RS232/422/485 Data Loggers and Data Recorders

Last Updated: November 6, 2024 Reviewed by: Jon Lowy, consulting engineer

Description

RS232/422/485 data loggers and data recorders are specialized electronic devices designed to collect, store, and sometimes transmit data from various sensors and instruments. These devices are particularly useful in industrial and engineering applications where monitoring and recording of physical parameters such as temperature, pressure, and voltage are required. They can interface with a host computer for data visualization and analysis, and they often support multiple communication protocols, including RS232, RS422, and RS485, which are standard serial communication protocols used in industrial environments.

Working Principle

The working principle of RS232/422/485 data loggers and data recorders involves capturing physical parameters through connected sensors, converting these analog signals into digital format, and then storing or transmitting the data for further analysis. These devices typically feature universal input channels that can accept a wide range of signal types, including temperature, voltage, current, and more. The data is often stored in internal memory and can be retrieved via various communication interfaces such as RS232, Ethernet, or USB. Some models also include built-in software for configuration and real-time data visualization.

Applications

RS232/422/485 data loggers and data recorders are widely used in various industrial and engineering applications. They are ideal for process monitoring, temperature profiling, fault identification, and process documentation. These devices are also used in research and development (R&D) settings to collect and analyze data from multiple sensors. Specific applications include monitoring air compressors, diesel engine emissions, and other industrial equipment where precise data logging is crucial for performance optimization and regulatory compliance.

Advantages over other Data Loggers and Data Recorders

One of the primary advantages of RS232/422/485 data loggers and data recorders over other types is their ability to support multiple communication protocols, making them highly versatile for different industrial applications. They offer robust and reliable performance, often featuring large memory capacities to store extensive data points for extended logging sessions. Additionally, these devices can interface with various sensors and instruments, providing a comprehensive solution for data acquisition needs. The inclusion of advanced software for configuration and real-time data visualization further enhances their usability and functionality.

Limitations

Despite their numerous advantages, RS232/422/485 data loggers and data recorders have some limitations. One significant limitation is the potential complexity involved in configuring and setting up these devices, especially when dealing with multiple communication protocols and sensor types. Additionally, while they offer extensive data storage capabilities, retrieving and analyzing large volumes of data can be time-consuming and may require specialized software. Another limitation is that newer computers may not include serial ports, necessitating the use of USB or Ethernet interfaces, which can complicate the setup process.

Considerations

When selecting an RS232/422/485 data logger or data recorder, several considerations should be taken into account. These include the specific parameters to be measured, the required sample rate, and the environmental conditions in which the device will operate. It is also essential to consider the communication interfaces available on the device and their compatibility with existing systems. Additionally, the ease of configuration and data retrieval, as well as the availability of technical support and software updates, are important factors to ensure the device meets the specific needs of the application.

81 Results
Data Loggers -- 100029 [SD200 from Teledyne FLIR Systems, Inc.]
from RS Components, Ltd.

3 Channel Temperature Datalogger [See More]

  • Host Connection: RS232/422/485; USB; RS232, USB
  • Inputs: Thermocouple Input; Type K
  • Analog Channels: 3
  • Agency Approval: RoHS Compliant
Multi-channel Digital Transmitter -- AWT440
from ABB Measurement & Analytics

Users of the AWT440 benefit from plug-and-play connectivity, automatic sensor recognition and set-up. Enabling: – Automatic connection of up to 4 digital sensor. – Intuitive software with full colour graphical display. – Data logging and graphical process trending. – Full... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Digital I/O Channels: 6
  • Analog Channels: 4
  • Form Factor: Panel / Chassis Mount
Air Velocity / Temperature Data Logger -- PCE-007
from PCE Instruments / PCE Americas Inc.

Accurate Data- Logger meter with connection port, memory,. software for measuring wind speed, temperature and Data- Logger. This Data- Logger meter is very economical. With this Data- Logger meter you can measure wind speed and air temperature. Once you have the right cross section, the Data- Logger... [See More]

  • Host Connection: RS232/422/485
  • Application: General Lab & Industrial
  • Form Factor: Stand-alone
  • User Interface: Front Panel
Videographic Data Recorders -- PPS-1000
from Tempco Electric Heater Corporation

Product Overview. The PPS Series is a major advance in the market for Paperless Videographic Data Recorders incorporating Touch Screen Technology for set-up and programing. The PPS Series encompasses three models: • The PPS-1000 for basic 3 or 6 channel recording on a 4.3" screen. • The... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • Form Factor: Panel / Chassis Mount; Stand-alone
  • Analog Channels: 6
  • Inputs: Thermocouple Input; RTD Input
Data Loggers -- 1232231
from RS Components, Ltd.

Humidity & Temperature Data Logger [See More]

  • Host Connection: RS232/422/485; RS232
  • Inputs: Capacitive, Semiconductor
  • Analog Channels: 1
  • Outputs: Capacitance
Air Velocity / Temperature Data Logger -- PCE-009
from PCE Instruments / PCE Americas Inc.

