100 Ohms RTD Temperature Transmitters
from Dataforth Corporation
Each DSCP20 2-wire transmitter is designed for measuring temperature using thermocouples or RTDs. The input type, measurement range, and other features are software configurable. A PC, the DSCX-887 and DSCX-416 interface cables, and the DSCX-895 configuration software are required to configure the... [See More]
- Reference Resistance: 100 Ohms; 50 Ohms
- Sensed Temperature: -328 to 3308
- Reference Material: Platinum; Nickel/Nickel Alloys; Copper
- Mounting Options: DIN Rail Mounting
from RS Components, Ltd.
digital, programmable transmitter for Pt [See More]
- Reference Resistance: 100 Ohms; 1000 Ohms; Ni100, Pt100, Pt1000
- Operating Temperature: -40 to 185
- Reference Material: Platinum; Nickel/Nickel Alloys
from Pyromation
Fixed-Sheath RTD Assemblies with the wireless cellular transmitters are provided with a variety of design options listed below. The self-contained, battery-powered cellular transmitter utilizes LTE-M/NB-IoT technology to bring temperature data directly to the cloud. Data is transmitted over cellular... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 1112
- Reference Material: Platinum
- Local Interface: Computer Interface
from ABB Measurement & Analytics
The field-mount temperature transmitter TTF200 is provided for all HART standard applications in temperature measurement with one sensor. The transmitter supports the same functionality as the TTF300, but without sensor redundancy and sensor drift monitoring. It can be configured with ABB-tools such... [See More]
- Reference Resistance: 100 Ohms
- Mounting Options: Field Mounted
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Conax Technologies
RTD, TC, Ohm, or mV Input. Extremely High Measurement Accuracy. HART ® Communication. Complies with European ATEX, and CSA/FM Requirements for Hazardous Location Installation. 1- or 2-Channel Version. Application: Linearized temperature measurement with Pt 100...Pt 1000, Ni100...Ni1000, or TC... [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 120 Ohms; 200 Ohms; 400 Ohms; 500 Ohms; 1000 Ohms; 7000 Ohms Max.
- Other Input: Accepts Generic Resistance Inputs
- Reference Material: Platinum; Nickel/Nickel Alloys
- Sensed Temperature: -328 to 4172
from Dataforth Corporation
Each DSCT34 RTD input transmitter provides a single channel of RTD input which is filtered, isolated, amplified, linearized, and converted to a process current output. Signal filtering is accomplished with a five-pole filter, which provides 85dB of normal-mode rejection at 60Hz and 80dB at 50Hz. An... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -148 to 212
- Reference Material: Platinum
- Mounting Options: Modular
from Pyromation
Heat-tracing RTDs with wireless cellular transmitters are made for use in systems that measure the surface temperature of process piping to prevent freeze-up, or to maintain a viscosity level so that the inner medium will continuously flow. They are offered in a variety of accuracies, sheath lengths... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 1112
- Reference Material: Platinum
- Local Interface: Computer Interface
from ABB Measurement & Analytics
The TTH200 is provided for all HART standard applications in temperature measurement with one sensor input. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. The TTH200 supports the same functionality as the TTH300, but without sensor redundancy and sensor drift monitoring. As... [See More]
- Reference Resistance: 100 Ohms
- Mounting Options: Head Mount
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Conax Technologies
RTD, TC, Ohm, or mV Input. Extremely High Measurement Accuracy. 1.5 kVAC Galvanic Isolation. Programmable Sensor Error Value. Application: Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor. Conversion of linear resistance variation to a standard analog current... [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 120 Ohms; 200 Ohms; 400 Ohms; 500 Ohms; 1000 Ohms; 5000 Ohms Max.
