Ungrounded Thermocouple Thermocouple Temperature Probes
from Pyromation
Explosion-Proof, Fixed-Element Thermocouples are made for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device, eliminating the potential for ignition of flammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependent on... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element
- Base, Noble and Refractory Metal Type: E (optional feature); J (optional feature); K (optional feature); T (optional feature)
- Probe Configuration: Straight Probe
from DigiKey
QUICK DISCONNECT THERMOCOUPLE PR [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 968
- Base, Noble and Refractory Metal Type: J; K
- Probe Configuration: Surface; Other (Special Purpose); Immersion / Penetration, Pointed
from Conax Technologies
These type K ungrounded thermocouples are manufactured using Special (+/-0.4%) limits and have a time response of 1.7 to 4.0 seconds depending on the tip configuration. Conax Technologies manufactures these exhaust thermocouples with tip diameters from .062 diameter to .125. They are used on all... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: K
- Probe Features: Available as an Assembly
from Tempco Electric Heater Corporation
Forms easily to any angle. One style can replace several fixed length thermocouples. Use with bayonet adapters. Style 1 – Spring Adjustable Bayonet Thermocouple. Insertion length adjustable from 1" to 10". Style 2 – Armor Cable Adjustable Bayonet Thermocouple. Insertion length adjustable... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T
- Process Connection: Bayonet
from Pyromation
Explosion-proof (XP) thermocouples and RTDs are designed for use in hazardous locations in refineries, storage facilities and gas processing plants. These sensors are built to extinguish flames inside the device, eliminating the potential for ignition of flammable mixtures in the surrounding... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element; Double Element; More Than Two Elements
- Base, Noble and Refractory Metal Type: E; J; K; T
- Probe Configuration: Straight Probe
from DigiKey
QUICK DISCONNECT THERMOCOUPLE AS [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 968
- Base, Noble and Refractory Metal Type: J
- Probe Configuration: Surface; Other (Special Purpose); Immersion / Penetration, Pointed
from Conax Technologies
These type K ungrounded thermocouples are manufactured using Special (+/-0.4%) limits and have a time response of 1.7 to 4.0 seconds depending on the tip configuration. Conax Technologies manufactures these exhaust thermocouples with tip diameters from .062 diameter to .125. They are used on all... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: K
- Diameter or Width Range: 0.0620 to 0.1250
from Tempco Electric Heater Corporation
Style 6 —Rigid Straight Compression Fitting Thermocouple Style 7 —Rigid 45 ° Bend Compression Fitting Thermocouple Style 8 —Rigid 90 ° Bend Compression Fitting Thermocouple [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Element Configuration: Single Element; Double Element
- Base, Noble and Refractory Metal Type: E; J; K; N; T
- Probe Configuration: Straight Probe; Angled Probe
from Pyromation
Pyromation ’s high-temperature thermocouples are designed to operate in a temperature range of (982 to 1871) ºC [1800 to 3400] ºF. They are designed for use in vacuum furnaces and other applications requiring high-temperature measurement in controlled atmospheric conditions. Metal... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element; Double Element (optional feature)
- Base, Noble and Refractory Metal Type: B (optional feature); S (optional feature); R (optional feature); C (optional feature)
- Sensed Temperature: 982 to 1149
from DigiKey
QUICK DISCONNECT THERMOCOUPLE PR [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1472
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Surface; Other (Special Purpose); Immersion / Penetration, Pointed
from Conax Technologies
Conax Technologies has introduced a solution that offers significant cost savings for LM2500 and LM5000 exhaust gas temperature measurement applications. Conax has a proven history of manufacturing reliable temperature sensors for large frame gas turbines and aeroderivative engines and now offers a... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -20 to 800
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Penetration (Needle) Probe
from Tempco Electric Heater Corporation
Style A —Adjustable Tip. Eliminates excess inventory. Tip can be field adjusted from flush to 2 inches. MgO insulated. Can be installed wherever standard melt thermocouples are in use. Bolt with Teflon ® insert at tip has a maximum operating temperature of 500 °F (260 °C); without... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Probe Configuration: Straight Probe; Flexible Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T
- Sensor Termination Type: Plug or Quick Connect
from Pyromation
Miniature thermocouple assemblies have very small swaged sheath diameters containing standard purity MgO (96%) insulated thermocouple elements. The small sheath size provides accurate and fast response time temperature measurement in a variety of laboratory, process, and special applications. These... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element
- Base, Noble and Refractory Metal Type: J (optional feature); K (optional feature)