Accurate data logger to measure air temperature and velocity with calculation. of volume of air current and RS-232 interface for data transfer. to a computer, software and cable is included This data logger has a good relation between price and quality and it combines accuracy and versatility with... [See More]

  • Host Connection: RS232/422/485
  • Application: General Lab & Industrial
  • Form Factor: Stand-alone
  • User Interface: Front Panel
Videographic Data Recorders -- PPS-2000
from Tempco Electric Heater Corporation

Product Overview. The PPS Series is a major advance in the market for Paperless Videographic Data Recorders incorporating Touch Screen Technology for set-up and programing. The PPS Series encompasses three models: • The PPS-1000 for basic 3 or 6 channel recording on a 4.3" screen. • The... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • Form Factor: Panel / Chassis Mount; Stand-alone
  • Analog Channels: 24
  • Inputs: Thermocouple Input; RTD Input
Data Loggers -- 1232234
from RS Components, Ltd.

Humidity & Temperature Data Logger [See More]

  • Host Connection: RS232/422/485; USB; RS232, USB
  • Inputs: Probe
  • Analog Channels: 2
  • Agency Approval: RoHS Compliant
Three Phase Power Data Logger -- PCE-PA 8000
from PCE Instruments / PCE Americas Inc.

The PCE-PA 8000 Three Phase Power Data Logger is able to measure and record the power in both single-phase or three-phase circuits. With the PCE-PA 8000 Three Phase Power Data Logger you will be able to perform prolonged measurements. Measurement values are saved in xls format on the included SD... [See More]

  • Host Connection: RS232/422/485
  • Application: General Lab & Industrial
  • Form Factor: Stand-alone
  • AC Voltage: 10 V ... 600 V (phase to neutral)
Videographic Data Recorders -- PPS-3000
from Tempco Electric Heater Corporation

Product Overview. The PPS Series is a major advance in the market for Paperless Videographic Data Recorders incorporating Touch Screen Technology for set-up and programing. The PPS Series encompasses three models: • The PPS-1000 for basic 3 or 6 channel recording on a 4.3" screen. • The... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • Form Factor: Panel / Chassis Mount; Stand-alone
  • Analog Channels: 48
  • Inputs: Thermocouple Input; RTD Input
Data Loggers -- 1232284
from RS Components, Ltd.

RSCAL(1232234) Hum & Temp Data Logger [See More]

  • Host Connection: RS232/422/485; USB; RS232, USB
  • Inputs: Probe
  • Analog Channels: 2
  • Agency Approval: RoHS Compliant
Data Loggers -- 1232381
from RS Components, Ltd.

RSCAL(1232231) Hum & Temp Data Logger [See More]

  • Host Connection: RS232/422/485; RS232
  • Inputs: Capacitive, Semiconductor
  • Analog Channels: 1
  • Outputs: Capacitance
Data Logger -- Gamma 30
from Sifam Tinsley UK

Gamma 30 Data logging, data processing, data analysis, data recording, Y(t) recorder XY recorder. Features. • Storing Data in Offline /online mode. • Transmission of data to PC in Online mode via RS 232 serial interface. • Optically isolated transmission from multi meter to adapter. [See More]

  • Host Connection: RS232/422/485
  • Form Factor: DIN Rail
  • Analog Channels: 1
  • Inputs: RS-232 Serial Interface
Communication Gateways - Datalogger -- DATALOG H60
from SOCOMEC

DATALOG H40 and H60 dataloggers associated with Socomec wireless interfaces enable you to create a smart energy data communication network in order to : • Remotely and automatically read multi-fluid energy meters and multi-function meters, isolated or not. • Centralise, secure and make... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • User Interface: None
  • Form Factor: Stand-alone
  • Network Options: Ethernet
Data Acquisition System -- Q.monixx A117
from Gantner Instruments, Inc.

Q.monixx is a new addition to the Q.series product family – the ideal edge computing and data logging solution for reliable process control and asset monitoring. The standard I/O configuration for the Q.monixx includes up to 8 universal analog inputs, 8 digital inputs, 4 digital outputs, 2... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Digital I/O Channels: 14
  • Analog Channels: 8
  • Resolution: 24
Data Acquisition & Communication Module -- M853
from Fluidwell bv

M853 is an ultra-low power “all-in-one ” Data Acquisition & Communication Module including datalogging, designed for a wide-range industrial applications. The M853 can be fully configured according to your process requirements. No additional signal converters / amplifiers,... [See More]

  • Host Connection: RS232/422/485
  • Digital I/O Channels: 4
  • Analog Channels: 4
  • Sampling Frequency: 0.0040
Cutting Edge Fixed Automatic Meter Reading System -- SpireCapture™
from Spire Metering Technology

Spire Metering offers specialized software solutions designed to deliver critical data necessary for analytic review. Having transparent and secure data readily available moves toward improved operational efficiency and resource management. The SpireCaptureTM system is a cutting edge fixed automatic... [See More]

  • Host Connection: RS232/422/485; Ethernet; Radio; Modbus, BACnet
  • Application: General Lab & Industrial
  • Form Factor: Stand-alone
  • Network Options: Ethernet; ModBus, GSM/GPRS
Field Data Scanning Unit -- SE3000 Series
from CHINO Works America Inc.

