Encapsulated Transformers Transformers
from DigiKey
Isolation and Data Interface (Encapsulated) Pulse Transformer Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 85
from RS Components, Ltd.
Line Matching Transformer 600uH 1:1 [See More]
- Category: Signal
- Mounting: Chip Transformer; Surface Mount
- Other Transformer Types / Applications: Audio
- Standards: RoHS
from DigiKey
TRANSF HIGH VOLTAGE ISOLATION [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from RS Components, Ltd.
Minature 12Vdc 1A Power Supply [See More]
- Mounting: Encapsulated
- Standards: RoHS
from DigiKey
TRANSF HIGH VOLTAGE ISOLATION [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from RS Components, Ltd.
1.5A Encapsulated Variable Transformer [See More]
- Other Transformer Types / Applications: Single Phase Transformer; Variac
- Mounting: Chip Transformer; Surface Mount
- Winding Turns: Variable
- Input Voltage: 240
from DigiKey
XFMR 3.3-5V/3.3-15V,350MA PK TR [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from RS Components, Ltd.
1Ph 1A Encapsulated Variable Transformer [See More]
- Other Transformer Types / Applications: Single Phase Transformer; Variac
- Mounting: Chip Transformer; Surface Mount
- Winding Turns: Variable
- Input Voltage: 240
from DigiKey
XFMR 3.3-5V/3.3-15V,350MA PK TR [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from RS Components, Ltd.
1Ph 4A Encapsulated Variable Transformer [See More]
- Other Transformer Types / Applications: Single Phase Transformer; Variac
- Mounting: Chip Transformer; Surface Mount
- Winding Turns: Variable
- Input Voltage: 240
from DigiKey
XFMR 3.3-5V/3.3-15V,350MA PK TR [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from RS Components, Ltd.
1Ph 8A Encapsulated Variable Transformer [See More]
- Other Transformer Types / Applications: Single Phase Transformer; Variac
- Mounting: Chip Transformer; Surface Mount
- Winding Turns: Variable
- Input Voltage: 240
from DigiKey
300 µH Isolation and Data Interface (Encapsulated) Pulse Transformer 3:5 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from RS Components, Ltd.
1Ph 6A Encapsulated Variable Transformer [See More]
- Other Transformer Types / Applications: Single Phase Transformer; Variac
- Mounting: Chip Transformer; Surface Mount
- Winding Turns: Variable
- Input Voltage: 240
from DigiKey
300 µH Isolation and Data Interface (Encapsulated) Pulse Transformer 3:8 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from DigiKey
250 µH Isolation and Data Interface (Encapsulated) Pulse Transformer 4:3 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from DigiKey
250 µH Isolation and Data Interface (Encapsulated) Pulse Transformer 8:9 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 125
from DigiKey
200 µH Isolation and Data Interface (Encapsulated) Pulse Transformer 1CT:1.414CT Transmitter, 1CT:1CT Receiver Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: 0 to 70
from DigiKey
100 µH Isolation and Data Interface (Encapsulated) Pulse Transformer 1:1 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: 0 to 70
from DigiKey
100 µH Isolation and Data Interface (Encapsulated) Pulse Transformer 1:1 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: 0 to 70
from DigiKey
2.5mH SCR and Triac Trigger (Encapsulated) Pulse Transformer 1:1 Through Hole [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -25 to 70
from DigiKey
2.5mH SCR and Triac Trigger (Encapsulated) Pulse Transformer 1:1:1 Through Hole [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -25 to 70
from DigiKey
1.2mH Isolation and Data Interface (Encapsulated) Pulse Transformer 1:1:1 Through Hole [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -25 to 100
from DigiKey
1.2mH SCR and Triac Trigger (Encapsulated) Pulse Transformer 1:1:1 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -25 to 100
from DigiKey
ISNA PULSE TRANSFORMER SMD 0.1A [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -25 to 100
from DigiKey
ISNA PULSE TRANSFORMER SMD 0.17A [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -25 to 100
from DigiKey
1.1mH SCR and Triac Trigger (Encapsulated) Pulse Transformer 1:1:1 Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -25 to 100
from DigiKey
Isolation and Data Interface (Encapsulated) Pulse Transformer 1CT:1CT Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: 0 to 70
from DigiKey
Isolation and Data Interface (Encapsulated) Pulse Transformer 1CT:1CT Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: 0 to 70
from DigiKey
Isolation and Data Interface (Encapsulated) Pulse Transformer 1:1 Transmitter, 1:1 Receiver Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: -40 to 85
from DigiKey
Isolation and Data Interface (Encapsulated) Pulse Transformer 1CT:1CT Through Hole [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
from DigiKey
Isolation and Data Interface (Encapsulated) Pulse Transformer 1CT:1CT Surface Mount [See More]
- Category: Signal
- Mounting: Chip Transformer
- Other Transformer Types / Applications: Pulse Transformers
- Operating Temperature: 0 to 70
from Block USA, Inc.