- Other Input: Accepts Generic Resistance Inputs
- Reference Material: Platinum; Nickel/Nickel Alloys
- Sensed Temperature: -328 to 4172
from Dataforth Corporation
Each DSCP55 RTD Loop-Powered Converter provides a single channel of RTD input which is amplified, linearized and converted to a high-level 4 to 20mA or 20 to 4mA output. Inputs may be connected by 2, 3, or 4 wires and measurement range may be configured by dip-switch. [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 1202
- Reference Material: Platinum; Nickel/Nickel Alloys
- Mounting Options: DIN Rail Mounting
from Pyromation
Remote-mount RTD assemblies with the wireless cellular transmitters are designed for applications where space is limited, or where high ambient temperatures or excessive heat conduction exists. These assemblies are provided with a variety of design options listed below. The self-contained,... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 1112
- Reference Material: Platinum
- Local Interface: Computer Interface
from ABB Measurement & Analytics
The TTR200 is a rail-mount version of the TTH200 transmitter with the addition of two indicator LEDs. A green LED indicates that the transmitter is powered. A red LED would indicate a fault in either the unit or the sensor. TTR200 units can be placed in cabinet racks. It can be configured with... [See More]
- Reference Resistance: 100 Ohms
- Mounting Options: DIN Rail Mounting
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Conax Technologies
Programmable LED Indicator, 2 Relay, Front Key Programmable – Model 5714. * 4-Digit, 14-Segment LED Indicator. * Input for RTD, TC, mA, V, and Potentiometer. * Universal Supply Voltage. * Front Key Programmable. * Available with Optional 2 Relays and Analog Output. Application: * Display for... [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 200 Ohms; 400 Ohms; 500 Ohms; 1000 Ohms; 20, 50, 250 Ohms
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
- Reference Material: Platinum; Nickel/Nickel Alloys
- Sensed Temperature: -328 to 4172
from Pyromation
Spring-Loaded RTD/Thermowell Assemblies with a wireless cellular transmitter are designed for use with various thermowell types. The selfcontained, battery-powered cellular transmitter utilizes LTE-M/NB-IoT technology to bring temperature data directly to the cloud. Data is transmitted over cellular... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 1112
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from ABB Measurement & Analytics
The WirelessHART technology features a multitude of new functions and enhanced diagnostic information. Unique driver-independent configuration of the transmitter via push buttons and LCD display. [See More]
- Reference Resistance: 100 Ohms
- Mounting Options: Field Mounted
- Reference Material: Platinum
- Local Interface: Digital Front Panel
from Conax Technologies
Programmable LED Indicator, 4 Relay, Front Key and PC Programmable Model 5715. * 4-Digit, 14-Segment LED Indicator. * Input for RTD, TC, mA, V, and Potentiometer. * 4 Relays with Optional Analog Output. * Universal Supply Voltage. * Programmable via Front Keypad or PC. Application: * Display for... [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 200 Ohms; 400 Ohms; 500 Ohms; 1000 Ohms; 20, 50, 250 Ohms
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
- Reference Material: Platinum; Nickel/Nickel Alloys
- Sensed Temperature: -328 to 4172
from OMEGA Engineering, Inc.
The CYTX231 temperature transmitters send linearized data to a remote location for a data acquisition system or a recorder using a 4-20 or 0-20mA signal. Standard Curve #10 chart shown in the T section is in memory for the silicon diode sensor and excitation of 10A is provided. The CYTX231P operates... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -457 to 980
- Reference Material: Platinum; Other (Tungsten, Silver etc.)
- Mounting Options: Cabinet (Enclosure) or Board Mounting
from Burkert Fluid Control Systems
This intelligent threshold detector/transmitter with an extra large display is specifically designed to monitor limit values or an ON/OFF or continuous control loop. Two versions are available: the 8400 Compact and 8400 for wall mounting. The wall-mounted version must be inserted into a holder... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -40 to 257
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA); Relay or Switch Output
from Alfa Laval Inc.
Temperature transmitters provide accurate and reliable temperature measurement in hygienic and pharmaceutical production. Fast, accurate temperature measurement. Alfa Laval temperature transmitters are compact hygienic measuring devices that provide accurate temperature measurement. Temperature... [See More]
- Reference Resistance: 100 Ohms
- Output: Analog Current (Typical 4-20 mA); Relay or Switch Output
- Reference Material: Platinum
- Local Interface: Computer Interface
from Chromalox
Wireless is rapidly becoming the preferred sensing technology of choice in many commercial and industrial systems. Wireless sensing can greatly reduce installation costs and more easily solve geographically and structurally challenging sensing applications. Chromalox now provides fully integrated... [See More]
- Reference Resistance: 100 Ohms
- Output: Other Output Option
from NOSHOK, Inc.