SE3000 series scanning units are designed for data logging with a personal computer. The basic unit with 6 input points can be connected to 7 sub units (6 input points / sub unit) and maximum 48 analog data can be collected. Two soft ware packages, "KIDS" for data logging and "PASS" for parameter... [See More]

  • Host Connection: RS232/422/485
  • Differential Channels: Yes
  • Analog Channels: 6
  • Accuracy: 0.1000
Data Collector -- LCOM
from LufftUSA

Description: The LCOM (Lufft-Communicator) is an industrial PC with the Windows-CE operating system. The following interfaces are available for communication purposes: USB, CDMA modem (RS232), Partyline modem (RS232) or UMB bus (RS485). Conversion to the following standard protocols can be made in... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Application: Environmental
  • Form Factor: Industrial PC
  • User Interface: Touch Screen
Instrumentation and Ultra-low Power Micro RTUs -- FloLog™ Gas Well Flow Logger
from Willowglen Systems Inc.

The Willowglen FloLog ™ Gas Well Flow Logger is a flexible, cost effective and extremely energy efficient solution for remote gas well Electronic Flow Measurement (EFM) applications. With its hazardous area certification and battery operation, the FloLog ™ device is ideal for use at well... [See More]

  • Host Connection: RS232/422/485
  • Form Factor: Stand-alone
  • Accuracy: 0.1500
  • Application: General Lab & Industrial
Streampix 5 with DAQ Module
from NorPix, Inc.

StreamPix is Norpix ’s flag ship software product. Resulting from more than 10 years of interaction with our vast group of customers, StreamPix has become the ultimate Digital Video Recording software. It offers a state of the art user interface, and an enormous amount of usage flexibility for... [See More]

  • Host Connection: RS232/422/485; Firewire; TTL; Ethernet
  • Differential Channels: Yes
  • Analog Channels: 32
  • Digital I/O Channels: 48
6-Axis Acceleration & Angular Rate Recorder, MotionMaster™ -- EDR-6DOF
from Instrumented Sensor Technology

Use IST's new MotionMaster ™ a portable accelerometer that ’s used as an acceleration data logger that has angular rate sensors and to characterize 6DOF motion environments of amusement rides, airborne vehicles, watercraft, underwater vehicles, vehicular crashes, shipping environments... [See More]

  • Host Connection: RS232/422/485; USB
  • Inputs: Accelerometer Input
  • Application: General Lab & Industrial; Vehicular
  • User Interface: None
Datalogger for Depth/Level Measurement with Conductivity Module -- STS DL/N
from PMC Engineering LLC

The DL/N series is part of a comprehensive range of transmitters specifically designed for the long term monitoring of ground water, wastewater and tank level measurement. The Series 70 provides a sophisticated datalogger which includes the monitoring of level, conductivity and temperature... [See More]

  • Host Connection: RS232/422/485
  • Application: General Lab & Industrial; Environmental; Weather / Meteorology
  • Accuracy: 0.2500
  • User Interface: None
Data Logger -- HL-NT3
from Rotronic Instrument Corp.

The HygroLog HL-NT humidity, dew point and temperature data logger can be used with any of the HygroClip 2 probes. The HL-NT can monitor up to 7 probes as well as up to two external on/off contacts, such a a door contact. When used together with the validated ROTRONIC HW4 software the HygroLog HL-NT... [See More]

  • Host Connection: RS232/422/485; USB
  • Application: General Lab & Industrial
  • Form Factor: Stand-alone
  • User Interface: Front Panel
Data Acquisition Module -- SDRlab 122-16 External Clock Standard Kit
from Red Pitaya, d.o.o.

SDRlab 122-16 External clock is based on the SDRlab 122-16 model that is modified to be used with an external clock oscillator, which is important especially for RF applications that operate at other frequencies, require better quality clock or clock synchronization. [See More]

  • Host Connection: RS232/422/485; USB; TTL; Ethernet; WiFi
  • Differential Channels: Yes (optional feature)
  • Analog Channels: 6
  • Digital I/O Channels: 16
Data logger NOVUS FieldLogger 8812120000 [8812120000 from Novus Automation, Inc.]
from Automation24, Inc.

Fieldlogger 8812120000 from NOVUS automation is a dynamic and versatile solution for keeping track of data points simultaneously, while also providing alarm outputs when needed. The 8812120000 data logger provides 8 digital input/output points, as well as 8 analog inputs and 2 relay outputs. The... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Ethernet, MODBUS (RS-485), USB
  • Resolution: 24
  • Digital I/O Channels: 8
  • Form Factor: DIN Rail; DIN rail
Compact Data Acquisition and Control System -- ADwin-X-A20
from CAS DataLoggers

CAS is pleased to announce the new ADwin-X-A20 compact data acquisition and control system. It features a high performance, dual-core, 64-bit processor plus analog and digital inputs and outputs and a 1GB Ethernet communications interface to provide extremely precise, low latency real-time... [See More]

  • Host Connection: RS232/422/485; USB; TTL; Ethernet
  • Differential Channels: Yes
  • Analog Channels: 8
  • Digital I/O Channels: 8
16 Channel Datalogger with SD Card -- Zen Datalogger
from Define Instruments