Rated input voltage 115/220/230/240 Vac. Rated output voltage 115/220/230/240 Vac. Rated output voltage 0.8 - 16 A. Insulation class A or B. Maximum ambient temperature 40 °C. Degree of protection IP 20. Autotransformer. to: VDE 0570 Part 2-13, DIN EN 61558-2-13, EN 61558-2-13,. IEC 61558-2-13. [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Autotransformer
- Input Voltage: 115 to 240
from Dongguan Yili Electronics Co., Ltd.
A buck –boost transformer is a type of transformer used to make adjustments to the voltage applied to alternating current equipment.[1] Buck –boost connections are used in several places such as uninterruptible power supply (UPS) units for computers and in the tanning bed industry. Buck... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Winding Turns: Step-Down Transformer
- Power Rating (VA): 50 to 5000
from Hubbell Incorporated
4.5 INCH W X 4.13 INCH D X 3.84 INCH H SIZE. 50/60 HZ FREQUENCY RATING. UL, CUL APPROVAL. 0.4 INCH L X 0.2 INCH W SLOT MOUNTING. 250 VA POWER RATING. 120 X 240 V PRIMARY VOLTAGE. 24 V SECONDARY VOLTAGE. 105 INSULATION CLASS. 55 DEG C TEMPERATURE RISE. NUMBER OF PHASES 1. AE MODEL [See More]
- Other Transformer Types / Applications: Industrial Control Transformer
- Input Voltage: 120 to 240
- Operating Frequency: 50 to 60
- Output Voltage: 24
from Avel Lindberg, Inc.
Horizontal Fixing Option. Vertical Fixing Option. Toroidal Construction. Thermally Protected Primary. Fully Encapsulated to UL 94VO. Dual Secondaries. Low Magnetic Field. Low Surface Temperature. Low Induced Noise (Audible). Double Insulated Flexible PVC leads. Available PCB or Flying Lead, Primary... [See More]
- Category: Power
- Winding Turns: Step-Down Transformer
- Other Transformer Types / Applications: Power Transformer
- Mounting: PCB/SMD
from Premier Magnetics, Inc.
115V Single -OR- 230V Primaries, 50Hz to 60Hz. Low Capacitive Coupling Minimizes Line Noise. 2.8VA. 1500Vrms Isolation (Hipot) [See More]
- Category: Power
- Winding Turns: Step-Down Transformer
- Other Transformer Types / Applications: Power Transformer
- Mounting: PCB/SMD
from Schneider Electric
From medium voltage switchgear and arc resistant equipment to energy automation, we deliver specific solutions for data centers, commercial and industrial buildings, water/wastewater, healthcare, utilities, oil and gas, and mining, covering all power distribution needs for energy management. [See More]
- Category: Power
- Other Transformer Types / Applications: Harmonic Mitigating Transformer; Industrial Control Transformer; Isolation; Buck-Boost Transformers; Power Transformer; Single Phase Transformer; Substation Transformer; Three Phase Transformers
- Cooling Method: Air; Oil
- Mounting: Chassis; Pad-Mounted
from Hengda Electronic Factory
It adopts high-brand silicon steel sheet to produce ring core, with low dissipation and high efficiency. Special winding process ensures high reliability of transformer. The finishing of the shell is made, the dimensions are arbitrary adjustment. Epoxy resin vacuum irrigation, moisture-proof,... [See More]
- Category: Signal
- Other Transformer Types / Applications: Electronics
- Cooling Method: Air
- Winding Turns: Variable
from Acme Electric Corp. / Power Distribution Products
The Acme Electric AE and CE Series Industrial Control Transformers are designed specifically for machine tool control circuit applications. These transformers have the ability to handle potentially damaging high in-rush currents that occur when electromagnetic components are energized, without... [See More]
- Category: Power
- Other Transformer Types / Applications: Industrial Control Transformer; Power Transformer
- Cooling Method: Air
- Winding Turns: Step-Down Transformer
from Pentair, Inc.
