Specialty / Other Product and Material Test Fixtures and Accessories
from Haida International Equipment Co., Ltd.
Product description. Vertical Fluter is used to make sample for CMT for testing flat crush strength and vertical crush strength of corrugating medium. Designed standard. ISO 7263,QB/T 1061,TAPPI T809. Test Specimen. In standard atmospheric conditions processing to equilibrium state and then incised... [See More]
- Application: Flat / Vertical Crush
- Test Standard: ISO
from ZwickRoell LP
digiClip is available from ZwickRoell in four different versions for extension and/or change-in-width measurement. This digital system delivers uniform accuracy over the entire gauge length. digiClips' compact design is made possible by miniaturizing the digital scale. Furthermore, the lightweight... [See More]
- Application: Compression; Tensile; Change in width, Biaxial measurement
- Stroke / Maximum Opening: 1.57
- Test Fixture Type: Extensometer
- Operation: Manual
from Kin-Tek Laboratories Inc.
Used for generating moderate concentrations of low vapor pressure compounds such as C2H5SH, benzene, and water, and for generating high concentration mixtues of SO2, CH,3SH and other moderate vapor pressure compounds. Typical emission rate is 1 to 10 ppm, depending on the compound and the operating... [See More]
- Application: Calibration, Labatory
- Test Fixture Type: Standard / Test Block
from United Testing Systems, Inc.
Specifically designed to determine Poisson's ratio. Unit weighs only 40 grams. Meets ASTM E-83, Class B-1 and B-2 specifications. High temperature version (up to 350 °F) also available. [See More]
- Application: Gaging; Poisson's Ratio
- Test Standard: ASTM
- Test Fixture Type: Extensometer
- Operation: Electric
from Froude, Inc.
Froude can design, manufacture and supply of a range of ancillary equipment for engine dynamometer test cells for turnkey projects and specific applications. TEST STANDS | TROLLEYS. Cradles are designed to be used with all of the following engines: Gem, Gnome, RTM322, TPE331, PT6A, PT6T, PW100,... [See More]
- Application: Endurance testing, Performance testing, Quality assurance
- Test Fixture Type: Test Stand
from Haida International Equipment Co., Ltd.
Paper Water Proof Packaging Machine. 1. High accuracy. 2. Reasonable price with quality guarantee. 3. 1 year gurantee. Usage. The tester is used to test the waterproof ability of paper and paper cardboard. User can check the condition of the sample with the standard table, and then assess its... [See More]
- Application: Water Proof Testing
from ZwickRoell LP
The laserXtens 1-32 HP/TZ measures deformations on different materials in various environmental conditions, without making contact. The measuring principle eliminates the need to apply gauge marks. The laserXtens 1-32 HP/TZ is ideal for deformation measurement of small specimens starting at a gauge... [See More]
- Application: Compression; Flexure or Bending; Tensile; Change in width, Strain, Test Re-Run, 2D dot matrix
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 1.18
from Kin-Tek Laboratories Inc.
Generate moderate concentrations of low vapor pressure compounds such as acrylonitrile, benzene, styrene, etc. and high concentrations of SO2, CH3SH and other moderate vapor compounds. [See More]
- Application: Calibration, Labatory
- Test Fixture Type: Standard / Test Block
from United Testing Systems, Inc.
Using the principles of laser diffraction, this unique system is designed to accurately measure the cross section of carbon and other opaque fibers and filaments in the diameter range of five to fifty microns. The unit is available in both single and dual array configuration. The single array system... [See More]
- Application: Gaging; Non-Contact Extension
- Operation: Electric
- Test Fixture Type: Extensometer
from ZwickRoell LP
The laserXtens 2-120 HP/TZ measures deformations on different materials in various environmental conditions, without making contact. The measurement principle eliminates the need to apply gauge marks. The laserXtens 2-120 HP/TZ is ideal for the deformation measurement of specimens with gauge lengths... [See More]
- Application: Compression; Flexure or Bending; Tensile; Change in width, Strain, Test Re-Run, 2D dot matrix
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 2.36
from Kin-Tek Laboratories Inc.
Generate moderate concentrations of high vapor pressure compounds such as SO2, H2S, NH3, Cl2, etc. and very low concentrations of low vapor pressure compounds such as carbon disulfide, methylene chloride, nitric acid, etc. [See More]
- Application: Calibration, Labatory
- Test Fixture Type: Standard / Test Block
from ZwickRoell LP
The laserXtens 2-220 HP provides high-accuracy, non-contact measurement without the need for gauge marks for tensile, compression and flexure testing on metals. The system reliably performs closed-loop strain-rate controlled tests to ISO 6892-1 Method A1. The laserXtens is easy to operate and... [See More]
- Application: Compression; Fatigue; Flexure or Bending; Tensile; Change in width
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 1.97
from Kin-Tek Laboratories Inc.
