen Sensor (Board Mount) is engineered for direct PCB integration and offers precise oxygen measurement for a wide range of industrial and commercial applications. Its low surface temperature ( <70 °C) makes it suitable for compact system designs requiring... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (10 ppm to 96% oxygen)
- Sensor Technology: Zirconium Dioxide (ZrO₂) technology
- Operating Temperature: 158
from InfraTec GmbH
LIM-054 Features: Quad channel. TO8 housing. Small chip size. Beamsplitter. OpAmp. Current mode. Feedback 22 GOhm. PYROMID ® Multi Channel Detectors. Dual, triple, quad and eight channel infrared detectors for gas analysis and flame detection sensors where more than one element or event is to be... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -40 to 185
from MSA Safety
The IR5500 is an open path infrared (IR) gas detector that continuously monitors for flammable gas leaks over large open areas. It monitors in both the LEL-m and ppm-m ranges to detect both small and large leaks. The IR5500 offers the benefits of early detection with its high sensitivity to gas... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL; %Volume; Trace
from Acme Engineering Products
The ACME Wireless MultiSet series is a microprocessor-based multipoint multigas wireless detection and control system that can be used with the wireless CO and NO2 GasPost sensors. The communication between the Control Panel and the remote GasPost sensor/transmitters is accomplished through a 900... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic (optional feature); Electrochemical (optional feature); Infrared (optional feature)
- Measurement Type: Trace
from Analytical Industries Inc.
Key features. Measuring range 0-10,000 ppm O2. Signal output (10,000ppm) - 28-45 µA. Signal output (air) - 590-950 µA. Response time (T90) - 3 seconds. Electrical connections - 2 ring PCB. Flow rate 0-2.5 LPM. OEM Equipment: Southland Sensing TO2-233. Overview. This electrochemical... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0-10,000 ppm O2)
- Sensor Technology: Electrochemical; Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-5 %Device type StationaryGasflow Forced flowTechnology ZirconiaApprovals NoOutput signal 0/4-20 mA, 0-10 VDC, RS232, RS485Features Zirconia, long lifetime, integrated flow cellSupplier Angst+Pfister Sensors and Power [See More]
- Electrical Outputs: Voltage; Current
from DigiKey
Alcohol (C2H6O) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 131
from Sensore Electronic GmbH
The Sensore SO-E2-xxx-D040C Mini Oxygen Sensor with Cable is designed for accurate and reliable oxygen concentration measurement across a wide range of applications, including medical devices such as oxygen concentrators, laboratory instrumentation, and food processing systems. Utilising advanced... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (100 ppm to 96% oxygen)
- Sensor Technology: Zirconium Dioxide (ZrO₂) sensor technology
- Operating Temperature: 158
from InfraTec GmbH
An enormous field of view (FOV) distinguishes the LRM 244 from other detectors of the LRM series. The extremely large, symmetrical field of view of the detector of more than 90 degrees enables flames to be detected within the greatest possible angular range. In addition to this, pyro elements, each... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from Analytical Industries Inc.
Key features. Measuring range - 0-10,000 ppm O2. Signal Output (10,000ppm) - 28-45 µA. Signal Output (Air) - 590-950 µA. Flow Rate - 0-2.5 LPM. Response Time (T90) - 3 Seconds. Electrical Connection - PCB 2 ring. Industrial oxygen sensor for use in Analytical Industries - GPR-1600. [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0-10,000 ppm O2)
- Sensor Technology: Electrochemical; Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-25 %Device type StationaryGasflow Flow by diffusionTechnology ZirconiaApprovals NoOutput signal 4-20 mAFeatures Zirconia, long lifetimeSupplier Fujikura [See More]
- Electrical Outputs: Current
from DigiKey
Hydrogen Sulfide (H2S) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 131
from Sensore Electronic GmbH
The Sensore SO-E61 series delivers precise oxygen measurement from 100 ppm to 96 % O ₂ in a compact, robust design. Using proven zirconium dioxide (ZrO ₂) technology, these sensors provide fast response, stable performance, and long life with minimal influence from temperature, pressure,... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (100 ppm – 96 % O₂)
- Sensor Technology: zirconium dioxide (ZrO₂) technology
- Operating Temperature: 158
from InfraTec GmbH
As a specialist in flame detection technology the LRM-274 expands the range of detectors, that are characterized by a field of view wider than 90 ˚. The low-power detector requires only one unipolar supply voltage and is particularly suitable for operation in industrial fire protection and... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from Analytical Industries Inc.