- Probe Configuration: Straight Probe
from DigiKey
QUICK DISCONNECT THERMOCOUPLE AS [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1652
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Air Probe; Surface; Other (Special Purpose); Air, Beaded
from Conax Technologies
Conax Technologies has introduced a cost-effective solution for LM6000 exhaust gas temperature measurement applications. Conax has a proven history of manufacturing reliable temperature sensors for large frame gas turbines and aeroderivative engines and now offers an aftermarket equivalent for LM... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -20 to 800
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Penetration (Needle) Probe
from Tempco Electric Heater Corporation
Style MTA1 MI Cable TC Assembly. Transition to Lead Wire [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T; B; S; R
from Pyromation
The assemblies listed below are designed for a broad range of applications that require resistance to corrosion and chemical attack. They provide very good temperature measurement and service life in plating, pickeling, and acid bath applications. The stainless steel sheath is coated with FEP Teflon... [See More]
- Configuration: Grounded Thermocouple (optional feature); Ungrounded Thermocouple
- Element Configuration: Single Element
- Base, Noble and Refractory Metal Type: J
- Probe Configuration: Straight Probe
from DigiKey
THERMOCOUPLE WITH SELF-ADHESIVE [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 599
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Air Probe; Surface; Other (Special Purpose); Air, Beaded
from Conax Technologies
These type K ungrounded thermocouples are manufactured using Special (+/-0.4%) limits and have a time response of 1.7 to 4.0 seconds depending on the tip configuration. Conax Technologies manufactures these exhaust thermocouples with tip diameters from .062 diameter to .125. They are used on all... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: K
- Probe Features: Available as an Assembly
from Tempco Electric Heater Corporation
Style MTA2 MI Cable TC Assembly. Plug or Jack Termination [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T; B; S; R
- Sensor Termination Type: Plug or Quick Connect
from Pyromation
Explosion-Proof, Spring-Loaded Thermocouples are made for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device, eliminating the potential for ignition of flammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependent on... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element
- Base, Noble and Refractory Metal Type: E (optional feature); J (optional feature); K (optional feature); T (optional feature)
- Probe Configuration: Straight Probe
from DigiKey
THERMOCOUPLE WITH SELF-ADHESIVE [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 23 to 392
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Air Probe; Surface; Other (Special Purpose); Air, Beaded
from Conax Technologies
These type K ungrounded thermocouples are manufactured using Special (+/-0.4%) limits and have a time response of 1.7 to 4.0 seconds depending on the tip configuration. Conax Technologies manufactures these exhaust thermocouples with tip diameters from .062 diameter to .125. They are used on all... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: K
- Probe Features: Available as an Assembly
from Tempco Electric Heater Corporation
Style MTA3 MI Cable TC Assembly. Open Disc Termination [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T; B; S; R
from DigiKey
THERMOCOUPLE WITH SELF-ADHESIVE [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 1 to 500
- Base, Noble and Refractory Metal Type: J
- Probe Configuration: Air Probe; Surface; Other (Special Purpose); Air, Beaded
from Conax Technologies
The environmental conditions found in pharmaceutical autoclave chambers are extreme for any equipment. These conditions are a major cause of sensor failure in chamber/load probes due to the ingress of moisture into the sensor and the unacceptable leakage of steam/condensate through the bulkhead... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Element Configuration: Single Element; Double Element
- Base, Noble and Refractory Metal Type: E; J; K; T
- Sensed Temperature: -58 to 302
from Tempco Electric Heater Corporation
Style MTA4 MI Cable TC Assembly. Stripped Cold End [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: J; K
- Sensor Termination Type: Bare or Insulated Lead Wires
from DigiKey
THERMOCOUPLE WITH SELF-ADHESIVE [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 1 to 500
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Air Probe; Surface; Other (Special Purpose); Air, Beaded
from Conax Technologies
Sterisensor ® withstands the environmental conditions found in pharmaceutical autoclave chambers. Sterisensor ’s engineered moisture seal prevents the ingress of moisture which is the leading cause of failure. Thermocouple Type T or RTD, 100 ohms @0 °C, .00385 ohms/ohms/ °C... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element; Double Element
- Base, Noble and Refractory Metal Type: T
- Sensed Temperature: -58 to 302
from Tempco Electric Heater Corporation
Style MTA5 MI Cable TC Assembly. Connection Head [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T; B; S; R
- Process Connection: Threaded (NPT) Fitting
from Conax Technologies