Generates high concentration mixtures of high vapor pressure gases CO, CO2, NO, N2O, CH4, etc. Typical concentrations: 10 ppm to over 1,000 ppm. Tube dimensions: 1 ¾ inches diameter by 6 inches long [See More]
- Application: Calibration, Labatory
- Test Fixture Type: Standard / Test Block
from ZwickRoell LP
The laserXtens 7-220 HP provides high-accuracy, non-contact measurement without the need for gauge marks for tensile, compression and flexure testing on metals. Due to the patented laserXtens array technology it has a wide measurement range and full view of the entire specimen, which allows for the... [See More]
- Application: Compression; Fatigue; Flexure or Bending; Tensile; Change in width, Strain, Test Re-Run, 2D dot matrix
- Stroke / Maximum Opening: 8.27
- Test Fixture Type: Extensometer
- Operation: Laser
from Kin-Tek Laboratories Inc.
Generates low concentration gas standards of high vapor pressure gases such as CO, CO2, NO, CH4 etc. Typical concentrations: ppb to 10 ppm. Tube dimensions: 1 ¾ inches diameter by 6 inches long [See More]
- Application: Calibration, Labatory
- Test Fixture Type: Standard / Test Block
from ZwickRoell LP
Measurement of change in width over the entire gauge length according to the recommendation of ISO 10113:2020. [See More]
- Application: Tensile; Hysteresis
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 39.37
from Kin-Tek Laboratories Inc.
Generates extremely low concentration mixtures of Cl2, NO2, COCl2, SO2, H2S. Features long life for service in remote areas where the use of disposable permeation tubes is impractical. Tube dimensions: 1 inch diameter by 6 inches long. [See More]
- Application: Calibration, Labatory
- Test Fixture Type: Standard / Test Block
from ZwickRoell LP
Strain gauge clip-on extensometers are manual clip-on extensometers, that are clamped to the specimen. With various preset gauge-lengths they are suitable for use on metal and plastic specimens. [See More]
- Application: Compression; Tensile; Strain
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 0.3937 to 0.9843
from ZwickRoell LP
The videoXtens 1-120 is a non-contact, camera based extensometer for specimens with small to medium extensions, such as sheet metals, plastics or geotextiles. [See More]
- Application: Tensile
- Test Fixture Type: Extensometer
from ZwickRoell LP
The videoXtens 1-270 covers a wide measurement range and is therefore excellent for high-extension materials or specimens with high initial gauge length. [See More]
- Application: Compression; Fatigue; Flexure or Bending; Tensile; Change in width, Strain, Test Re-Run, 2D dot matrix
- Test Standard: ASTM; DIN; ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 5.51
from ZwickRoell LP
The videoXtens 1-32 HP/TZ measures deformations on different materials in various environmental conditions, without making contact. The measuring principle requires application of gauge marks. The videoXtens 1-32 HP/TZ is ideal for deformation measurement of small specimens starting at a gauge... [See More]
- Application: Compression; Fatigue; Flexure or Bending; Tensile; Strain, Test Re-Run, 2D dot matrix
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Operation: Optical
from ZwickRoell LP
The videoXtens 2-120 HP sets new standards in accuracy and reproducibility. If high precision is required for strain measurement on plastics and fiber-reinforced composites, the videoXtens 2-120 HP is the perfect non-contact solution. [See More]
- Application: Compression; Fatigue; Flexure or Bending; Tensile; Change in width
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 5.12
from ZwickRoell LP
The videoXtens 3-300 includes three high-resolution cameras. ZwickRoell's innovative array technology combines the fields of view, creating one large FOV with high resolution. Ideal for specimens with a long initial gauge length or high extension that require accurate measurement. For example,... [See More]
- Application: Compression; Fatigue; Flexure or Bending; Tensile; Change in width, Strain, Test Re-Run, 2D dot matrix
- Test Standard: DIN; ISO
- Test Fixture Type: Extensometer
- Stroke / Maximum Opening: 12.2
from ZwickRoell LP
An extensometer for everything: from determination of the tensile modulus and Poisson's ratio to specimen break, and for testing at ambient temperature as well as in a temperature chamber. The videoXtens biax 2-150 HP is an optical extensometer that was specifically developed for testing of... [See More]
- Application: Compression; Tensile; Strain
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Operation: Optical
from ZwickRoell LP
Here is what differentiates the videoXtens T-160 HP from the other optical transverse strain extensometers: [See More]
- Application: Compression; Tensile; Strain
- Test Standard: ISO
- Test Fixture Type: Extensometer
- Width / Diameter: 1.57
from ZwickRoell LP
A very important factor in obtaining reliable test results is to ensure minimum influence of the displacement transducer on the test. The ZwickRoell displacement transducer ensures reliable test results through secure attachment, precise axial alignment and tracking, and a small increase in contact... [See More]
- Application: Compression; Flexure or Bending; Components testing
- Test Standard: ASTM; ISO
- Test Fixture Type: Extensometer
- Operation: Manual