Key features. Measuring Range: 0 - 10,000 PPM O2. Signal Output: 550 - 1050 uA. Response Time T90: 3 sec. Accuracy: +/-1% of Full Scale. Operating Temp : 0 to 45 °C. Connector Type: 4 pin Molex. Humidity Non-condensing: 0-99% RH. OEM Equipment: Analytical Industries – GPR-1800 Liquid... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0 - 10,000 PPM O2)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-25 %Device type StationaryGasflow Flow by diffusionTechnology ZirconiaApprovals NoOutput signal 4-20 mAFeatures Zirconia, long lifetime, electronic board and sensor connected via a cableSupplier Angst+Pfister Sensors and Power [See More]
- Electrical Outputs: Current
from DigiKey
Hydrogen Sulfide (H2S) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 131
from Sensore Electronic GmbH
Introducing the SENSORE SO-E3-xxx Mini Oxygen Sensor with Hose Connection, a compact zirconium dioxide oxygen sensor designed for PCB mounting across a diverse range of industries. From medical applications such as oxygen concentrators to laboratory equipment, food processing, and more, this... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (100 ppm to 96% Oxygen)
- Sensor Technology: Zirconium Dioxide (ZrO2) technology
- Operating Temperature: 158
from InfraTec GmbH
On the market there are only a few miniaturized multi-channel detectors operating in current mode. Therefore the LRM-284 is definitely something special. The current mode of the single supply detector is enabled by two double-operational amplifiers. This detector allows the design of an analyzer... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from Analytical Industries Inc.
Key features. Measuring range - 0-10,000 ppm O2. Signal Output (10,000ppm) - 28-45 µA. Signal Output (Air) - 590-950 µA. Sensitivity - 2.8-4.5 nA/ppm O2. Response Time (T90) - 3 Seconds. Electrical Connection - 4 pin Molex. Industrial oxygen sensor for use in Analytical Industries -... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0-10,000 ppm O2)
- Sensor Technology: Electrochemical; Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-25 %Device type StationaryGasflow Forced flowTechnology ZirconiaApprovals NoOutput signal 4-20 mAFeatures Zirconia, long lifetime, integrated flow cellSupplier Angst+Pfister Sensors and Power [See More]
- Electrical Outputs: Current
from DigiKey
Ozone (O3) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 122
from Sensore Electronic GmbH
The SO-D1-XXX-AXXXC M10 Thread Oxygen Sensor utilizes advanced zirconium dioxide (ZrO ₂) technology to deliver precise oxygen concentration measurements across various applications, including medical devices, laboratory instrumentation, and food processing systems. Its high accuracy and long... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (10 ppm to 96% Oxygen)
- Sensor Technology: zirconium dioxide (ZrO₂) technology
from InfraTec GmbH
LIE-200 Features: Single channel. TO18 housing. Small chip size. JFET. Current mode. Feedback 1 GOhm. Single Channel Pyroelectric Detector. Infrared detectors for gas analysis, flame detection and radiometry in TO18 or TO39 packages. Housing types TO18 and TO39. Voltage or current mode. Signal... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Operating Temperature: -13 to 185
from Analytical Industries Inc.
Key features. Measuring range - 0-10,000 ppm O2. Signal Output (10,000ppm) - 28-45 µA. Signal Output (Air) - 590-950 µA. Flow Rate - 0-2.5 LPM. Response Time (T90) - 3 Seconds. Electrical Connection - 4 pin Molex. Industrial oxygen sensor for use in Analytical Industries GPR-1500 GB remote... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0-10,000 ppm O2)
- Sensor Technology: Electrochemical; Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
Product type Gas sensor moduleMeasuring range 0-1000 ppmDevice type StationaryGasflow Forced flowTechnology ZirconiaApprovals NoOutput signal 4-20 mAFeatures Zirconia, electronic board and sensor connected via a cableSupplier Angst+Pfister Sensors and Power [See More]
- Electrical Outputs: Current
from DigiKey
Nitrogen Dioxide (NO2) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -40 to 122
from Sensore Electronic GmbH
The Sensore SO-D2-XXX-AXXXC M16 Thread Oxygen Sensor (Aluminium Housing) is a robust and versatile solution for accurate oxygen measurement across medical, laboratory, food processing, and industrial applications. Designed for direct in-situ installation via an M16 threaded connection, the sensor... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (10 ppm to 96% oxygen)
- Sensor Technology: Zirconium Dioxide (ZrO₂) technology
- Operating Temperature: 158
from Analytical Industries Inc.