The NOSHOK Series 800 temperature transmitter provides an unbeatable level of performance at an economical price. Using the proven reliability and stability of 100 ohm platinum resistance technology, this transmitter offers a broad array of choices for the OEM and user alike. A rigorous test and... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -40 to 1000
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from Ultra Energy
4500H Temp Transmitter, Industrial Temperature Transmitter, Head Mount RTD [See More]
- Reference Resistance: 100 Ohms; 500 Ohms; 1000 Ohms
- Sensed Temperature: -328 to 1202
- Reference Material: Platinum; Nickel/Nickel Alloys
- Output: Analog Current (Typical 4-20 mA)
from Winters Instruments
Description & Features: • A sensitive temperature sensor designed to transmit an electronic signal to a remote location • NEMA4 stainless steel or aluminum head • Platinum element • Various stem lengths available • ±0.12% accuracy • 1 year... [See More]
- Reference Resistance: 100 Ohms
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Azbil Corporation
These compact and lightweight smart temperature transmitters receive thermocouple input, RTD input, or mV input and transmit it as a 4 –20 mA DC or degital signal. They can be used with general-purpose signal cables, similar to other transmitters for flow or pressure measurement, eliminating... [See More]
- Reference Resistance: 100 Ohms; 200 Ohms; 500 Ohms; 1000 Ohms
- Other Input: Accepts Generic Analog Voltage Inputs
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from R. STAHL, Inc.
One unit for nearly all temperature sensors indivdually configurable. Intrinsically safe input [Ex ia] IIC. Signal duplication possible. Galvanic isolation between input, output, power supply and configuration interface. Open-circuit and short-circuit monitoring and messaging (can be switched off). [See More]
- Reference Resistance: 100 Ohms; 500 Ohms; 1000 Ohms; ThermoCouple L, U, XK
- Sensed Temperature: -328 to 3213
- Reference Material: Platinum; Nickel/Nickel Alloys
- Mounting Options: DIN Rail Mounting
from Sitron
The robust and compact Pt10 Temperature Sensor in 316 Stainless Steel has a Pt100 RTD platinum sensor inserted into the rod with optimum accuracy and stability. The platinum RTD has the function of converting the measured temperature in the process to resistance in a proportional way with precision. [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -148 to 392
- Reference Material: Platinum
- Output: Other Output Option
from E+E Elektronik
Analogue, digital or passive room temperature sensors for residential and commercial HVAC. The very stylish EE10-T enclosure is available in European and US size and in several colors. The snap-on concept allows for easy installation. The active part of the device can be replaced within seconds... [See More]
- Reference Resistance: 100 Ohms; 1000 Ohms
- Sensed Temperature: 32 to 122
- Reference Material: Platinum
- Mounting Options: Cabinet (Enclosure) or Board Mounting
from Acrolab Ltd.
Explosion Proof Fixed Element RTD ’s are for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device eliminating the potential for ignition of ammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependent on connection head... [See More]
- Reference Resistance: 100 Ohms
- Output: Analog Current (Typical 4-20 mA)
- Reference Material: Platinum
from Status Instruments, Inc.
The SEM310 is a field mount temperature transmitter designed to replace the terminal block in a sensor head. It is fully encapsulated to ensure environmental integrity. Although small in size it out performs other larger and more expensive transmitters. Also available in DIN rail mount format... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 3200
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style); DIN Rail Mounting (optional feature)
from PR electronics
RTD, TC, Ohm, or mV input. Extremely high measurement accuracy. HART ® 5 protocol. Galvanic isolation. 1- or 2-channel versionng [See More]
- Reference Resistance: 100 Ohms; 1000 Ohms
- Output: Analog Current (Typical 4-20 mA)
- Reference Material: Platinum; Nickel/Nickel Alloys
- Supply Voltage: 8.0...35 VDC
from FineTek
TRX Temperature Transmitter. 。Supply Voltage: Loop Power 18~32 Vdc. 。DCV Input: 0~500 mV/ 0~1V/ 0~5V/ 0~10V/ 0~20V. 。DCA Input: 0~20 mA/ 4~20 mA. 。Thermocouple Input: K / J / T / E / R / S / B / N. 。RTD/ Resistance Input: PT100/0~400W. 。Analog Output: 4~20... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -4 to 140
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Acromag, Inc.
Thermocouple (J, K, T, R, S, E, B, N), RTD (Pt, Ni, Cu), millivolt ( ±100mV DC), 0 to 500 ohms input. 0 to 20mA DC, 0 to 10V DC output. Mechanical relay (25V @ 5A) alarm. 10-36V DC power. Software configured. Performs linearization, square root extraction, and optional limit alarm functions. [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 120 Ohms; 500 Ohms
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs
- Reference Material: Platinum; Nickel/Nickel Alloys; Copper
- Sensed Temperature: -382 to 1562
from Automation24, Inc.