What it does: Enables sophisticated monitoring, control and data logging of up to 16 input signals from a variety of sources. Easy DAQ and onboard data logging. Get all your data acquisition (DAQ) requirements fulfilled with the Zen Datalogger. It logs data onto a 1GB micro SD card, so you can... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Digital I/O Channels: 4
  • Analog Channels: 16
  • Resolution: 16
Handheld Data Logger -- ProCheck
from Meter Group

The hand-held ProCheck gives you a read-out and stores reading from any of Decagon's soil moisture or environmental sensors. When you are using the ProCheck to read soil moisture sensors, you can pick from a list of supplied factory calibrations (both soil and soilless media) or input your own... [See More]

  • Host Connection: RS232/422/485
  • Application: Environmental
  • Form Factor: Stand-alone
  • User Interface: Front Panel; Hand-held Programmer
PIR2 - Personal iButton Serial # Recorder -- PIR2
from Embedded Data Systems

Traceability - every PIR2 has a unique serial number. Supports all Maxim/Dallas Semiconductor iButtons. Collects the time and iButton identity for touch events. Secure NV Memory capacity to hold 500 readings. Visual & auditory feedback ensures ease of use. High integrity data - all records... [See More]

  • Host Connection: RS232/422/485; USB; 1-Wire
  • Operating Temperature: -4 to 129
Data Logger -- LOGBOX SE
from Kipp & Zonen, Inc.

4 differential and 4 single-ended analogue inputs, 4 digital inputs. Connect up to 8 Kipp & Zonen Smart radiometers. Quad-band GSM/GPRS modem with external antenna. Send data to an e-mail address or FTP server. LOGBOX SE is a data logger with analogue and digital inputs that allow connection to... [See More]

  • Host Connection: RS232/422/485; USB
  • Differential Channels: Yes
  • Analog Channels: 4
  • Digital I/O Channels: 4
Data Logger -- RainLog™
from RainWise, Inc.

The RainWise RainLog data logger provides an economical method of logging rainfall at a remote location where power is not available. This battery operated logger fits inside our polypropylene rain gauge and will log total rainfall at a one minute resolution for up to one year. It can easily be... [See More]

  • Host Connection: RS232/422/485
  • Digital I/O Channels: 0
  • Analog Channels: 1
  • Form Factor: Stand-alone
Datalogger for Measurement & Control -- CR5000
from Campbell Scientific, Inc.

The CR5000 is a rugged, high performance, integrated datalogger/data acquisition system with a built-in keyboard, graphics display, and PCMCIA card slot. It combines 16-bit resolution with a maximum throughput of 5000 measurements per second. The CR5000 is available with a built-in sealed... [See More]

  • Host Connection: RS232/422/485
  • Digital I/O Channels: 8
  • Differential Channels: Yes
  • Resolution: 16
Process Data Logger -- Model PDL
from OTEK Corporation

OTEK's Process Data Logger PDL (3.78"W x 3.78"H x 3"D) was specifically designed to satisfy the need for long term and capacity data logging in "burn in" ovens for the semiconductor industry, as well as other high reliability applications. The PDL is loaded with the latest technology (ARM7... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Differential Channels: Yes
  • Analog Channels: 48
  • Form Factor: Modular Bay or Slot System
Data-Chart Paperless Recorder Series -- DC2000
from Monarch Instrument

If you demand: Higher reliability. Increased flexibility. Optimum efficiency. Lower costs. DataChart 2000 Series Paperless Recorders are the instruments for you!. Overview. The Data-Chart 2000 has 2, 4, 6 or 12 direct universal isolated inputs that are menu selectable for DC voltage, DC current,... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • Sampling Frequency: 0.0080
  • Analog Channels: 12
  • Resolution: 16
1/8 DIN 6-Digit Rate Meter/Totalizer -- DPF701
from OMEGA Engineering, Inc.

The DPF701 Series ratemeter/ totalizer offers user programming via the 5 front-panel keys. Scale factor may be programmed from -99,999 to 999,999 (any decimal point, multiply or divide), while offset may be programmed from -99,999 to 999,999 (any decimal point). Programs are stored in non-volatile... [See More]

  • Host Connection: RS232/422/485; TTL
  • Sampling Frequency: 30
  • Analog Channels: 1
  • Accuracy: 1
OMNIAlog Logger MI400 MAVT GPRS
from Next Industries S.r.L

The OMNIAlog MI400 MAVT is an ultra low powered logger with integral modem designed specifically for remote applications. The next step up from the MI400 MAV, it has more analogue inputs and Modbus slave capabilities. 4 differential software programmable analog input. Each of the 4 channels offers... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Differential Channels: Yes
  • Analog Channels: 4
  • Digital I/O Channels: 0
Process Instrumentation, Process Recorders, SIREC D300 Recorder
from Siemens Process Instrumentation

The SIREC D300 is a multi-functional 144 mm x 144 mm display recorder with 8 to 16 analog channels and up to 16 digital channels. The wide range of SIREC D products accommodates continuous monitoring, system maintenance, process optimization and troubleshooting requirements. Fast scanning rate of 20... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Digital I/O Channels: 16
  • Analog Channels: 16
  • Sampling Frequency: 0.0020
Dual-line Flow Rate/Totalizers -- Model PD6200
from Clark Solutions