Key features. Measuring Range: 0-100%. Signal Output: 295-625 uA. Response Time T90: 7 seconds. Accuracy: ±2% of full scale. Operating Temp : 0 to 45 °C. Connector Type: 2 Ring Gold Disk. Humidity Non-condensing: 0 –99% RH, non-condensing. OEM Equipment: AMI P2 Sensor. GE Sensing... [See More]
- Electrical Outputs: Current
- Operating Temperature: 32 to 113
- Gas Types: O2 (0-100%)
- Operating Humidity: 0 to 99
from Angst+Pfister Sensors and Power
Product type SensorMeasuring range 0-25 %Device type Portable, StationaryGasflow Flow by diffusion, Forced flowTechnology ZirconiaApprovals NoOutput signal 70 +/-10 µA in airFeatures Zirconia, long lifetime, fast response timeSupplier Fujikura [See More]
- Electrical Outputs: Current
from DigiKey
Nitrogen Dioxide (NO2) Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -40 to 122
from Analytical Industries Inc.
Key features. Measuring Range: 0-100%. Signal Output: 235-355 uA. Response Time T90: 13 seconds. Accuracy: ±2% of full scale. Operating Temp : 0 to 45 °C. Connector Type: 2 Ring Gold Disk. Humidity Non-condensing: 0 –99% RH, non-condensing. OEM Equipment: AMI P2 Sensor. Teledyne B-3... [See More]
- Electrical Outputs: Current
- Gas Types: O2 (0-100%)
- Sensor Technology: Echem
- Operating Temperature: 32 to 113
from Angst+Pfister Sensors and Power
The PAROX 1200 paramagnetic oxygen gas sensor module is designed for incorporation in your analyzer-systems with very low cross-sensitivity, long lifetime and very stable long term performance. The PAROX 1200 (earlier known as OXYPA) paramagnetic oxygen sensor is internally heated (55 °C) and... [See More]
- Electrical Outputs: Voltage; Current
from DigiKey
Sulfur Dioxide Sensor Current [See More]
- Electrical Outputs: Current
- Operating Temperature: -22 to 122
- Gas Types: SO2
from Vaisala
For CO ₂ Incubators. The Vaisala CARBOCAP ® Carbon Dioxide Probe GMP231 is designed to provide incubator manufacturers with accurate and reliable carbon dioxide measurements and sterilization durability at high temperatures, up to 180 °C. The GMP231 probe is based on Vaisala ’s... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: %Volume
from Det-Tronics
The PIRDuct "DuctWatch" combustible IR gas detector is specially designed to deliver reliable gas detection in enclosed airhandling ductwork applications. Safety engineers have long been aware that duct air monitoring provides the ability to maximize protection of confined spaces in challenging... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %Volume
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. Infrared carbon dioxide CO2 sensor CM1106H-NS can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology (NDIR). It is widely used in ventilation system, air conditioner, air purifier, IAQ monitor, agriculture, plant cultivation and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Trafag Inc.
Main Features. Continuous digital or analogue output signal. Usable for SF6 trend analysis. Wide density range. Additional output of sensor temperature (digital version). Extremely drift free signal. Outdoor application without additional protection [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Gas Types: SF6 (0...60 kg SF6/m3)
from Emerson Automation Solutions – Rosemount
This multi-component QCL represents the next generation of gas analyzers and sensors, with the ability to measure up to 20 gases and an interchangeable modular configuration for up to 9 lasers. An embedded ARM processor gives fully autonomous intelligent operation. Key Features/Benefits: Measure up... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: %Volume; Trace
from Delphian Corporation
The CommonSensor allows the user control over the cost of sensor use. By having the ability to replace sensor elements and flame arrestors, instead of the whole sensor, the user can keep the system operational with less expenditure for spares and labor. [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from Conspec Controls Inc.
CONSPEC's CN Series is an economical choice for toxic, combustible, and Oxygen gas monitoring. The CN Series is a simple and "smart" gas detector. An industry standard 4-20mA Analog output signal can be connected to any existing PLC, DCS, or EMS system. A simplified calibration procedure allows for... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: Trace
from Global Detection Systems Corp.
The GDS-IR Infrared Gas Sensor uses proven, reliable infrared sensing technology to detect dangerous levels of carbon dioxide or explosive levels of methane, propane and other hydrocarbons. Designed for especially harsh environments, the GDS-IR is virtually maintenance-free and immune to poisoning... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume (optional feature)
from Teledyne Monitor Labs, Inc.
The SM425 is ideally suited for both. compliance monitoring of diluent gas. (Environmental Compliance) and Oxygen. monitoring for combustion and process. control applications. The SM425. offers state of the art oxygen analysis. and a rugged industrial design. Operators and engineers will appreciate. [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Fuel Cell
- Measurement Type: %Volume
from H2scan, Corp.