The Pt100 temperature sensor iTHERM TM101-AABAA1GC1A2A1 from Endress+Hauser offers reliable temperature measurement with fundamental sensor technology and a fixed, non-interchangeable insert. The temperature sensor with a measurement range of -58 to 392 °F comes with a terminal block electrical... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -58 to 392
- Reference Material: Platinum
- Supply Voltage: 1/2" NPT Male
from Siemens Process Instrumentation
SITRANS TH100 provides a low-cost alternative for Pt100 measurements and offers economic plant operation and reliable measurements. Setup is quick and easy with the transmitter modem and SIPROM T. This configuration tool can be downloaded for free. Measures temperature with a linear output signal. [See More]
- Reference Resistance: 100 Ohms
- Output: Analog Current (Typical 4-20 mA)
- Reference Material: Platinum
from West Control Solutions
The microprocessor-controlled KS 816 controller provides precise, low-cost multi-loop control of temperature and features an interface for bus or field-bus. The KS 816 can be used as a freely configurable field-bus transmitter with universal inputs for standard signals, thermocouples and Pt 100... [See More]
- Reference Resistance: 100 Ohms
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Analog Current Inputs; Accepts Generic Resistance Inputs
- Reference Material: Platinum
- Sensed Temperature: -328 to 4172
from ifm electronic gmbh
Hygienic and robust design. Particularly space-saving design. Safe sealing in the process. Adapters for all standard process connections [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: 32 to 212
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Durex Industries
Durex offers a two-wire universal head transmitter for installation in our DIN B Terminal Heads. These transmitters are configured by Durex to convert the signal from any type Thermocouple or RTD (2, 3 or 4 wire) into a linearized and isolated 4-20 mA signal. [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -58 to 1112
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from Trafag Inc.
Main Features. Excellent long term stability. Protection IP65. EMC protection. Meets IEC 60571 (railways) [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -58 to 752
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Micro Sensor Co., Ltd.
MTM4831 can directly measure the temperature of different liquids and gases as well as the surface temperature of solid objects in the range of -200 ℃ ~ 500 ℃. It adopts the specialized temperature module, with the linearity corrected temperature sensing element, supports the... [See More]
- Reference Resistance: 100 Ohms; 1000 Ohms
- Reference Material: Platinum
from KOBOLD Instruments, Inc.
Product Features. High Accuracy. 4-20 mA Loop Powered. Rugged, All 316 SS Construction. -200 to 600 °C Temperature Range. Custom Designs Available. Accessible Zero & Span. KOBOLD TMA temperature sensor employs a Pt100 class B resistive temperature detector (RTD) combined with an integrated loop... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 1112
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from OMEGA Engineering, Inc.
The PRTXB and PRTXAL series are 2-wire transmitters that provide 4 to 20 mA signal representing temperature linearized. The front keypad is used for power on/off, min/max functions, selection of deg F, C or K, auto shutoff times (for battery models), calibration and configuration options. [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -72.4 to 738
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from NOSHOK, Inc.
The NOSHOK 850 Temperature Switch measures and displays temperature and has one or two switching outputs as well as an optional analog output. The temperature set points, reset points, switching functions and the measuring range of the optional analog output are simple to adjust via two buttons. All... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -300 to 1100
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from Ultra Energy
7600D Temp Transmitter, Industrial Temperature Transmitter, DIN Rail Mount, RTD, T/C, Ω, mV [See More]
- Reference Resistance: 100 Ohms; 500 Ohms; 1000 Ohms
- Sensed Temperature: -328 to 1562
- Reference Material: Platinum; Nickel/Nickel Alloys
- Mounting Options: DIN Rail Mounting
from R. STAHL, Inc.
One unit for nearly all temperature sensors indivdually configurable. Signal duplication possible. Galvanic isolation between input, output, power supply and configuration interface. Open-circuit and short-circuit monitoring and messaging (can be switched off). Simple configuration with PC or... [See More]
- Reference Resistance: 100 Ohms; 500 Ohms; 1000 Ohms; ThermoCouple L, U, XK
- Sensed Temperature: -328 to 3213
- Reference Material: Platinum; Nickel/Nickel Alloys
- Mounting Options: DIN Rail Mounting
from Sitron
The robust and compact Pt10 Temperature Sensor has a Pt100 RTD platinum sensor inserted into the sheath with optimum accuracy and stability. The platinum RTD has the function of converting the measured temperature in the process to resistance in a proportional way with precision. As it does not have... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -148 to 392
- Reference Material: Platinum
- Output: Other Output Option
from Status Instruments, Inc.