Simultaneous display of rate and total makes the 2-line PD6200 Rate/Totalizer an ideal choice for flow applications. The PD6200 may be configured for a variety of analog input signals, while the PD6300 will take pulse input signals. Via the UV-resistant, NEMA 4X front panel, the main and secondary... [See More]

  • Host Connection: RS232/422/485
  • Form Factor: DIN Rail
  • Analog Channels: 1
  • Application: General Lab & Industrial
DataVU 5 Paperless Chart Recorder
from West Control Solutions

The DataVU 5 paperless recorder is designed to provide a fast and easy set up through user friendly controls. Set up is so simple that it can be carried out on the spot via the front panel without the need for a PC. Configuration is carried out using a combination of fixed keys and menu led soft... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Profibus-DP
  • Digital I/O Channels: 4
  • Analog Channels: 6
  • Form Factor: Panel / Chassis Mount
Data Logger with Server -- SM61
from Sifam Tinsley UK

Features. • Visualisation of current and archived data according to customer configuration (synoptic maps, charts, tables) by any web browser. • Readout up to 2500 values from slave devices (up to 100 devices, each 25 registers). • User-friendly application for data configuration. [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Form Factor: DIN Rail
  • Analog Channels: 2
  • Inputs: Binary
Multifunction Meters - PMD Energy Monitoring and Event Analysis -- DIRIS A60
from SOCOMEC

DIRIS A60 is a panel mounted multifunction meter which incorporates all functions of the DIRIS A40 with the addition of enhanced data logging functions, recording curves for quality events. All this information can be analysed remotely using the Analysis software which is available at no charge and... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • Form Factor: Panel / Chassis Mount
  • Accuracy: 0.2000
  • Outputs: Analog Voltage Output; Frequency or Pulse Output
Handy Logger -- MR2041 Series
from CHINO Works America Inc.

Handy logger MR2041 is a palm size data logger, it capable to store up to 10000 data per each channel. Power supply of logger is selectable from AA battery or AC adaptor, so it is usable as a portable type logger or fixing type logger. Using the exclusive software, recording/recalling of data and... [See More]

  • Host Connection: RS232/422/485
  • Sampling Frequency: 1.00E-3
  • Analog Channels: 4
  • Accuracy: 0.1000
Data Collector for External Sensor -- OPUS20E
from LufftUSA

Description: The Opus20E offers the highest flexibility and is excellent value for money. It allows the connection of up to 4 external temperature and relative humidity sensors, as well as 2 further analogue sensors. Intelligent BUS sensors can be integrated via the OPUS20E ’s RS485 interface... [See More]

  • Host Connection: RS232/422/485; USB
  • Application: Environmental
  • Form Factor: DIN Rail
  • DC Voltage: 0-1V
Shock & Vibration Sensor / Recorder / Logger / Monitor -- EDR-4
from Instrumented Sensor Technology

Triggered Waveform Recording. 3 & 6 - Channel Capabilities. 12-bit A/D, 74dB Dynamic Range. Programmable Digitization to 15 KHz/CH. Three Single-Ended Inputs. Three Differential Inputs. Internal PR Triaxial Accelerometer (Rentals Offered). Constant-Current Excitation For Low-Bias PE Accels. User... [See More]

  • Host Connection: RS232/422/485; Parallel
  • Inputs: Accelerometer Input
  • Application: General Lab & Industrial; Vehicular
  • User Interface: None
Miniature Submersible Datalogger Level Transmitter -- DL-MTM3211
from PMC Engineering LLC

The PMC Water Level Datalogger is a simple, effective and economical system designed to measure water level using a datalogger and pressure sensor. The Water Level Datalogger is valuable in level monitoring applications such as aquifer characterization, environmental remediation, well or tank level... [See More]

  • Host Connection: RS232/422/485
  • Application: General Lab & Industrial; Environmental; Marine; Weather / Meteorology
  • Accuracy: 0.2500
  • User Interface: None
Data Acquisition Module -- SDRlab 122-16 Standard Kit
from Red Pitaya, d.o.o.

SDRlab 122-16 was developed specifically for software-defined radio and more demanding RF applications. [See More]

  • Host Connection: RS232/422/485; USB; TTL; Ethernet; WiFi
  • Differential Channels: Yes (optional feature)
  • Analog Channels: 6
  • Digital I/O Channels: 16
Data logger NOVUS FieldLogger 8812120004 [8812120004 from Novus Automation, Inc.]
from Automation24, Inc.

Fieldlogger 8812120004 from NOVUS automation is a dynamic and versatile solution for keeping track of data points simultaneously, while also providing alarm outputs when needed. An exclusive color HMI can be attached or remotely installed for local indication or configuration. The 8812120004 data... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Ethernet RJ45, Mobbus (RS485), USB
  • Digital I/O Channels: 8
  • Analog Channels: 8
  • Resolution: 24
Data Acquisition System – Network Compatible and Modular -- Delphin ProfiMessage
from CAS DataLoggers

The Delphin ProfiMessage Data Acquisition System is a modular device for data acquisition and automation. A master/slave design makes ProfiMessage suitable for both small and large applications that require the processing of thousands of channels. Master and slave devices can each accommodate two... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Radio
  • Differential Channels: Yes
  • Analog Channels: 15
  • Sampling Frequency: 160
Solar Powered Data Logger -- EM5b
from Meter Group

The Em5b is a five-channel mini-logger for use with select ECH2O sensors*. It is a low-cost, limited-use alternative to the Em50 datalogger. The Em5b uses 4 AAA-size alkaline batteries, which should last 5-6 months, and has 49K of Flash Data memory (145 days at 1 scan/hour). The Em5b comes with... [See More]

  • Host Connection: RS232/422/485
  • Form Factor: Stand-alone
  • Analog Channels: 5
  • Application: Environmental
Display Console -- S-12
from RainWise, Inc.

