Rod End - Male Force and Load Sensors
Last Updated: April 1, 2025
Description
Rod End - Male Force and Load Sensors are specialized devices designed to measure the force or load applied to them. These sensors are typically integrated into mechanical systems where they can provide precise measurements of the force exerted along their axis.
Working Principle
Rod End - Male Force and Load Sensors operate based on the principle of strain gauges. When a force is applied to the sensor, it causes a deformation that is detected by the strain gauges. These gauges are electrical resistors whose resistance changes proportionally with the applied force. This change in resistance is then converted into an electrical signal, which can be measured and calibrated to determine the exact force or load being applied. These sensors are particularly useful because they provide accurate and reliable measurements, which are crucial for maintaining the performance and safety of mechanical systems.
Applications
Rod End - Male Force and Load Sensors are commonly used in applications where precise force measurement is critical. For example, they are often employed in screw-driven linear actuators to monitor the output load values directly at the point of application. This ensures that the force exerted by the actuator is accurately measured and controlled, which is essential in automated systems where precision is paramount.
Advantages over other Force and Load Sensors
One of the main advantages of Rod End - Male Force and Load Sensors is their ability to be easily retrofitted to existing systems, such as actuators. This flexibility allows them to be integrated into a wide range of applications without significant modifications. Additionally, because they measure force directly at the point of application, they can provide highly accurate readings, often with an accuracy of ±1% when properly aligned.
Limitations
A significant limitation of Rod End - Male Force and Load Sensors is their sensitivity to misalignment. For accurate measurements, the force must be applied axially to the sensor. Any off-axis or transverse forces can lead to incorrect readings and potentially cause permanent damage to the equipment. Additionally, the need to accommodate the added length of the sensor in the system can pose design challenges, and long cables required for connection can become entangled, interfering with system operations.
Considerations
When considering the use of Rod End - Male Force and Load Sensors, several factors should be taken into account. Initial costs can vary depending on the specific requirements of the application, such as the desired accuracy and load capacity. Operating expenses are generally low, but maintenance costs can arise if the sensors are not properly aligned or if cables become damaged. Durability is typically high, provided the sensors are used within their specified limits. Accuracy is a key benefit, but it is contingent on correct installation and alignment. Replacement and maintenance costs can be minimized by ensuring proper installation and regular inspection to prevent misalignment and cable damage.
from Powell Electronics, Inc.
MALE RODEND THREAD1-14 HEAT TR [See More]
- Package: Rod End - Male
from Stellar Technology
• Ranges From. 5K lbs. to 120K lbs. • In-Line Loading. • Small Diameter. • Variety of Thread. Arrangements. From Which To Choose. • 0.20% Accuracy. • Welded Stainless Steel. • -65 °F to 250 °F Operation. • mV/V Output and. Amplified Output Available [See More]
- Package: Rod End - Male
- Accuracy: 0.20
- Force Rating: 5000 to 120000
- Force Measured: Tension
from Interface, Inc. - AZ
Why the Interface series TCN Micro S-Type Load Cell is the best in class: Medical application. Miniature S-Type load cell with male threads. Aluminum construction, RTV sealed. Capacities of 50 & 75 lbf [See More]
- Package: Rod End - Male
- Output: Analog Voltage; 3.0 mV/V
- Force Rating: 50 to 75
- Device: Sensor / Transducer
from Sensor Developments, Inc.
This sensor incorporates a welded diaphragm system that isolates the sensor from extraneous forces and bending moments. The 10254 may be used in tension or compression and is fatigue resistant. [See More]
- Package: Rod End - Male; Rod End - Female
- Output: Analog Voltage
- Force Rating: 1000 to 25000
- Device: Sensor / Transducer
from tecsis LP
Model XLRH is a rod-end load cell designed for in line measurement of tension or compression forces and features a male thread on one end and female threads on the other. The unit is available in sizes from 5" to 22.5" long and covers ranges from 2,000 to 200,000 lbs. The stainless steel Model XLRH... [See More]
- Package: Rod End - Male; Rod End - Female
- Force Measured: Tension; Compression
- Force Rating: 2000 to 200000
- Output: Analog Voltage
from Montalvo Corporation
Not all load cells are created equal. As part of the ES Series of load cells, Dead Shaft/Idler load cells deliver the finest sensitivity in the industry. Accuracy, Precision, Consistency, & Functionality combine to make the most reliable & repeatable tension sensing system available today. [See More]
- Package: Rod End - Male
- Force Measured: Tension
- Force Rating: 25 to 500
- Output: Analog Current
from OMEGA Engineering, Inc.