PUSH BUTTON IN HEAD TEMPERATURE TRANSMITTERS. SIMPLE PUSH BUTTON CONFIGURATION. HIGH STABILITY. INPUT/OUTPUT ISOLATION. 4 TO 20 mA TWO WIRE OUTPUT. PROGRAMMABLE BURNOUT. USER PUSH BUTTON TRIM. 10 YEAR WARRANTY [See More]
- Reference Resistance: 100 Ohms; 120 Ohms; 500 Ohms (optional feature); 1000 Ohms (optional feature)
- Sensed Temperature: -328 to 3200
- Reference Material: Platinum; Nickel/Nickel Alloys
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from PR electronics
Application. Linearized temperature measurement with Pt100...Pt1000, Ni100...Ni1000, or TC sensor. Difference or average temperature measurement of 2 resistance or TC sensors. Conversion of linear resistance variation to a standard analog current signal, for instance from valves or Ohmic level... [See More]
- Reference Resistance: 100 Ohms
- Output: Analog Current (Typical 4-20 mA)
- Reference Material: Platinum; Nickel/Nickel Alloys
- Supply Voltage: 8.0...30 VDC
from Acromag, Inc.
100 ohm Pt RTD or 0-900 ohm input. 4-20mA output (sink/source). 12-32V DC loop/local power. USB configuration. The TT231 model is a space-saving two-wire transmitter that converts a 100 ohm Platinum RTD sensor input to a proportional 4-20mA signal. Power is received from the output loop current or a... [See More]
- Reference Resistance: 100 Ohms
- Other Input: Accepts Generic Resistance Inputs
- Reference Material: Platinum
- Mounting Options: DIN Rail Mounting
from Automation24, Inc.
The Pt100 temperature sensor iTHERM TM101-AABAA4GC1A2A1 from Endress+Hauser offers reliable temperature measurement with fundamental sensor technology and a fixed, non-interchangeable insert. The temperature sensor with a measurement range of -58 to 392 °F comes with a terminal block electrical... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -58 to 392
- Reference Material: Platinum
- Supply Voltage: 1/2" NPT Male
from KOBOLD Instruments, Inc.
Product Features. No Features Available [See More]
- Reference Resistance: 100 Ohms
- Output: Analog Current (Typical 4-20 mA)
- Reference Material: Platinum
from OMEGA Engineering, Inc.
The TXDIN101 is a computerized, PC programmable, galvanically isolated two-wire smart transmitter. The unit converts 13 types of thermocouple sensors; 12 types of RTD sensors, configured as 2-, 3- and 4-wires; potentiometer, resistor and millivolt inputs, single or differential into process current... [See More]
- Reference Resistance: 100 Ohms
- Other Input: Accepts Generic Analog Voltage Inputs; Accepts Generic Resistance Inputs
- Reference Material: Platinum
- Sensed Temperature: -328 to 4208
from NOSHOK, Inc.
Large 4-digit LED display, Field re-programmable with optional PC interface module and software, Security temper protection for re-programming, 4 mA to 20 mA, programmable linearized signal output, Utilizes self-calibration feature for accurate and stable performance, Optional fully programmable... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -325 to 1100
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from Ultra Energy
7600H Temp Transmitter, Industrial Temperature Transmitter, Head Mount, RTD, T/C, Ω, mV [See More]
- Reference Resistance: 100 Ohms; 500 Ohms; 1000 Ohms
- Sensed Temperature: -328 to 1562
- Reference Material: Platinum; Nickel/Nickel Alloys
- Output: Analog Current (Typical 4-20 mA)
from Sitron
The Pt10 Temperature Sensor with small Nylon (N1) head has a Pt100 RTD platinum sensor with great precision and stability inserted into the sheath. The platinum RTD has the function of converting the temperature measured in the process into resistance in a proportional way with precision. As it does... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -148 to 392
- Reference Material: Platinum
- Output: Other Output Option
from Status Instruments, Inc.