Display Console and Data Logger. The WeatherLog ® System 12 Control/Display Console was developed to meet those applications which require a large number of sensors and/or a number of extra display parameters, such as averaging, daily records, etc. Product Features. The System 12 has two serial... [See More]

  • Host Connection: RS232/422/485
  • Application: Environmental; Weather / Meteorology
  • Form Factor: Stand-alone
  • Outputs: Analog Current Output (optional feature)
Datalogger for Satellite Communication -- CR295X
from Campbell Scientific, Inc.

Campbell Scientific replaced the CR200-series dataloggers with the CR200X-series dataloggers. The new dataloggers feature expanded memory for the program and operating system (OS). The expanded memory allows: Up to 128 public variables instead of 48. Up to eight tables instead of four. Compiled... [See More]

  • Host Connection: RS232/422/485
  • Form Factor: Panel / Chassis Mount
  • Analog Channels: 8
  • Application: General Lab & Industrial
DataChart® Advanced Paperless Data Acquistion System -- DC6000
from Monarch Instrument

The DataChart 6000 is the most advanced paperless recording system available. It incorporates the latest in measurement, communication, interface and processing technologies to deliver unmatched performance for your data acquisition application. The Data Chart 6000 is like no other paperless... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Digital I/O Channels: 12
  • Analog Channels: 12
  • Sampling Frequency: 0.0100
12-Channel RTD Input Data Acquisition Module -- RDXL4SD
from OMEGA Engineering, Inc.

The portable RDXL4SD (accepts t/c or RTD) and RDXL12SD (accepts t/c input only) models are handheld thermometer/data loggers with backlight display and built-in analysis functions. The data loggers are powered by an internal battery and are capable of sampling, processing and displaying measurements... [See More]

  • Host Connection: RS232/422/485; USB
  • Form Factor: Portable
  • Analog Channels: 4
  • Application: General Lab & Industrial; Weather / Meteorology
OMNIAlog Logger MI480
from Next Industries S.r.L

The OMNIAlog MI480 is a smart datalogger that provides an extensive array of features that allow it to be used across a wide variety of applications. The MI480 is a robust, stand alone, low power data logger featuring USB memory stick support, 24 bit resolution, extensive communications capabilities... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Differential Channels: Yes
  • Analog Channels: 8
  • Digital I/O Channels: 2
Process Instrumentation, Process Recorders, SIREC D400 Recorder
from Siemens Process Instrumentation

The SIREC D400 is a high-end 300 mm x 300 mm XGA display recorder with 16 to 48 analog channels and up to 48 digital channels. The wide range of SIREC D products accommodates continuous monitoring, system maintenance, process optimization and troubleshooting requirements. Fast scanning rate of 20 /... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Digital I/O Channels: 48
  • Analog Channels: 48
  • Sampling Frequency: 0.0020
DataVU 7 Paperless Chart Recorder
from West Control Solutions

DataVU 7 provides advanced flexibility to meet a user ’s specific requirements without the need to change a process to fit the recorder. If process requirements are subject to change at a later date then the user benefits from the ease with which modifications can be made to the recorder... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Profibus-DP
  • Digital I/O Channels: 24
  • Analog Channels: 24
  • Form Factor: Panel / Chassis Mount
Digital Panel Recorder -- N30B
from Sifam Tinsley UK

Features. • Data readout and recording from devices with RS485 interface and Modbus RTU protocol. • 2 x RS485 interface with Modbus RTU protocol (Master and Slave). • 3-colour display (14 mm height), programmable in 3 ranges of the displayed value. • 21-point individual... [See More]

  • Host Connection: RS232/422/485; MODBUS
  • Form Factor: Rack Mount
  • Analog Channels: 2
  • Inputs: RS-485, MODBUS
Hybrid Memory Recorders -- AH4000 Series
from CHINO Works America Inc.

AH4000 series is a hybrid recorder which employs bright and clear, easy to view LCD display. Measuring value display is prepared as 1 point display, multi-points simultaneous display and digital display + bar graph display. Various measuring and recording settings can be easily done by front key... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • Form Factor: Stand-alone
  • Analog Channels: 24
  • Application: General Lab & Industrial
Shock, Vibration & Environmental Recorder -- EDR-3C
from Instrumented Sensor Technology

Our portable impact, shock and vibration recorder has a built-in tri-axial accelerometer along with many other features including easy setup and use and can be battery powered for over thirty days, onboard memory and more. Highlights: Measures Shock, Vibration & Temperature. Options for... [See More]

  • Host Connection: RS232/422/485; USB
  • Inputs: Accelerometer Input
  • Application: General Lab & Industrial; Vehicular
  • User Interface: None
Data Acquisition Module -- SIGNALlab 250-12 OEM
from Red Pitaya, d.o.o.