- Other Transformer Types / Applications: Industrial Control Transformer
from Block USA, Inc.
Rated input voltage 3 x 200/208 - 3 x 690 Vac. Rated output voltage 3 x 400 Vac. Rated power 2000 - 250000 VA. Insulation class F. Maximum ambient temperature 40 °C. Efficiency up to 98 %. Degree of protection IP 00/23/54. Optionally adapted package for higher degrees of protection. [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Autotransformer
- Input Voltage: 200 to 208
from Dongguan Yili Electronics Co., Ltd.
Landscape Transformers supply low-voltage 12/13/14/15V power to low-voltage landscape lighting, outdoor lighting, garden lighting, swimming pool, and spa lights as well as submersible lighting fixtures in residential and commercial applications. [See More]
- Category: Power
- Output Voltage: 12 to ?
- Input Voltage: ? to 120
- Operating Temperature: 20 to 70
from Hubbell Incorporated
5.25 INCH W X 6.31 INCH D X 4.97 INCH H SIZE. 50/60 HZ FREQUENCY RATING. UL, CUL APPROVAL. 0.69 INCH L X 0.31 INCH W SLOT MOUNTING. 500 VA POWER RATING. 200/220/440 V, 208/230/460 V, 240/480 V PRIMARY VOLTAGE. 23/110 V, 24/115 V, 25/120 V SECONDARY VOLTAGE. 105 INSULATION CLASS. 55 DEG C TEMPERATURE... [See More]
- Other Transformer Types / Applications: Industrial Control Transformer
- Input Voltage: 200 to 480
- Operating Frequency: 50 to 60
- Output Voltage: 23 to 120
from Acme Electric Corp. / Power Distribution Products
Acme ’s low voltage distribution transformers are designed for industrial and commercial applications. All of Acme ’s general purpose transformers are rated for 600 volts and below. Encapsulated units are offered in ratings up to 15kVA. Ventilated units are available in ratings up to... [See More]
- Category: Power
- Other Transformer Types / Applications: Power Transformer; Three Phase Transformers
- Cooling Method: Air
- Winding Turns: Step-Down Transformer
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 110 Vac. Rated power 250 - 1000 VA. Insulation class A. Maximum ambient temperature 40 °C. Efficiency up to 96 %. Degree of protection IP 22. Autotransformer. to: VDE 0570 Part 2-13, DIN EN 61558-2-13, EN 61558-2-13,. IEC 61558-2-13. [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Autotransformer
- Input Voltage: 230
from Dongguan Yili Electronics Co., Ltd.