INTRODUCTION. The SEM1605P is the next generation DIN rail mounted temperature transmitter from Status Instruments. It has been designed to accept most common RTD temperature sensor inputs and provide the user with a standard two-wire 4 to 20mA output signal. All temperature ranges are linear to... [See More]
- Reference Resistance: 100 Ohms; 120 Ohms
- Sensed Temperature: -328 to 1562
- Reference Material: Platinum; Nickel/Nickel Alloys; Copper
- Mounting Options: DIN Rail Mounting
from PR electronics
Application. Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100. HART ® communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors. Conversion of linear resistance to a standard... [See More]
- Reference Resistance: 100 Ohms; 120 Ohms; 200 Ohms; 500 Ohms; 1000 Ohms
- Mounting Options: DIN Rail Mounting
- Reference Material: Platinum; Nickel/Nickel Alloys
- Output: Analog Current (Typical 4-20 mA)
from Acromag, Inc.
DT330 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT335 model is a four-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to proportional control signals. Each channel supports DC current or voltage output. [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 120 Ohms; 200 Ohms; 400 Ohms; 500 Ohms; 1000 Ohms; 0-4500 ohm
- Mounting Options: DIN Rail Mounting
- Reference Material: Platinum; Nickel/Nickel Alloys; Copper
- Output: Analog Current (Typical 4-20 mA)
from Automation24, Inc.
The Pt100 temperature sensor iTHERM TM101-AABAA6GC1A2A1 from Endress+Hauser offers reliable temperature measurement with fundamental sensor technology and a fixed, non-interchangeable insert. The temperature sensor with a measurement range of -58 to 392 °F comes with a terminal block electrical... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -58 to 392
- Reference Material: Platinum
- Supply Voltage: 1/2" NPT Male
from OMEGA Engineering, Inc.
It provides 2 channels of configurable inputs, and supports multiple voltage, RTD, thermocouple inputs with auto reference junction compensation. If parallel connected to an external precise resistance, it accepts current signal input. Each channel has its own digital filtering and can adjust its... [See More]
- Reference Resistance: 100 Ohms; 50 Ohm
- Sensed Temperature: -328 to 4172
- Reference Material: Platinum; Copper
- Mounting Options: DIN Rail Mounting
from NOSHOK, Inc.
High accuracy (±0.1%), 2-wire loop-powered 4 mA to 20 mA output, Linearized output to temperature, Input RTD PT100 with 3-wire compensation, Analog design, potentiometer adjustable, Factory calibrated for fixed range, Metal housing, Fits standard heads, Optional model is fully field re-programmable... [See More]
- Reference Resistance: 100 Ohms
- Output: Analog Current (Typical 4-20 mA); Analog Voltage (e.g. 1-5 Vdc) (optional feature)
- Reference Material: Platinum
- Sensor Connection: Terminal Block
from Ultra Energy
9100D Temp Transmitter, Industrial Temperature Transmitter, DIN Rail Mount, RTD, T/C, Ω, mV, HART [See More]
- Reference Resistance: 100 Ohms; 500 Ohms; 1000 Ohms
- Sensed Temperature: -328 to 1562
- Reference Material: Platinum; Nickel/Nickel Alloys
- Mounting Options: DIN Rail Mounting
from Sitron
The robust STD-T Temperature Transmitter in 316 Stainless Steel. The 90 ° mounted display facilitates the process visualization, besides being rotated in 330 ° both the display and the body, making the transmitter very flexible in any installed position. With a 5-digit multifunction LCD... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -148 to 392
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Status Instruments, Inc.
The SEM210 is a second generation ‘Smart ’ in head temperature transmitter that accepts any commonly used temperature sensor, Slidewire transducer or Millivolt signal and converts the output to the industry standard 4-20 mA transmission signal. The sensor type and range are easily... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 3200
- Reference Material: Platinum
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from PR electronics
Application. Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100. HART ® communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors. Conversion of linear resistance to a standard... [See More]
- Reference Resistance: 100 Ohms; 120 Ohms; 200 Ohms; 500 Ohms; 1000 Ohms
- Mounting Options: DIN Rail Mounting
- Reference Material: Platinum; Nickel/Nickel Alloys
- Output: Analog Current (Typical 4-20 mA)
from Acromag, Inc.