The LCMUW Series hydrostatically compensated load cell is a unique load cell designed for operation underwater. Applications include dry docks, marine weighing, submerged platforms and industrial weighing applications where pit flooding is common. The all stainless steel construction and rugged... [See More]
- Package: Canister; Rod End - Male
- Accuracy: 0.25
- Force Rating: 100 to 10000
- Force Measured: Tension; Compression
from NOSHOK, Inc.
Features & Benefits. Thin film sensor is laser welded to the deformation body for superior strength and performance. Extremely accurate - with the help of Finite Element Method Analysis, this sensor is able to reach accuracies from 0.2% to 1% Full Scale. Custom-designed to customer... [See More]
- Package: S-beam; Pancake; Donut / Washer; Plate / Platform; Bolt; Link; Miniature; Cantilever; Canister; Load Pin; Rod End - Male; Rod End - Female; Tank Weighing
- Accuracy: 0.20 to 1.00
- Force Rating: 1000 to 100000
- Force Measured: Tension; Compression; Shear
from Stellar Technology
• Compact High Capacity. • Tension / Compression. • High Strength Tool Steel. • 0.25% Accuracy. • -65 ° to 250 ° F Operation. • Environmentally Sealed. • Low Deflection [See More]
- Package: Rod End - Male
- Accuracy: 0.25
- Force Rating: 5000 to 25000
- Force Measured: Tension; Compression
from Interface, Inc. - AZ
Why the Interface series 2120 Rod End is the best in class: Automotive application. Used to measure forces in a shaker table. Custom column style design with rod end bearings. Capacity 200kN. More Information. The 2120 rod end load cell is typically used with actuators where sensitivity to side... [See More]
- Package: Rod End - Male
- Output: Analog Voltage; 2 mV/V
- Force Rating: 44960
- Device: Sensor / Transducer
from Sensor Developments, Inc.
This series of threaded rod load cells is designed for general tension measurement applications. Both English and Metric versions are available (models 10188 & 10190, respectively). All models are machined from high strength steel alloy. A durable, molded elastomer cover offers mechanical. [See More]
- Package: Rod End - Male
- Accuracy: 0.10
- Force Rating: 2000 to 44960
- Output: Analog Voltage
from tecsis LP
The rod-end design of this load cell is effective for bi-directional in-line force measurement. With ranges from 2,000 to 750,000 lbs and customer specified thread combinations, these units cover a variety of critical in-line force applications including wire line tension monitoring, overhead crane... [See More]
- Package: Rod End - Male
- Force Measured: Tension; Compression
- Force Rating: 2000 to 750000
- Output: Analog Voltage
from Montalvo Corporation
Not all load cells are created equal. As part of the ES Series of load cells, Dead Shaft/Idler load cells deliver the finest sensitivity in the industry. Accuracy, Precision, Consistency, & Functionality combine to make the most reliable & repeatable tension sensing system available today. [See More]
- Package: Rod End - Male
- Force Measured: Tension
- Force Rating: 25 to 500
- Output: Analog Current
from NOSHOK, Inc.
Available in a variety of sizes and shapres to fit almost any application. Measuring ranges from 0 kN to 5 kN through 0 kN to 5,000 kN. Accuracy levels range from ±2.0% Full Scale (B.F.S.L.) to ±0.04% Full Scale, depending on the version. Several outputs are available in both amplified and... [See More]
- Package: Bolt; Rod End - Male
- Accuracy: 0.20
- Force Rating: 0.0 to 112400
- Force Measured: Tension; Compression
from Stellar Technology
• Ranges from. 5K lbs. to 120K lbs. • In-Line Loading. • Small Diameter. • 0.20% Accuracy. • Welded Stainless Steel. • -40 °F to 250 °F Operation. • mV/V Output and. Amplified Output Available [See More]
- Package: Rod End - Male
- Accuracy: 0.20
- Force Rating: 5000 to 120000
- Force Measured: Tension
from Interface, Inc. - AZ
Why the Interface series REC Rod End Load Cell is the best in class: Proprietary Interface temperature compensated strain gages. Environmentally sealed. Stainless steel construction. Low deflection. More Information. The REC is a rod end load cell typically used with actuators where sensitivity to... [See More]
- Package: Rod End - Male
- Force Measured: Tension; Compression
- Force Rating: 1000 to 50000
- Output: Analog Voltage; 2 mV/V
from Montalvo Corporation
Not all load cells are created equal. As part of the ES Series of load cells, Dead Shaft/Idler load cells deliver the finest sensitivity in the industry. Accuracy, Precision, Consistency, & Functionality combine to make the most reliable & repeatable tension sensing system available today. [See More]
- Package: Rod End - Male
- Force Measured: Tension
- Force Rating: 25 to 500
- Output: Analog Current