Landscape Transformers supply low-voltage 12/13/14/15V power to low-voltage landscape lighting, outdoor lighting, garden lighting, swimming pool, lawn lighting and spa lights as well as submersible lighting fixtures in residential and commercial applications. [See More]
- Other Transformer Types / Applications: Lighting Transformer
- Input Voltage: 120
- Mounting: wall or stanchion mount, using the mounting tab at the top
- Operating Temperature: -20 to 70
from Hubbell Incorporated
5.25 INCH W X 6.81 INCH D X 4.97 INCH H SIZE. 50/60 HZ FREQUENCY RATING. UL, CUL APPROVAL. 0.69 INCH L X 0.31 INCH W SLOT MOUNTING. 750 VA POWER RATING. 200/220/440 V, 208/230/460 V, 240/480 V PRIMARY VOLTAGE. 23/110 V, 24/115 V, 25/120 V SECONDARY VOLTAGE. 105 INSULATION CLASS. 55 DEG C TEMPERATURE... [See More]
- Other Transformer Types / Applications: Industrial Control Transformer
- Input Voltage: 200 to 480
- Operating Frequency: 50 to 60
- Output Voltage: 23 to 120
from Block USA, Inc.
Rated input voltage 110 Vac. Rated output voltage 230 Vac. Rated power 250 - 1000 VA. Insulation class A. Maximum ambient temperature 40 °C. Efficiency up to 96 %. Degree of protection IP 22. Autotransformer. to: VDE 0570 Part 2-13, DIN EN 61558-2-13, EN 61558-2-13,. IEC 61558-2-13. [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Autotransformer
- Input Voltage: 110
from Dongguan Yili Electronics Co., Ltd.
Magnetic power supply provides low voltage power to dimmable LED lights, pool lights and lighting fixtures in residential and commercial applications. They are compatible with on/off switches and MLV dimmers. All dimmers have been tested with our LED drivers in the laboratory. [See More]
- Cooling Method: Air
- Input Voltage: 120
- Mounting: vertically mounted using two keyholes at the top.
- Operating Temperature: -20 to 70
from Hubbell Incorporated
10.31 INCH W X 7.13 INCH D X 14.77 INCH H SIZE. 50/60 HZ FREQUENCY RATING. UL, CSA APPROVAL. ANSI, NEMA APPLICABLE STANDARD. PANEL MOUNTING. 2000 VA POWER RATING. 240/480/600 V PRIMARY VOLTAGE. 100/120 V SECONDARY VOLTAGE. 2000 POWER RATING IN VA. 55 DEG C TEMPERATURE RISE. TRANSFORMER[T], ACME. [See More]
- Other Transformer Types / Applications: Industrial Control Transformer
- Operating Frequency: 50 to 60
- Mounting: Panel Mounted
- Input Voltage: 240 to 600
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 12 Vac. Rated power 1.5 - 10 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 77 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Category: Power
- Mounting: PCB/SMD
- Other Transformer Types / Applications: Isolation
- Operating Frequency: 50 to 60
from Hubbell Incorporated
10.31 INCH W X 7.13 INCH D X 13.1 INCH H SIZE. 50/60 HZ FREQUENCY RATING. UL, CSA APPROVAL. NEMA APPLICABLE STANDARD. 1000 VA POWER RATING. 240 X 480 V PRIMARY VOLTAGE. 120 V SECONDARY VOLTAGE. 155 INSULATION CLASS. 55 DEG C TEMPERATURE RISE. NUMBER OF PHASES 1. T1812 MODEL [See More]
- Other Transformer Types / Applications: Industrial Control Transformer
- Input Voltage: 240 to 480
- Operating Frequency: 50 to 60
- Output Voltage: 120
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 230 Vac. Rated power 150 VA. Insulation class A. Maximum ambient temperature 40 °C. Efficiency up to 90 %. Degree of protection IP 40. Isolating transformer. to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4. Isolating... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 230 Vac. Rated power 160 - 2500 VA. Insulation class A. Maximum ambient temperature 40 °C. Degree of protection IP 67. Isolating transformer. to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4. Isolating transformer for the safe... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 115 Vac. Rated power 60 - 1000 VA. Insulation class A or B. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 20. Isolating transformer. to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4. [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 230 Vac. Rated power 2500 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 98 %. Degree of protection IP 65. Isolating transformer. to: VDE 0570 Part 2-4, DIN EN 61558-2-4, EN 61558-2-4, IEC 61558-2-4. Isolating... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 5 - 2 x 24 Vac. Rated power 2 - 52 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 81 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 115
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage I 9 Vac. Rated output voltage II 14.0-0-14.0 Vac. Rated power 4.34 - 37.3 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 78 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 115