DT230 series signal conditioners provide two independent I/O channels in a single, space-saving unit. The DT235 model is a two-wire dual transmitter that isolates and converts RTD or linear resistance sensor inputs to a proportional 4-20mA control signal. Power is received from the output loop... [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 120 Ohms; 200 Ohms; 400 Ohms; 500 Ohms; 1000 Ohms; 0-4500 ohm
- Mounting Options: DIN Rail Mounting
- Reference Material: Platinum; Nickel/Nickel Alloys; Copper
- Output: Analog Current (Typical 4-20 mA)
from Automation24, Inc.
The Pt100 temperature sensor iTHERM TM101-AABAA8GC1A2A1 from Endress+Hauser offers reliable temperature measurement with fundamental sensor technology and a fixed, non-interchangeable insert. The temperature sensor with a measurement range of -58 to 392 °F comes with a terminal block electrical... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -58 to 392
- Reference Material: Platinum
- Supply Voltage: 1/2" NPT Male
from OMEGA Engineering, Inc.
TX900 Series transmitters feature dip switch selection of input type and range. The following models are available: TX901 (non-isolated, accepts J, K,T, E, R or S thermocouples); TX903 (isolated, accepts J, K, T, E, R or S thermocouples; TX904 (non-isolated, accepts 100 ohm Pt RTD's 2- or 3- wire);... [See More]
- Reference Resistance: 100 Ohms
- Other Input: Accepts Generic Analog Voltage Inputs
- Reference Material: Platinum
- Sensed Temperature: 149 to 3193
from Ultra Energy
9100H Temp Transmitter, Industrial Temperature Transmitter, Head Mount, RTD, T/C, Ω, mV, HART [See More]
- Reference Resistance: 100 Ohms; 500 Ohms; 1000 Ohms
- Sensed Temperature: -328 to 1562
- Reference Material: Platinum; Nickel/Nickel Alloys
- Output: Analog Current (Typical 4-20 mA)
from Sitron
The robust STD-T Temperature Transmitter with Aluminum head, provides 4 … 20mA (2-wire) analog current signal with HART communication protocol, making it easy to integrate the instrument into industrial networks. The head-mounted display makes it easy to see the process, as well as being... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -148 to 392
- Reference Material: Platinum
- Output: Analog Current (Typical 4-20 mA)
from Status Instruments, Inc.
INTRODUCTION. The TTR200 & TTC200 are cost effective “smart ” in head temperature transmitters that accept RTD/Slide Wire or Thermocouple/mV inputs and converts them to a standard loop powered industrial 4 to 20mA transmission signal over a userprogrammed range. Two versions are... [See More]
- Reference Resistance: 100 Ohms; 120 Ohms; 200 Ohms; 400 Ohms; 500 Ohms; 1000 Ohms; 53, 507.5, 604 Ohm
- Sensed Temperature: -328 to 1532
- Reference Material: Platinum; Nickel/Nickel Alloys; Copper
- Mounting Options: Thermohead or Thermowell Mounting (e.g. "Hockey puck" Style)
from PR electronics
Advanced features. The 5131A transmitter can be configured with the software program PReset using a standard PC and the Loop Link communications unit. Application. Independent channel jumper selectable inputs for current/voltage or temperature. Current input programmable in range 0...100 mA and... [See More]
- Reference Resistance: 100 Ohms
- Mounting Options: DIN Rail Mounting
- Reference Material: Platinum; Nickel/Nickel Alloys
- Output: Analog Current (Typical 4-20 mA)
from Acromag, Inc.
100 ohm Pt, 120 ohm Ni, 10 ohm Cu (selectable type) input. 4 to 20mA DC output. 12-50V DC from output loop power. DIP-switch configuration, push-button calibration. These units accept universal RTD or resistance input signals and output proportional DC current signals. The output can also be... [See More]
- Reference Resistance: 10 Ohms; 100 Ohms; 120 Ohms
- Other Input: Accepts Generic Resistance Inputs
- Reference Material: Platinum; Nickel/Nickel Alloys; Copper
- Sensed Temperature: -328 to 1562
from Automation24, Inc.
The Pt100 temperature sensor iTHERM TM101-AABAB2GC1A2A1 from Endress+Hauser offers reliable temperature measurement with fundamental sensor technology and a fixed, non-interchangeable insert. The temperature sensor with a measurement range of -58 to 392 °F comes with a terminal block electrical... [See More]
- Reference Resistance: 100 Ohms
- Sensed Temperature: -58 to 392
- Reference Material: Platinum
- Supply Voltage: 1/2" NPT Male