Differential Channels Temperature Signal Conditioners
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B37 nonlinearized module isolates, filters, and amplifies a single channel of temperature input from a thermocouple input signal and provides an analog... [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: J
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B37 nonlinearized module isolates, filters, and amplifies a single channel of temperature input from a thermocouple input signal and provides an analog... [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: K
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B37 nonlinearized module isolates, filters, and amplifies a single channel of temperature input from a thermocouple input signal and provides an analog... [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: R
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B37 nonlinearized module isolates, filters, and amplifies a single channel of temperature input from a thermocouple input signal and provides an analog... [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: S
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B37 nonlinearized module isolates, filters, and amplifies a single channel of temperature input from a thermocouple input signal and provides an analog... [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: T
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: J
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: J
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: J
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: K
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: K
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: K
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: K
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: T
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
8B modules are an optimal solution for monitoring real-world process signals and providing high-level signals to a data acquisition system. Each 8B47 module isolates, filters, amplifies, and linearizes a single channel of temperature input from a thermocouple and provides an analog voltage output. [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: T
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Dataforth Corporation
Each DSCA34 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high-level voltage output. Signal filtering is accomplished with a five-pole filter which provides 85dB of normal-mode rejection at 60Hz and 80dB at 50Hz. An... [See More]
- Form Factor: DIN Rail
- Configuration: 2-Wire; 3-Wire
- Inputs: RTD Input
- Material: Platinum; Nickel
from Dataforth Corporation
Each DSCP20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input type, measurement range, and other features are software configurable. A PC, the DSCX-887 and DSCX-416 interface cables, and the DSCX-895 configuration software are required to configure the... [See More]
- Form Factor: DIN Rail
- Channels: 1
- Inputs: Thermocouple Input; RTD Input
- Differential Channels: Yes
from Dataforth Corporation
Each DSCT34 RTD input transmitter provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a process current output. Signal filtering is accomplished with a five-pole filter, which provides 85dB of normal-mode rejection at 60Hz and 80dB at 50Hz. An... [See More]
- Form Factor: DIN Rail
- Configuration: 2-Wire; 3-Wire
- Inputs: RTD Input
- Material: Platinum; Nickel
from Dataforth Corporation
Each SCM5B34 RTD input module provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a high-level analog voltage output. This voltage output is logic switch controlled, which allows these modules to share a common analog bus without the... [See More]
- Form Factor: Rack Mount; DIN Rail
- Configuration: 2-Wire (optional feature); 3-Wire (optional feature)
- Inputs: RTD Input
- Material: Platinum (optional feature); Copper (optional feature); Nickel (optional feature)
from Dataforth Corporation
Each SCM7B34/34N RTD input module accepts a single channel of 100 ohm Platinum (a = 0.00385) or 120 ohm Nickel (a = 0.00672) RTD input and produces an input voltage in response to a low-level current excitation. The input signal is filtered, isolated, amplified, linearized, and converted to a... [See More]
- Form Factor: Rack Mount; DIN Rail
- Configuration: 2-Wire; 3-Wire
- Inputs: RTD Input
- Material: Platinum; Nickel
from Dataforth Corporation
The SCM9B-1000/2000 Sensor-to-Computer Modules are a family of complete solutions designed for data acquisition systems based on personal computers and other processor-based equipment with standard serial I/O ports. The modules convert analog input signals to engineering units and transmit in ASCII... [See More]
- Form Factor: Panel / Chassis Mount
- T/C Type: E; J; K; T; B; S; R; C
- Inputs: Thermocouple Input
- Channels: 1
from Opto 22
Type T Thermocouple Input [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: T
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Acromag, Inc.
100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input. 4 to 20mA DC output. 12-50V DC from output loop power. DIP-switch configuration, push-button calibration. These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be... [See More]
- Form Factor: Rack Mount (optional feature); DIN Rail
- Configuration: 2-Wire (optional feature); 3-Wire (optional feature); 4-Wire (optional feature)
- Inputs: RTD Input
- Material: Platinum (optional feature); Copper (optional feature); Nickel (optional feature)
from Opto 22
Type E Thermocouple Input [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: E
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Acromag, Inc.
TC (types J, K T, R, S, E, B, N), ±1V DC, selectable range/type input. 4 to 20mA DC output. 12-50V DC from output loop power. DIP-switch configuration, signal linearizer, push-button calibration. These units accept universal thermocouple and millivolt input signals, provide isolation, and... [See More]
- Form Factor: Rack Mount (optional feature); DIN Rail
- DC Voltage: 0 to 125mVDC
- Inputs: Thermocouple Input
- T/C Type: E (optional feature); J (optional feature); K (optional feature); N (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)
from Opto 22
Type S Thermocouple Input [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: S
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Acromag, Inc.
2 or 4 input channels, RTD (100 ohm Pt, 120 ohm Ni, 10 ohm Cu) or resistance (0 to 500 ohms) input. Solid-state relays discrete output, Form A, SPST-NO. 10 to 36V DC, 24V AC power. Modbus-RTU high-speed RS-485. This signal conditioner is a dual or quad-channel analog input module with one... [See More]
- Form Factor: DIN Rail
- Configuration: 3-Wire
- Inputs: RTD Input
- Material: Platinum (optional feature); Copper (optional feature); Nickel (optional feature)
from Opto 22
ICTD Temperature Input [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: B
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Acromag, Inc.