SIGNALlab 250-12 is most sophisticated Red Pitaya product, built for more demanding industrial applications and research, where robustness and performance matter more than cost. [See More]

  • Host Connection: RS232/422/485; USB; TTL; Ethernet; WiFi
  • Differential Channels: Yes (optional feature)
  • Analog Channels: 6
  • Digital I/O Channels: 16
Data logger NOVUS FieldLogger 8812130000 [8812130000 from Novus Automation, Inc.]
from Automation24, Inc.

Fieldlogger 8812130000 from NOVUS automation is a dynamic and versatile solution for keeping track of data points simultaneously, while also providing alarm outputs when needed. The 8812130000 data logger provides 8 digital input/output points, as well as 8 analog inputs and 2 relay outputs. The... [See More]

  • Host Connection: RS232/422/485; USB; MODBUS (RS-485), USB
  • Resolution: 24
  • Digital I/O Channels: 8
  • Form Factor: DIN Rail; DIN rail
Environmental Data Logger -- dataTaker® DT82E
from CAS DataLoggers

The Environmental Data Logger. The dataTaker DT82E is an intelligent data logger that was designed with environmental applications in mind. The DT82E is a robust, stand alone, low power data logger featuring USB memory stick support, 18 bit resolution, extensive communications capabilities and... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Modem
  • Digital I/O Channels: 4
  • Analog Channels: 6
  • Sampling Frequency: 0.0250
Electronic Data Logger -- EDL
from RainWise, Inc.

The EDL is an electronic data logger incorporating non-volatile memory and a low power or "sleep" mode. The logger accepts Rainwise sensors. The RainWise EDL logger incorporates a real time clock, 128K, 256K, 512K and 1MB bytes of Static non-volatile data RAM. Data save intervals are user selectable... [See More]

  • Host Connection: RS232/422/485
  • Differential Channels: Yes
  • Analog Channels: 8
  • Digital I/O Channels: 3
Datalogger with 2.4-GHz Radio -- CR216X
from Campbell Scientific, Inc.

Campbell Scientific replaced the CR200-series dataloggers with the CR200X-series dataloggers. The new dataloggers feature expanded memory for the program and operating system (OS). The expanded memory allows: Up to 128 public variables instead of 48. Up to eight tables instead of four. Compiled... [See More]

  • Host Connection: RS232/422/485; Radio
  • Form Factor: Panel / Chassis Mount
  • Analog Channels: 8
  • Application: General Lab & Industrial
Compact Portable Data Logger -- RDXL120
from OMEGA Engineering, Inc.

The channels in the analog input part adopt insulated inputs, which means that temperature (thermocouple/resistance temperature detector) and voltage can be set differently for each channel. Eleven types of thermocouples, Pt100 and JPt100 temperature-measuring resistors, and a voltage up to 50V... [See More]

  • Host Connection: RS232/422/485; Ethernet
  • Accuracy: 0.1000
  • Analog Channels: 10
  • Form Factor: Portable
OMNIAlog Logger MI816C
from Next Industries S.r.L

The OMNIAlog MI816 is a smart datalogger that provides an extensive array of features that allow it to be used across a wide variety of applications. The MI816C is a robust, stand alone, low power data logger featuring USB memory stick support, 24 bit resolution, extensive communications... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet
  • Differential Channels: Yes
  • Analog Channels: 16
  • Digital I/O Channels: 2
Screen Recorder -- KD7
from Sifam Tinsley UK

Features. • Visualisation of current and archived data according to customer configuration (synoptic maps, charts, tables) by any web browser. • Readout up to 2500 values from slave devices (up to 100 devices, each 25 registers). • User-friendly application for data configuration. [See More]

  • Host Connection: RS232/422/485; USB
  • Digital I/O Channels: 16
  • Analog Channels: 12
  • Form Factor: Panel / Chassis Mount
Temperature Card Logger -- MR5300 Series
from CHINO Works America Inc.

Model MR5300 is a small size and lightweight card logger capable to store up to 6000 temperature data, and is washable (IP64 - splash proof). [See More]

  • Host Connection: RS232/422/485
  • Sampling Frequency: 1.00E-4
  • Analog Channels: 1
  • Form Factor: Stand-alone
Data Acquisition Module -- SIGNALlab 250-12 Standard Kit
from Red Pitaya, d.o.o.

SIGNALlab 250-12 is most sophisticated Red Pitaya product, built for more demanding industrial applications and research, where robustness and performance matter more than cost. [See More]

  • Host Connection: RS232/422/485; USB; TTL; Ethernet; WiFi
  • Differential Channels: Yes (optional feature)
  • Analog Channels: 6
  • Digital I/O Channels: 16
Paperless datalogger Endress+Hauser Ecograph T RSG35
from Automation24, Inc.