H2scan's HY-OPTIMA ™ 700B series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA ™ 700B series is a solid-state sensor that is configured to operate in process gas streams with temperatures... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Semiconductor; Solid State Sensor
- Measurement Type: %Volume
from Analytical Systems Int’l. Keco
The petrochemical, gas processing, and gas pipeline industry has required an accurate and dependable, low maintenance and cost-effective CO2 analyzer for quality and process control purposes. Analytical Systems International has met these requirements with their proven microprocessor based non... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Edgetech Instruments Inc.
4-20 mA Loop Powered Two Wire Oxygen Transmitter. The Edgetech Instruments Model OxyTrans is an easy to use, accurate and economical way to measure Oxygen at trace and % levels. A simple display and one point calibration allows for a quick start of the instrument. Measuring Range. The unit will... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical; Micro-Fuel Cell
- Measurement Type: Trace
from Axetris AG
The LGD F200 instrument series is based on a contact-less, near-infrared absorption measurement of the target gas. The systems are self-contained, ready-to-use OEM modules, using a flow-through cell set-up forextractive measurements. [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Tunable Diode Laser Spectrometer
- Measurement Type: Trace; Leakage
from MO2 Inc.
The DHP is available with SDI-12 or RS-485 outputs. The DHP-485 can be configured with 0-5 volt or 4-20mA output as well as having remote access capability. The DHP is capable of being interfaced with most commercial data loggers, PLCs and samplers. Typical applications for the DHP are leak... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Fiber Optic Chemical Sensor
- Measurement Type: Trace; Leakage
from Honeywell Analytics, Inc.
The Sensepoint XCD transmitter provides comprehensive monitoring of combustible, toxic and Oxygen gas hazards in potentially explosive atmospheres, indoors and outdoors —and is marked by installation ease and flexibility, user-friendly operation and cost-effective gas monitoring. Sensepoint... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic; Electrochemical
- Measurement Type: %LEL or %LFL; %Volume; Trace
from Belimo Americas
Duct sensor CO2, DC 24 V, output 4 …20 mA [See More]
- Electrical Outputs: Current
- Gas Types: CO2 (0 to 2000 ppm)
from Pem-Tech, Inc.
Features. RS-485 MODBUS Serial Output. 4-20mA Analog Output. 12-28 VDC Operation. Automated Non-Intrusive Calibration. Fully Adjustable Alarm Relay. Lower wiring costs. Description. Ultra 1000 series is a microprocessor based addressable sensor for toxic gas detection. The self- contained sensor... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: %LEL or %LFL; Trace
from RainWise, Inc.
Rainwise offers customized turnkey weather monitoring solution. [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: %LEL or %LFL; Trace
from E+E Elektronik
The EE820 measures reliably CO2 concentration in harsh, demanding applications. A multipoint CO2 and temperature factory adjustment leads to excellent accuracy over the entire temperature working range. The EE820 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Senscient Inc.
Reliable, rapid detectionof methane concentrations in pre-combustion ventilation systems at 0.5 to 5.0 meters. 100% continuous measurement of normal gas levels present in the combustion stream and rapid, accurate detection of breakthrough gas levels for optimum safety in combustion operations. Fully... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Enhanced Laser Diode Spectroscopy
- Measurement Type: %LEL or %LFL; Trace; Leakage; Signature
from Vaisala
For %-level measurements in life science incubators, cold storage facilities and all demanding applications. The Vaisala CARBOCAP ® Carbon Dioxide Probe GMP251 is an intelligent, stand-alone, %-level probe for measuring CO2 in life science incubators, cold storage facilities, fruit and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: %Volume
from Det-Tronics
The PointWatch Eclipse ® Model PIRECL IR Carbon Dioxide Gas Detector detects carbon dioxide in the harshest environments. The Eclipse is an ideal solution for monitoring CO2 suppression cylinder storage, skids for CO2 detection of enhanced oil recovery sites. Other user benefits include:... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %Volume; Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. Dual beam with better accuracy and high stability NDIR CO2 sensor module CM1107 is mainly used to detect CO2 concentration by adopting non-dispersive infrared (NDIR) technology. It is widely used for home HVAC system, HVAC controller, air conditioner, agricultural cultivation, food... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Emerson Automation Solutions – Rosemount
This hybrid system is the most cost effective solution to meet the measurement needs in marine applications. Key Features/Benefits: Measure up to 10 gases simultaneously. Ambient environments of up to 70 °C (158 °F) and gas temperatures of 190 °C (374 °F). Single and dual path... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: %Volume; Trace
from Delphian Corporation
Combustible CommonSensor, catalytic BASEEFA approved, aluminum [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from Conspec Controls Inc.
CONSPEC's CX Series is an economical choice for toxic, combustible, and Oxygen gas monitoring. The CX Series is a simple and "smart" gas detector designed for use in hazardous or classified locations. An industry standard 4-20mA Analog output signal can be connected to any existing PLC, DCS, or EMS... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: Trace
from H2scan, Corp.
