Analog Current Output pH Instruments

17 Results
Analyzers for Dissolved Oxygen -- AX468
from ABB Measurement & Analytics

AX400 Analyzers incorporate the latest technology providing highly reliable, flexible, feature-packed devices that satisfy a diverse range of process monitoring and control applications. The complete range encompasses solutions for pH/Redox (ORP), conductivity and dissolved oxygen. AX48x instruments... [See More]

  • Electrical Output: Analog Current; Switch / Alarm Relay
  • Accuracy: 0.0100
  • pH range: -2 to 16
  • pH Measurement Features: pH Reference Electrode Input; Temperature Measurement
Powerful, Flexible Multi-Parameter Monitor / Controller -- 900M-1C
from Myron L Company

Myron L ® Company ’s new 900 Series Multi-Parameter Monitor / Controllers combine Accuracy, Reliability, Simplicity, and Flexibility. The user intuitive GUI (Graphical User Interface) allows easy and complete programmability of the instrument all from the LCD touch screen. These highly... [See More]

  • Electrical Output: Analog Voltage; Analog Current; Switch / Alarm Relay
  • Accuracy: 0.0100
  • pH range: 0.0 to 14
  • pH Measurement Features: Temperature Measurement
Fluoride analyzer -- Aztec AFM631
from ABB Measurement & Analytics

The Aztec 600 ISE fluoride analyzer measures total solubilized fluoride using a combination fluoride ion-selective electrode. Featuring ABB's intuitive menu-driven software and the robust ISE sensing system with automatic calibration, users benefit from an analyzer that is both simple-to-operate and... [See More]

  • Electrical Output: Analog Current
  • Display Type: Digital
  • Form Factor: Lab / Benchtop
  • User Controls: Digital Front Panel
pH /Redox (ORP) Transmitter -- Endura APA592
from ABB Measurement & Analytics

ABB's Endura family of 24 VDC analytical transmitters are designed for the requirements of industrial customers and are used in measurement and control applications within a broad range of applications including chemical, pulp & paper, mining and petroleum refining. The APA592 transmitter is... [See More]

  • Electrical Output: Analog Current
  • Accuracy: 0.0100
  • pH range: 0.0 to 14
  • pH Measurement Features: Temperature Measurement
PH Meter -- 559634
from Burkert Fluid Control Systems

The Type 8202 is a compact measuring device designed for the measurement of the pH value or redox potential (ORP): - pH value: in clean or contaminated liquids or liquids containing solids, sulphides or proteins. - the redox potential: in clean or contaminated liquids or liquids containing solids,... [See More]

  • Electrical Output: Analog Current
  • ORP Range: -2 to 16
  • Measures ORP: Yes
  • Process Temp: 32 to 122
AMI Deltacon Power -- A-13.441.100
from SWAN Analytical USA, INC.

Two channel electronic transmitter & controller for wall mounting. Features. For simultaneous conductivity measurements before (specific / total conductivity) and after a cation exchanger (acid / cationic conductivity). Measuring range: 0.055 µS/cm to 30 mS. Calculation of pH value and... [See More]

  • Electrical Output: Analog Current
  • Accuracy: -0.0100 to 0.0100
  • pH range: 7.5 to 11.5
  • pH Measurement Features: pH Reference Electrode Input
Multi-Probe pH Data Logging and Analysis of Lactic Acid Bacteria (LAB) Associated with Cultures and Fermented Foods -- iCinac
from KPM Analytics

Multi-Probe pH Data Logging and Analysis of Lactic Acid Bacteria (LAB) Associated with Cultures and Fermented Foods. The iCinac analyzer is the only solution designed specifically to monitor and analyze the acidification activity of lactic ferments in starter, functional, bio-protective, and... [See More]

  • Electrical Output: Analog Voltage; Analog Current
  • Measures ORP: Yes
  • pH Measurement Features: Temperature Measurement
  • Form Factor: Portable
C200 Series Electrochemical Converter -- C210
from optek-Danulat, Inc.