4 input channels, thermocouple (types J, K, T, R, S, E, B, N) or millivolt ( ±100mV DC) input. 4 alarm channels, open drain MOSFETS (1A DC loads, 0 to 35V DC). 10 to 36V DC, 24V AC power. Modbus-RTU high-speed RS-485. This signal conditioner is a four-channel analog input module with four... [See More]
- Form Factor: DIN Rail
- DC Voltage: ±100 mVDC
- Inputs: Thermocouple Input
- T/C Type: E (optional feature); J (optional feature); K (optional feature); N (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)
from Opto 22
Type J Thermocouple Input [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: J
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Acromag, Inc.
i2o Option. 4 or 6 input channels, thermocouple or DC millivolts (user-selectable). 15 to 36V DC Power. EtherNet/IP ® or Ethernet Modbus TCP/IP 10/100Mbps network, i2o input-to-output capability. These modules provide an isolated Ethernet network interface for up to six input channels. [See More]
- Form Factor: DIN Rail
- DC Voltage: +/-100m, +/-1VDC
- Inputs: Thermocouple Input
- T/C Type: E; J; K; N; T; B; S; R
from Opto 22
Type K Thermocouple Input [See More]
- Form Factor: Modular Bay or Slot System
- T/C Type: K
- Inputs: Thermocouple Input
- CJC: Cold Junction Compensation
from Acromag, Inc.
i2o Option. 4 or 6 input channels, Platinum 100 ohm, Nickel 120 ohm, Copper 10 ohm; 0 to 500 ohms resistance. 15 to 36V DC power supply required. EtherNet/IP ® or Ethernet Modbus TCP/IP 10/100Mbps network, i2o input-to-output capability. These modules provide an isolated Ethernet network... [See More]
- Form Factor: DIN Rail
- Configuration: 2-Wire (optional feature); 3-Wire (optional feature)
- Inputs: RTD Input (optional feature); Resistance
- Material: Platinum (optional feature); Copper (optional feature); Nickel (optional feature)
from Acromag, Inc.
Thermocouple or Millivolt Signals. 4 or 6 input channels, thermocouple or DC millivolts (user-selectable). 12 to 36V DC power. Profibus-DP, RS-485 network up to 12Mbaud. These modules provide an isolated Profibus-DP network interface for up to six input channels. Differential inputs eliminate ground... [See More]
- Form Factor: DIN Rail
- DC Voltage: +/-100m, +/-1VDC
- Inputs: Thermocouple Input (optional feature)
- T/C Type: E; J; K; N; T; B; S; R
from Acromag, Inc.
Platinum RTD or copper RTD (resistance temperature sensor) input. DC voltage/current output. These models convert sensor inputs to proportional process current or voltage output signals. Excellent accuracy and stability ensure reliable measurements in harsh industrial environments. 3-way isolation. [See More]
- Form Factor: DIN Rail
- Configuration: 2-Wire (optional feature); 3-Wire (optional feature); 4-Wire (optional feature)
- Inputs: RTD Input
- Material: Platinum
from Acromag, Inc.
bull; DC voltage or DC current input. • DC voltage or DC current output. • Loop or DC or AC power. • Excellent accuracy and stability ensure reliable measurements in harsh industrial environments. Input isolated from output/power. These models convert sensor inputs to proportional... [See More]
- Form Factor: DIN Rail
- T/C Type: E (optional feature); J (optional feature); K (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)
- Inputs: Thermocouple Input
- Channels: 1
from Acromag, Inc.
2 input channels, RTD (Pt, Ni, Cu) input. Dual mechanical relay outputs. 10-36V DC power. Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability. IntelliPack alarms compare inputs against user defined limit setpoints... [See More]
- Form Factor: Terminal Block
- Configuration: 2-Wire (optional feature); 3-Wire (optional feature); 4-Wire (optional feature)
- Inputs: RTD Input
- Material: Platinum (optional feature); Copper (optional feature); Nickel (optional feature)
from Acromag, Inc.
2 input channels, thermocouple (types J, K, T, R, S, E, B, N), or millivolt ( ±100mV DC) input. Dual mechanical relays output. 10-36V DC power. Software configured; multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection); on/off controller capability. [See More]
- Form Factor: Terminal Block
- DC Voltage: ±1 or 500mVDC
- Inputs: Thermocouple Input
- T/C Type: E (optional feature); J (optional feature); K (optional feature); N (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)
from Acromag, Inc.
Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt ( ±100mV DC) input. Single or dual mechanical relay alarms. 10-36V DC power. Software configured. Multi-function alarms (limit, window, deviation, rate-of-change, peak/valley detection). On/off controller capability. Acromag's... [See More]
- Form Factor: DIN Rail; Terminal Block
- DC Voltage: ±1 or 500mVDC
- Inputs: Thermocouple Input; RTD Input
- T/C Type: E (optional feature); J (optional feature); K (optional feature); N (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)
from Acromag, Inc.
Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt ( ±100mV DC), 0 to 500 ohms input. 0 to 20mA DC, 0 to 10V DC output. Mechanical relay (25V @ 5A) alarm. 10-36V DC power. Software configured. Performs linearization, square root extraction, and optional limit alarm functions. [See More]
- Form Factor: DIN Rail; Terminal Block
- DC Voltage: ±1 or 500mVDC
- Inputs: Thermocouple Input; RTD Input
- T/C Type: E (optional feature); J (optional feature); K (optional feature); N (optional feature); T (optional feature); B (optional feature); S (optional feature); R (optional feature)