H2scan's HY-ALERTA ™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen's low... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Hydrogen-Specific Sensor Technology
- Measurement Type: %Volume; Leakage
from Analytical Systems Int’l. Keco
The petrochemical, gas processing, & gas pipeline industry has for many years required an accurate, dependable, low maintenance, and cost effective sulfur analyzer for quality and process control purposes. With over twenty years of experience in developing and manufacturing sulfur analyzers and... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Lead Acetate Tape/Photodiode-LED
- Measurement Type: Trace
from Edgetech Instruments Inc.
4-20 mA Loop Powered Two Wire Oxygen Transmitter. The Edgetech Instruments Model OxyTrans is an easy to use, accurate and economical way to measure Oxygen at trace and % levels. A simple display and one point calibration allows for a quick start of the instrument. Measuring Range. The unit will... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical; Special Fuel Cell
- Measurement Type: %Volume; Trace
from Axetris AG
The LGD F200 instrument series is based on a contact-less, near-infrared absorption measurement of the target gas. The systems are self-contained, ready-to-use OEMmodules, using a flow-through cell set-up for extractive measurements. The slightly bigger LGD F200 (H) version features optional cell... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Tunable Diode Laser Spectrometer
- Measurement Type: Trace; Leakage
from Honeywell Analytics, Inc.
Highest performance fixed flammable and toxic gas detector with a choice of communication outputs, accessories and installation flexibility. Apex takes the best elements of gas detection design and combining them into one unit. Apex provides the highest performance, installation flexibility, a wide... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic; Electrochemical
- Measurement Type: %LEL or %LFL; %Volume; Trace
from Pem-Tech, Inc.
Ultra 1000 series is a microprocessor based addressable sensor for detection of combustible gases. The self- contained sensor features user friendly interface and menu driven calibration procedure and configuration. The complete sensor consists of a stainless steel sensor head assembly, a user... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from E+E Elektronik
EE8915 measures reliably CO2 concentration in harsh environment and complies with the relevant railway standards. Active pressure and temperature compensation with on-board sensors leads to best CO2 measurement accuracy independent of temperature, altitude or weather conditions. The EE8915... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Vaisala
For ppm-level measurements in agriculture, refrigeration, demanding HVAC, and for plant growth manufacturers. The Vaisala CARBOCAP ® Carbon Dioxide Probe GMP252 is an intelligent, stand-alone, ppm-level probe. It's intended for measuring CO2 in agriculture, refrigeration, greenhouses, demanding... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: Trace
from Det-Tronics
The Det-Tronics Nanotechnology Metal Oxide Semiconductor (NTMOS) gas detector delivers fast and repeatable H2S detection in extreme temperature and humidity applications where electrochemical sensing technologies are not preferred. The NTMOS H2S detector uses the latest nanotechnology to ensure... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. CM1106SL-N is super low power consumption, high performance NDIR CO2 sensor, which can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared (NDIR) technology. It is ideally suited for battery power device applied in HVAC industry and greenhouse,... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Conspec Controls Inc.
CONSPEC Controls Multi-Channel Controller is a microprocessor-based multi-analog input controller. The P2259/60 was designed to be an independent stand-alone controller but can integrate into any type of data acquisition system. The Controller can provide up to eight channels of remote monitoring... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: %LEL or %LFL; %Volume; Trace
from H2scan, Corp.
H2scan's 2620 Explosion Proof Area Hydrogen Monitor provides hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen's low flammability limit. The... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Hydrogen-Specific Sensor Technology
- Measurement Type: %Volume; Leakage
from Analytical Systems Int’l. Keco
The petrochemical, gas processing, and gas pipeline industry has required an accurate and dependable, low maintenance and cost-effective H2S analyzer for quality and process control purposes. With over thirty years of experience in developing and manufacturing gas analyzers and associated parts and... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Lead Acetate Tape/Photodiode-LED
- Measurement Type: Trace
from Edgetech Instruments Inc.
The Edgetech Instruments Model OxyTrans-PSS is a portable oxygen transmitter that is fast responding, accurate and is capable of measuring oxygen at trace or percent levels. The OxyTrans-PSS has the capability of measuring oxygen between 0 - 10,000 ppm or 0-25 % and offers ease of operation with a... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical; Micro-Fuel Cell
- Measurement Type: %Volume; Trace
from Honeywell Analytics, Inc.