The Ecograph T RSG35 data logger from Endress+Hauser is used to securely and completely record and visualise all process sequences. Because every measured value counts, the universal data logger records, visualises and monitors all analogue or digital input signals. The measured values are displayed... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Ethernet, RS232, RS485, USB
  • Digital I/O Channels: 6
  • Analog Channels: 12
  • Resolution: 24
Environmental Data Logger with Modem -- dataTaker® DT82EM
from CAS DataLoggers

Internal GSM Modem. The dataTaker DT82EM is an intelligent data logger that incorporates a built-in GSM modem with email and SMS support for automated data and alarm transfer from remote sites. The DT82EM features USB memory stick support, 18 bit resolution, extensive communications capabilities and... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Modem
  • Digital I/O Channels: 4
  • Analog Channels: 2
  • Sampling Frequency: 0.0250
Enhanced Computer Interface and Weather Data Logger -- CC-3000
from RainWise, Inc.

The CC-3000 is our next generation data logger and computer interface. Connectivity, storage capacity and features have all been enhanced. The CC-3000 replaces the CC-2000 and MKIIICC interface. Please be sure to select the model that matches your weather station. Long range versions support LR... [See More]

  • Host Connection: RS232/422/485; USB
  • Application: Environmental
  • Form Factor: Stand-alone
  • User Interface: Computer Programmable
Datalogger With 915-MHz Radio -- CR206X
from Campbell Scientific, Inc.

Campbell Scientific replaced the CR200-series dataloggers with the CR200X-series dataloggers. The new dataloggers feature expanded memory for the program and operating system (OS). The expanded memory allows: Up to 128 public variables instead of 48. Up to eight tables instead of four. Compiled... [See More]

  • Host Connection: RS232/422/485; Radio
  • Form Factor: Panel / Chassis Mount
  • Analog Channels: 8
  • Application: General Lab & Industrial
Counter / Totalizer / Event Data Logger -- OM-CP-PULSE101 / OM-CP-PULSE110
from OMEGA Engineering, Inc.

The OM-CP-PULSE101 and OM-CP-PULSE110 are low-cost recording devices that will sense a pulse input or contact closure from external sources such as transducers or pulse initiators (gas, water, and electric meters) and transform those inputs into engineering units. In addition, these dataloggers... [See More]

  • Host Connection: RS232/422/485; USB; TTL
  • Form Factor: Screw Mount
  • Digital I/O Channels: 1
  • Application: General Lab & Industrial
Two-Channel Card Logger -- MR5320 Series
from CHINO Works America Inc.

Model MR5320 is a small size and lightweight 2-channel card logger capable to monitor temperature in two places and store up to 6000 data per channel, and is washable (IP64 - splash proof). [See More]

  • Host Connection: RS232/422/485
  • Sampling Frequency: 1.00E-4
  • Analog Channels: 2
  • Form Factor: Stand-alone
Data Acquisition Module -- STEMlab 125-14 4-Input Starter Kit
from Red Pitaya, d.o.o.

STEMlab 125-14 4 Inputs is based on STEMlab 125-14 board, but instead of 2 inputs and 2 output channels offers 4 Input channels that with improved performance. [See More]

  • Host Connection: RS232/422/485; USB; TTL; Ethernet; WiFi
  • Differential Channels: Yes (optional feature)
  • Analog Channels: 8
  • Digital I/O Channels: 20
Industrial Data Logger -- dataTaker® DT82i
from CAS DataLoggers

The Industrial Data Logger. The dataTaker DT82I was designed for industrial applications that focus on flexible serial type communications such as RS232, RS422 and RS485. The DT82i is a robust, stand alone, low power data logger featuring USB memory stick support, 18 bit resolution, extensive... [See More]

  • Host Connection: RS232/422/485; USB; Ethernet; Modem
  • Digital I/O Channels: 4
  • Analog Channels: 6
  • Sampling Frequency: 0.0250
Long Range Computer Interface -- MKIIICC-LR
from RainWise, Inc.

Long Range Computer Interface. The MKIIICC-LR computer interface is a device that will record and store weather data received from MK III sensor assemblies. The MKIIICC-LR has 32K of memory which allows the device to log data independently of a computer for 3 months. Connecting the Wireless Computer... [See More]

  • Host Connection: RS232/422/485; Radio
  • Digital I/O Channels: 0
  • Analog Channels: 1
  • Form Factor: Stand-alone
Datalogger With 922-MHz Radio -- CR211X
from Campbell Scientific, Inc.

Campbell Scientific replaced the CR200-series dataloggers with the CR200X-series dataloggers. The new dataloggers feature expanded memory for the program and operating system (OS). The expanded memory allows: Up to 128 public variables instead of 48. Up to eight tables instead of four. Compiled... [See More]

  • Host Connection: RS232/422/485; Radio
  • Form Factor: Panel / Chassis Mount
  • Analog Channels: 8
  • Application: General Lab & Industrial
Event Data logger -- OM-CP-EVENT101 / OM-CP-EVENT110
from OMEGA Engineering, Inc.

#162;Memory: 13,107 Time Stamped Events. ¢Miniature Size. ¢Memory Wraparound. ¢Interfaces to Tipping Bucket Rain Gages and Other Devices with TTL Pulse, Contact Closure Output. ¢Real-Time Operation. ¢Operational in Minutes. The OM-CP-EVENT101 and OM-CP-EVENT110 are low-cost... [See More]

  • Host Connection: RS232/422/485; USB
  • Form Factor: Stand-alone
  • Analog Channels: 1
  • Application: General Lab & Industrial