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 6 - 2 x 21 Vac. Rated power 3 - 60 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 85 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 115
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 230 Vac. Rated power 250 VA. Ambient temperature +40 °C. Degree of protection IP 40. Magnetic voltage stabilizer acting as mains transformer in accordance with. VDE 0570 part 2-12, EN 61558-2-12; IEC 61558-2-12. Magnetic voltage stabilizer... [See More]
- Category: Power
- Input Voltage: 230
- Operating Frequency: 50
- Output Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 3.2 - 16 VA. Insulation class B. Maximum ambient temperature 40 - 60 °C. Efficiency up to 76 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Category: Power
- Mounting: PCB/SMD
- Other Transformer Types / Applications: Isolation
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 24 Vac. Rated power 5 - 50 VA. Insulation class B. Maximum ambient temperature 40 - 50 °C. Efficiency up to 87 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1, UL... [See More]
- Category: Power
- Mounting: PCB/SMD
- Other Transformer Types / Applications: Isolation
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 6 - 2 x 18 Vac. Rated power 4.5 - 50 VA. Insulation class B. Maximum ambient temperature 70 °C. Efficiency up to 84 %. Degree of protection IP 00. Mains transformer. to: VDE 0570 Teil 2-1, DIN EN 61558-2-1, EN 61558-2-1, IEC 61558-2-1. Safety... [See More]
- Category: Power
- Mounting: PCB/SMD
- Other Transformer Types / Applications: Isolation
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 8 - 2 x 18 Vac. Rated power 4.5 - 30 VA. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 84 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Category: Power
- Mounting: PCB/SMD
- Other Transformer Types / Applications: Isolation
- Operating Frequency: 50 to 60
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 24 Vac. Rated power 10 - 100 VA. Insulation class B. Maximum ambient temperature 25 °C. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6. Safety isolating transformer... [See More]
- Category: Power
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 24
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 24 Vac. Rated power 100 - 200 VA. Insulation class E. Maximum ambient temperature 40 °C. Degree of protection IP 44. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6. Safety isolating transformer... [See More]
- Category: Power
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 24
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 24 Vac. Rated power 25 - 630 VA. Insulation class E. Maximum ambient temperature 40 °C. Degree of protection IP 65 or IP 68. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6. Safety isolating... [See More]
- Category: Power
- Input Voltage: 230
- Operating Frequency: 50 to 60
- Output Voltage: 24
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 11.3 - 11.5 Vac. Rated output 60 - 300 W. Insulation class A. Maximum ambient temperature 40 °C. Efficiency up to 92 %. Degree of protection IP 20. Safety isolating transformer for halogen lamps. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation; Lighting Transformer
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 11.5 Vac. Rated power 50 W. Insulation class B. Maximum ambient temperature 40 °C. Efficiency up to 80 %. Degree of protection IP 20. Safety isolating transformer for halogen lamps. to: VDE 0570 Teil 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Lighting Transformer
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 12 Vac. Rated power 60 - 800 VA. Insulation class A. Maximum ambient temperature 40 °C. Efficiency up to 95 %. Degree of protection IP 20. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC 61558-2-6. [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 230
from Block USA, Inc.
Rated input voltage 2 x 115 Vac. Rated output voltage 2 x 6 - 2 x 18 Vac. Rated power 4 - 48 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 79 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 115
from Block USA, Inc.
Rated input voltage 230 Vac. Rated output voltage 2 x 6 - 2 x 18 Vac. Rated power 4 - 35 VA. Insulation class E. Maximum ambient temperature 40 °C. Efficiency up to 78 %. Degree of protection IP 00. Safety isolating transformer. to: VDE 0570 Part 2-6, DIN EN 61558-2-6, EN 61558-2-6, IEC... [See More]
- Category: Power
- Operating Frequency: 50 to 60
- Other Transformer Types / Applications: Isolation
- Input Voltage: 230