2-Channel Gas Detection System with Configurable Control, Flexible Application And User-Friendly Operation. The HA20 digital gas controller provides simultaneous display and alarm functions for two sensor transmitters, along with user-friendly operation and configuration flexibility. The HA20... [See More]
- Electrical Outputs: Current
- Measurement Type: %LEL or %LFL; %Volume; Trace; Leakage
- Number of Gases Monitored: Multi
- Operating Temperature: -13 to 122
from Pem-Tech, Inc.
Model PT205 sensor is designed to detect combustible hydrocarbons vapors in air and provides an analog output signal. PT205 uses catalytic beads sensor to detect combustible vapors in % LEL. The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from E+E Elektronik
The EE850 is a 3 in 1 duct mounted transmitter ideal for demand controlled ventilation and building automation. It combines CO2, humidity and temperature in an innovative and functional enclosure. The EE850 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing effects,... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Vaisala
For Demanding Measurements. The Vaisala CARBOCAP ® Carbon Dioxide Probe GMP343 is an accurate and rugged probe-type instrument for ecological measurements. Typical applications include CO2 soil respiration, ambient CO2 monitoring, plant growth chambers, and OEM applications. The GMP343... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared; Vaisala CARBOCAP®
- Measurement Type: Trace
from Det-Tronics
Det-Tronics offers a line-of-sight gas detector for measurement of hydrocarbon vapors in the lower explosive limit per distance (LFL-meter) detection range. Ideally suited for open path gas detection applications in oil, gas, and petrochemical facilities, the Open Path Eclipse provides a number of... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. Infrared carbon dioxide CO2 sensor CM1106SH can be used to detect CO2 concentration of indoor air by adopting advanced non-dispersive infrared technology (NDIR). It is widely used in ventilation system, air conditioner, air purifier, IAQ monitor, agriculture, plant cultivation and cold... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature)
from Conspec Controls Inc.
CONSPEC's Single Channel Controllers are single point monitoring and control processors, which are housed in a NEMA 4-4X weatherproof non-metallic enclosure and are designed to monitor and display any voltage or current input signal from any instrument, including CONSPEC's EZ-CAL Toxic and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: %LEL or %LFL; %Volume; Trace
from H2scan, Corp.
H2scan's HY-ALERTA ™ 600B/610B Fixed Area Hydrogen Monitors will provide hydrogen-specific leak detection and measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5% hydrogen by volume, a range representing 10% to 125% of hydrogen's low... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Hydrogen-Specific Sensor Technology
- Measurement Type: %Volume; Leakage
from Analytical Systems Int’l. Keco
The 150 series analyzer monitor is a completely portable H2S analyzer monitor or in-line process featuring a cost-effective analysis method for process control, air quality and product quality purposes. In addition, this analyzer is accurate, dependable, and low maintenance. The microprocessor-based... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Lead Acetate Tape/Photodiode-LED
- Measurement Type: Trace
from Honeywell Analytics, Inc.
4-Channel Gas Detection System with Configurable Control, Flexible Application And User-Friendly Operation. The HA40 digital gas controller provides simultaneous display and alarm functions for four sensor transmitters, along with user-friendly operation and configuration flexibility. The HA40... [See More]
- Electrical Outputs: Current
- Measurement Type: %LEL or %LFL; %Volume; Trace; Leakage
- Number of Gases Monitored: Multi
- Operating Temperature: -13 to 122
from Pem-Tech, Inc.
Model PT295-LEL is a microprocessor-based sensor designed to combustible hydrocarbons in % volume level. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas. The complete sensor consists of a stainless steel sensor head assembly, a user... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from E+E Elektronik
The EE872 reliably measures CO2 concentration up to 5 % (50 000 ppm) in agriculture, life stock barns, hatchers, incubators, green houses or outdoors. The active pressure and temperature compensation with on-board sensors leads to best CO2 measurement accuracy independently of the altitude or... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: Trace
from Vaisala
For Bio-Decontamination Processes. The Vaisala PEROXCAP ® Hydrogen Peroxide, Humidity, and Temperature Probe HPP270 series probes HPP271 and HPP272 are designed for demanding hydrogen peroxide bio-decontamination where repeatable, stable, and accurate measurement is essential. HPP270 series... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: PEROXCAP®
- Measurement Type: Trace
from Det-Tronics
The Det-Tronics GT3000 line of electrochemical fixed-point toxic-gas detectors provides continuous monitoring of the atmosphere for potentially hazardous toxic gas leaks or oxygen depletion. The GT3000 family currently includes sensors that detect each of the following gases (additional gases added... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Electrochemical
- Measurement Type: %Volume; Trace
from Cubic Sensor and Instrument Co.,Ltd.
