Switch / Alarm Relay Output Conductivity and Resistivity Meters
from ABB Measurement & Analytics
Overview. The AWT210 offers the power of advanced digital communications in a simple, flexible design, enabling you to get up and running quickly. 'Easy Setup' sensor configuration menus provide step-by-step guidance. Advanced self-diagnostics conforming to NAMUR NE 107 provide harmonized indication... [See More]
- Electrical Output: Switch / Alarm Relay
- Accuracy: 1
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- Form Factor: Panel
from Myron L Company
Myron L ® Company ’s new 900 Series Multi-Parameter Monitor / Controllers combine Accuracy, Reliability, Simplicity, and Flexibility. The user intuitive GUI (Graphical User Interface) allows easy and complete programmability of the instrument all from the LCD touch screen. These highly... [See More]
- Electrical Output: Analog Voltage; Analog Current; Switch / Alarm Relay
- Number of Control Relays: 3
- Water Quality Parameters: Measures Conductivity / Dissolved Solids; Measures Resistivity
- Form Factor: Lab / Benchtop
from ABB Measurement & Analytics
AV412 UV254 dual-channel, low- and high-range dissolved organics monitors are designed for use on potable water treatment plants. In particular, they can be used to monitor the quality of the outlet from sand and carbon filters to provide a THM precursor measurement. Long term field trials have... [See More]
- Electrical Output: Analog Current; Switch / Alarm Relay
- Form Factor: Panel; Wall, Pipe
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- Display Type: Digital
from ABB Measurement & Analytics
The Aztec 600 high range manganese analyzer provides a wide operating range of up to 10 ppm Mn (10 mg/l), making it ideal for monitoring manganese levels in source waters. Featuring ABB's intuitive menu-driven software and the unique self-cleaning Aztec fluid handling system, users benefit from an... [See More]
- Electrical Output: Switch / Alarm Relay
- Accuracy: 5 to 7
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- Form Factor: Lab / Benchtop
from Fischer Technology, Inc.
SIGMASCOPE SMP350 is a compact handheld device for determining the electrical conductivity of non-ferrous metals such as aluminum or copper. The measured conductivity further enables you to draw conclusions about the hardness and strength of heat-treated materials. Evidence of heat damage and... [See More]
- Electrical Output: Switch / Alarm Relay
- Conductivity Range: 5.00E9 to 6.50E11
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- Accuracy: 0.5000
from HORIBA Instruments, Inc.
The CS-153 is a high-precision chemical solution concentration monitor designed to meet the strict demands of semiconductor wet-etching processes. Etching processes use FPM solution to etch silicon oxide and remove particles from the wafer surface. The CS-153 continually monitors each component of... [See More]
- Electrical Output: Analog Current; Switch / Alarm Relay
- Process Temp: 68 to 176
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- Form Factor: In-situ / Field
from OMEGA Engineering, Inc.
The CDCN442 toroidal conductivity system isdesigned for online monitoring of chemically aggressive process solutions, water applications that coat or foul traditional sensors, and plating bath operations in which high current densities are present. The sensor consists of 2 metallic ribbon coils that... [See More]
- Electrical Output: Analog Current; Switch / Alarm Relay
- Conductivity Range: 10000 to 1.00E6
- Water Quality Parameters: Measures Conductivity / Dissolved Solids; Measures Resistivity
- Resistivity Range: 10000 to ?
from optek-Danulat, Inc.
The CONTROL 200 electrochemical converter is designed for continuous monitoring and control of pH and conductivity. The C200 series is available either as a single input (pH or conductivity) or dual input (pH and/or conductivity) converter. Operation and programming is simple, using pushbuttons on... [See More]
- Electrical Output: Analog Current; Switch / Alarm Relay
- Conductivity Range: 1 to 850000
- Water Quality Parameters: Measures Conductivity / Dissolved Solids (optional feature)
- Number of Control Relays: 3
from Iwaki America and Walchem, IWAKI America Inc
The WEC/WDEC410 Series Single and Dual Input Electrodeless Conductivity Controllers measure conductivity of a solution via an encapsulated, non-contacting sensor to control replenishment pumps and alarms. They may be installed in a variety of very harsh chemical control applications, including oily... [See More]
- Electrical Output: Analog Current; Switch / Alarm Relay
- Conductivity Range: 50 to 1000
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- Accuracy: 1 to 3
from HORIBA Instruments, Inc.
The HE-480R industrial resistivity meter features the high-precision temperature compensation function. Its high-performance temperature compensation makes it ideal for sequential monitoring of ultra-pure water used in manufacturing processes in the semiconductor field, and many other fields,... [See More]
- Electrical Output: Analog Current; Switch / Alarm Relay
- Resistivity Range: 0.0 to 100000
- Water Quality Parameters: Measures Resistivity
- Process Temp: 32 to 212
from OMEGA Engineering, Inc.
The CDCN-91 series dual channel conductivity/resistivity controller is a two-channel input device equipped with three scalable 4 to 20 mA outputs and four programmable relays. A selector switch activates two open collector outputs in place of two of the relays for extraordinary output versatility. [See More]
- Electrical Output: Analog Current; Switch / Alarm Relay
- Conductivity Range: 0.0550 to 400000
- Water Quality Parameters: Measures Conductivity / Dissolved Solids; Measures Resistivity
- Accuracy: 2
from OMEGA Engineering, Inc.
The CDH-720 and TDS-720 Series water-resistant conductivity/TDS meters are OMEGA ’s reply to requests of accurate, low maintenance process monitoring equipment at affordable costs. Four different models are available to cover all applications. Each meter is supplied with a direct 2 pin probe... [See More]
- Electrical Output: Switch / Alarm Relay
- Conductivity Range: 0.0 to 9990
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- Accuracy: 2