The CONTROL 200 electrochemical converter is designed for continuous monitoring and control of pH and conductivity. The C200 series is available either as a single input (pH or conductivity) or dual input (pH and/or conductivity) converter. Operation and programming is simple, using pushbuttons on... [See More]

  • Electrical Output: Analog Current; Switch / Alarm Relay
  • Number of Control Relays: 3
  • pH Measurement Features: Temperature Measurement
  • Form Factor: Panel
56 Advanced Dual Input Analyzer -- Model 56
from Emerson Automation Solutions – Rosemount

The Model 56 Analyzer offers single or dual sensor input with an unrestricted choice of dual measurement combinations. The high resolution full-color display gives unsurpassed visibility and functionality for liquid analytical instrumentation. High resolution full-color screen: easily viewed process... [See More]

  • Electrical Output: Analog Current
  • Accuracy: 0.0100
  • pH range: 0.0 to 14
  • Measures ORP: Yes
Amperometric Chlorine Analyzer -- 9184 sc
from Hach

Are you looking for accurate, real-time monitoring of chlorine across a wide measurement range? The 9184 sc free chlorine sensor is ideal for drinking water distribution monitoring, chlorination applications, demineralizer systems, wastewater, or cooling water processes due to its 0 to 20 ppm range. [See More]

  • Electrical Output: Analog Current; Switch / Alarm Relay
  • Process Temp: 2 to 45
  • pH range: 4 to 8
  • Form Factor: Panel; Wall Mount
Micro Volume pH Monitor -- UP-100
from HORIBA Instruments, Inc.

Redevelops HORIBA's founding pH measurement technology using new ultra-small capillary electrode. HORIBA's UP-100 affords ultra-low sample consumption of just 500 uL/measurement, enabling continuous pH monitoring for a variety of critical manufacturing processes that include Semiconductor (Cleaning,... [See More]

  • Electrical Output: Analog Current
  • Form Factor: In-situ / Field
  • pH range: 0.0 to 14
  • Display Type: Digital
AMI pH/Redox/Temperature -- A-11.411.100
from SWAN Analytical USA, INC.

Electronic transmitter/controller for wall mounting. Measuring and control transmitter for field installation in aluminum box (IP 66). Dimensions: 180 x 140 x 70 mm. Connections: 2 signal outputs for measured values or continuous control, 2 relays as limit switches or as controllers, 1 alarm relay... [See More]

  • Electrical Output: Analog Current
  • pH Measurement Features: pH Reference Electrode Input
  • pH range: 0.0 to 14
  • Measures ORP: Yes
Intelligent Four-Wire Analyzer -- Model 1056
from Emerson Automation Solutions – Rosemount

The Model 1056 dual-input analyzer offers single or dual sensor input with an unrestricted choice of dual measurements thus reducing the cost per loop and saving panel space. The unit has a choice of HART and Profibus DP digital communications. It features a large back-lit display that has... [See More]

  • Electrical Output: Analog Current
  • Accuracy: 0.0100
  • pH range: 0.0 to 14
  • Measures ORP: Yes
AMU pH/Redox/Temperature -- A-11.431.100
from SWAN Analytical USA, INC.

Electronic transmitter/controller for panel insertion. Measuring and control transmitter for panel installation in a Noryl ® resin enclosure (IP 54). Dimensions: 96 x 96 x 120 mm. Connections: 2 signal outputs for measured values or continuous control, 2 relays as limit switches or as... [See More]

  • Electrical Output: Analog Current
  • pH Measurement Features: pH Reference Electrode Input
  • pH range: 0.0 to 14
  • Measures ORP: Yes
Multi-Parameter Analyzer -- Model 1057
from Emerson Automation Solutions – Rosemount

MULTI-PARAMETER INSTRUMENT – up to three inputs: Choose pH/ORP/ISE or Contacting Conductivity/Resistivity, in any combination. LARGE DISPLAY – easy-to-read process measurements. EASY TO INSTALL – modular boards, removable connectors, easy to wire power, sensors and outputs. [See More]

  • Electrical Output: Analog Current
  • Accuracy: 0.0100
  • pH range: 0.0 to 14
  • pH Measurement Features: pH Reference Electrode Input
Analyzer AMI Codes-II -- A-23.421.001.0
from SWAN Analytical USA, INC.

Colorimetric process analyzer (DPD-method) for measurement and dosing control of disinfectants such as free chlorine, hypochlorus acid, chlorine dioxide, ozone, bromine, iodine and monochloramine. Features. For the continuous online determination of disinfectants based on the DPD colorimetric method... [See More]

  • Electrical Output: Analog Current
  • pH Measurement Features: pH Reference Electrode Input (optional feature)
  • pH range: 2 to 12
  • Process Temp: -22 to 212
Two-Wire Liquid Analytical Transmitter -- Model 1066
from Emerson Automation Solutions – Rosemount

The Model 1066 loop-powered transmitter measures pH, ORP, conductivity, resistivity, oxygen, free chlorine, total chlorine, monochloramine and ozone serving a wide range of liquid analytical applications. Digital communications – HART ® version 7 and FOUNDATION ® fieldbus communication... [See More]

  • Electrical Output: Analog Current
  • Accuracy: 0.0100
  • pH range: 0.0 to 14
  • Measures ORP: Yes