With the most popular NDIR technology, the SRH Series infrared carbon dioxide sensor has long service life, steady performance, high precision and need less maintenance, which is widely used for carbon dioxide gas leakage alarming, CO2 incubator, greenhouse, environmental monitoring, etc. [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %Volume; Trace
from Conspec Controls Inc.
CONSPEC Controls Multi-Channel Controller is a microprocessor-based multi-analog input controller. The P2260 was designed to be an independent stand-alone controller but can integrate into any type of data acquisition system. The Controller can provide up to sixteen channels of remote monitoring and... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic; Electrochemical; Infrared; PID; Thermal Conductivity
- Measurement Type: %LEL or %LFL; %Volume; Trace
from H2scan, Corp.
H2scan's HY-OPTIMA ™ 1700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA ™ 1700 series is an ATEX certified Intrinsically Safe (IS) device that incorporates our patented solid-state... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Semiconductor; Solid State Sensor
- Measurement Type: %Volume
from Analytical Systems Int’l. Keco
The petrochemical, gas processing, and gas pipeline industry has required an accurate, dependable, low maintenance, and cost-effective sulfur analyzer for quality and process control purposes. With over twenty-five years of experience in developing and manufacturing sulfur analyzers and associated... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Lead Acetate Tape/Photodiode-LED
- Measurement Type: Trace
from Honeywell Analytics, Inc.
The Honeywell Analytics HA71 16 Channel Digital Gas Controller provides simultaneous display and alarm functions for up to 16 input variables. The HA71 can expand with up to ten additional HA71 units to provide up to 160 points of gas detection. A graphic LCD displays monitored data as trends, bar... [See More]
- Electrical Outputs: Current
- Measurement Type: %LEL or %LFL; %Volume; Trace; Leakage
- Number of Gases Monitored: Multi
- Operating Temperature: -13 to 140
from Pem-Tech, Inc.
Model PT395-LEL is a microprocessor-based sensor designed to combustible hydrocarbons in % volume level. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas. The complete sensor consists of a stainless steel sensor head assembly, a user... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Catalytic
- Measurement Type: %LEL or %LFL
from Cubic Sensor and Instrument Co.,Ltd.
Miniature NDIR methane gas sensor adopts advanced non-dispersive technology to detect and monitor CH4 concentration. It is with a heated infrared source inside a small chamber, in this case, the inside temperature of the gas sensor is much higher than the outside which can avoid condensing events... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %Volume
from Analytical Systems Int’l. Keco
This product is specific to samples in amine. The principle of operation requires a continuous free flowing liquid sample into a heated oven where the Sample Transfer Stripper (S.T.S) unit separates the liquids from the H2S gas sample. An H2S free air or nitrogen carrier then sweeps the H2S gas... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: PID; Simple Transfer Stripper (Patented)
- Measurement Type: Trace
from Honeywell Analytics, Inc.
The GM-JR is an innovative stand-alone or "signal feed-through" readout/alarm unit that can be configured in a variety of ways to solve many refrigeration-gas concentration and alarm needs at an affordable price. The readout provides a calibrated 20-segment LED bargraph, alarm and fault LEDs, plus a... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Electrochemical
- Measurement Type: %LEL or %LFL
from Pem-Tech, Inc.
Model PT395-H2S is a microprocessor-based sensor designed to detect hydrogen sulfide in parts per million (ppm) level. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas. The complete sensor consists of a stainless steel sensor head... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: Trace
from Cubic Sensor and Instrument Co.,Ltd.
Miniature NDIR C3H8 sensor adopts NDIR technology to detect C3H8 concentration in serve industrial applications, which can be integrated in safety and alarming devices, for environmental monitoring, gas drainage monitoring, chemical, petroleum, metallurgy, oil depots, liquefied gas stations, paint... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %Volume
from Analytical Systems Int’l. Keco
The petrochemical, gas processing, and gas pipeline industry has required an accurate and dependable, low maintenance and cost-effective H2S analyzer for quality and process control purposes. With over thirty years of experience in developing and manufacturing gas analyzers and associated parts and... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Lead Acetate Tape/Photodiode-LED
- Measurement Type: Trace
from Honeywell Analytics, Inc.
World renowned infrared open path flammable gas detector offering unrivalled performance and sensitivity. The Searchline Excel is the World ’s best selling infrared open path gas detector with over 6,000 units installed in challenging applications throughout industry. From the Arctic Circle to... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL; Leakage
from Pem-Tech, Inc.