Standard polarized plug and jack termination for use with all calibration types. Plug and jack assemblies are made from molded glass filled thermoset compounds and are designed to operate in temperatures to 300 ° F (150 ° C). Polarity identification marks are molded in the bodies for... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: B (optional feature); S (optional feature); R (optional feature); C (optional feature)
- Diameter or Width Range: 0.1250 to 0.3750
from Tempco Electric Heater Corporation
Style MTA6 MI Cable TC Assembly. Connection Head with 1/2" NPT Hex Nipple [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: J; K
- Process Connection: Threaded (NPT) Fitting
from Conax Technologies
This exclusive Conax Technologies design provides a practically unbreakable connection between the leadwire and probe lead. The T3 epoxy-filled transition is supplied with Teflon-insulated extension wire as standard; silicone-impregnated fiberglass insulation is also available. Standard extension... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: B (optional feature); S (optional feature); R (optional feature); C (optional feature)
- Diameter or Width Range: 0.1250 to 0.3750
from Tempco Electric Heater Corporation
Style MTA7 MI Cable TC Assembly. Connection Head with 1/2"NPT Pipe Nipple [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T; B; S; R
- Process Connection: Threaded (NPT) Fitting
from Conax Technologies
Conax Technologies provides high temperature assemblies with T5, T8 and T11 termination heads in aluminum, stainless steel or cast iron to meet application needs. T5 termination heads meet NEMA 4 requirements providing protection against windblown dust and rain, splashing water, hose-directed water... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: B (optional feature); S (optional feature); R (optional feature); C (optional feature)
- Diameter or Width Range: 0.1250 to 0.3750
from Tempco Electric Heater Corporation
Style MTA8 MI Cable TC Assembly. Connection Head with 1/2" NPT Nipple, Union, Nipple [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T; B; S; R
- Process Connection: Threaded (NPT) Fitting
from Conax Technologies
Conax Technologies provides high temperature assemblies with T5, T8 and T11 termination heads in aluminum, stainless steel or cast iron to meet application needs. T5 termination heads meet NEMA 4 requirements providing protection against windblown dust and rain, splashing water, hose-directed water... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: B (optional feature); S (optional feature); R (optional feature); C (optional feature)
- Diameter or Width Range: 0.1250 to 0.3750
from Tempco Electric Heater Corporation
Style MTA9 MI Cable TC Assembly. Handheld Probe [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T
- Process Connection: None or Hand held
from Conax Technologies
Conax Technologies provides high temperature assemblies with T5, T8 and T11 termination heads in aluminum, stainless steel or cast iron to meet application needs. T5 termination heads meet NEMA 4 requirements providing protection against windblown dust and rain, splashing water, hose-directed water... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: B (optional feature); S (optional feature); R (optional feature); C (optional feature)
- Diameter or Width Range: 0.1250 to 0.3750
from Tempco Electric Heater Corporation
These sensors are made-to-order to meet the requirements of the specific application. The styles depicted below are the most common constructions. Consult Tempco for other sizes and construction methods. [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T
from Conax Technologies
Thermocouples for ASM Epsilon ® Reactors. Highest Quality We manufacture our sensors using the best available materials, cleanest assembly cell and the finest workmanship in the industry. Best Available Materials. Pt and Pt/Rh wires are manufactured from mined ores – never manufactured... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Diameter or Width Range: 0.0200 to 0.0590
- Probe Configuration: Curved Probe
- Sheath Material: Quartz
from Tempco Electric Heater Corporation
Direct Replacement Thermocouples. Manufactured with the highest quality materials and workmanship. Thermocouple wire is stranded (for flexibility) ANSI Type J thermocouple grade, with ANSI color-coded fiberglass insulation (White=Positive, Red=Negative). All hot junctions are grounded. Spade lugs... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Probe Configuration: Straight Probe; Flexible Probe; Angled Probe
- Base, Noble and Refractory Metal Type: J
- Sensor Termination Type: Bare or Insulated Lead Wires (optional feature); Plug or Quick Connect (optional feature)
from Tempco Electric Heater Corporation
Style TTW Tube & Wire Thermocouples [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Probe Configuration: Straight Probe; Angled Probe
- Base, Noble and Refractory Metal Type: E; J; K; N; T
- Sensor Termination Type: Bare or Insulated Lead Wires
from Chromalox
Heat Trace or Pipe Sensing Applications. 316 Stainless Steel Sheath. Moisture Resistant Heads. 3/4" or 1/2" NPT Threaded Extension Wire Opening. 4" to 8" Cold Leg Standard for Varying Insulation Depths. 100 ohm RTD, ± 0.12% Accuracy. Fiberglass Insulated RTD Probe. RTD or Universal... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -300 to 1800
- Base, Noble and Refractory Metal Type: E; J; K; T
- Probe Configuration: Curved Probe
from OMEGA Engineering, Inc.