Model PT205 sensor is designed to detect Hydrogen Sulfide in air and provides an analog output signal. PT205 uses electrochemical cell technology to detect H2S in parts per million (ppm). The complete sensor consists of a stainless steel sensor head assembly, a user connection board and a... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: Trace
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. AM1008W is an ultra-thin indoor air quality sensor with highly integrated laser particle sensor, NDIR CO2 sensor, temperature sensor and humidity sensor, which can real-time output digital measurement data. The thinnest size. And the VOC sensor integrated can be customized. FEATURES. [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Multi
- Sensor Technology: Infrared; Semiconductor; Laser Scattering
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Analytical Systems Int’l. Keco
The pipeline, geothermal, paper mill, municipal sewage, drilling, & personnel protection industries has for many years needed a dependable, efficient, and cost effective trend H2S analyzer for quality and process control purposes. Now, Analytical Systems Intl. has met these requirements with a... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: Trace
from Honeywell Analytics, Inc.
Take advantage of HART communication added to the proven performance of the market-leading hydrocarbon point infrared gas detector. With over 40 years experience in the design, manufacture, installation and maintenance of point infrared gas detection, Honeywell Analytics currently has a worldwide... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL
from Pem-Tech, Inc.
Ultra 1000-IR series is a microprocessor based sensor for detection of combustible gases using Infrared sensor technology. The self- contained sensor features user friendly interface and menu driven calibration procedure and configuration. Ultra 1000-IR uses NDIR (Non Dispersive Infrared) technique... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL
from Cubic Sensor and Instrument Co.,Ltd.
DESCRIPTION. CM1106-C series is a single beam NDIR CO2 sensor, based on non-dispersive infrared (NDIR) technology with independent intellectual property, which can detect CO2 concentration of indoor air. With high accuracy, long term stability, small size, it is widely used for ventilation system,... [See More]
- Electrical Outputs: Voltage; Current
- Number of Gases Monitored: Single
- Sensor Technology: Infrared
- Measurement Type: %LEL or %LFL (optional feature); %Volume
from Analytical Systems Int’l. Keco
The regulated d.c. power supply provides a constant standing voltage. The gas diffuses through a porous filter and contacts the surface of the sensor element. A change in resistance occurs that is proportional to the concentration at gas applied. This signal is then amplified and sent to the... [See More]
- Electrical Outputs: Current
- Number of Gases Monitored: Multi
- Sensor Technology: Catalytic; Electrochemical
- Measurement Type: %LEL or %LFL
from Honeywell Analytics, Inc.
Sensepoint XCD RFD is your most flexible, practical choice for remote flammable gas monitoring in Class I Division 1 areas. XCD RFD adds safety, productivity and cost efficiency to an operation by extending intelligent, simplified gas monitoring to hard-to-reach areas. XCD ’s inherent... [See More]
- Electrical Outputs: Voltage; Current
- Measurement Type: %LEL or %LFL
- Number of Gases Monitored: Multi
- Gas Types: Hydrocarbons (20-100%)
from Pem-Tech, Inc.
Model PT295 is a microprocessor-based sensor for toxic gas detection in parts per million (ppm) level. The unit features easy one-man calibration initiated by simply activating a magnetic switch and applying the gas. The complete sensor consists of a stainless steel sensor head assembly, a user... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: %LEL or %LFL (optional feature); Trace (optional feature)
from Analytical Systems Int’l. Keco
The petrochemical, gas processing, and gas pipeline industry has required an accurate, dependable, low maintenance, and cost-effective sulfur analyzer for quality and process control purposes. With over twenty-five years of experience in developing and manufacturing sulfur analyzers and associated... [See More]
- Electrical Outputs: Current; Switch or Relay (optional feature)
- Number of Gases Monitored: Single
- Sensor Technology: Lead Acetate Tape/Photodiode-LED
- Measurement Type: Trace
from Honeywell Analytics, Inc.
Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring. Sensepoint XCD RTD from Honeywell Analytics makes it easy on your maintenance team, time and budget when faced with the challenge of monitoring toxic gases in Class I,... [See More]
- Electrical Outputs: Voltage; Current
- Measurement Type: %Volume; Trace
- Number of Gases Monitored: Multi
- Gas Types: Toxic; NH3 (0-50 PPM); CO (0-200 PPM); Cl2 (0-5 PPM); H2S (0-50 PPM); NO (0-100 PPM); NO2 (0-10 PPM); O2 (0-25%); SO2 (0-15 PPM)
from Pem-Tech, Inc.
Features. Microprocessor based modular design. Electrochemical Sensor Technology. Industry standard 4-20mA output. Field adjustable Alarm level. Single point Non-Intrusive calibration. Bright 3 digit LED display. Displays gas concentration in ppm, calibration prompts and sensor fault codes. Suitable... [See More]
- Electrical Outputs: Current; Switch or Relay
- Number of Gases Monitored: Single
- Sensor Technology: Electrochemical
- Measurement Type: %LEL or %LFL; Trace