These thermocouple probes provide a quick and convenient method for measuring temperature in your process. They can be used as-is, mounted into your process using one of Omega's line of Compression Fittings, or used in a thermowell by using one of our Spring Loaded Fittings. The M12 Series... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element; Double Element (optional feature)
- Base, Noble and Refractory Metal Type: J; K
- Sensed Temperature: -58 to 194
from Minco
Minco electrically isolated thermocouple probes feature an electrically isolated sensing tip, enabling temperature sensing in electrically charged applications. They also feature a sensing tip constructed of copper alloy. The copper tip is twenty times more conductive than stainless steel, providing... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Electrically Isolated Thermocouples
- Sensed Temperature: -58 to 500
- Diameter or Width Range: 0.1880
from Nanmac Corporation
These thermocouples are available with either stainless steel or inconel sheaths. Fitted with a transition from the sheath to 36 inches of fiberglass insulated flexible leads which are enclosed within stainless steel armor for use in rugged applications. These units are available in thermocouple... [See More]
- Configuration: Grounded Thermocouple (optional feature); Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Flexible Probe
- Base, Noble and Refractory Metal Type: E; J; K; T
- Diameter or Width Range: 0.0620 to 0.2500
from GP:50 Melt Pressure
Universal Thermocouples for extrusion and injection molding applications provide an economical and reliable choice for temperature measurements within the plastics industry. Models are available in either J-type of K-type with stainless steel flexible housing, incorporating open leads or industry... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Sensed Temperature: 0.0 to 900
- Base, Noble and Refractory Metal Type: J; K
- Probe Configuration: Flexible Probe
from Cole-Parmer
bull; Flexible Insulated Thermocouple Probes with Stripped Wire Leads for a Wide Range of Temperature Monitoring. • Response Time: 1 seconds or greater. • All insulated-wire probes include straight insulated cable with no handle and stripped leads. • Custom designs or changes to this... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 221
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 120
from CHINO Works America Inc.
The NC series solidpak thermocouples are the high performance thermocouples that feature high sensitivity, solidity, and durability required in a general industrial sensor. The gap between a protective tube and a thermocouple wire is densely filled with magnesium oxide. The thick protective tube... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Double Element
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Straight Probe; Penetration (Needle) Probe
from Acrolab Ltd.
Explosion Proof Fixed Element Thermocouples are for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device eliminating the potential for ignition of flammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependant on connection... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K; T
- Diameter or Width Range: 0.1250 to 0.3750
from Ultra Energy
General Purpose Thermocouple, Industrial Temperature Sensor, Thermocouple. Designed for a wide range of applications where a simple mounting scheme is needed. Model 101 is a straight sheath temperature sensor. Model 103 is a Reduced Tip/Fast Response temperature sensor. [See More]
- Configuration: Grounded Thermocouple (optional feature); Ungrounded Thermocouple; Exposed Thermocouple (optional feature)
- Sensed Temperature: -328 to 2300
- Base, Noble and Refractory Metal Type: E (optional feature); J (optional feature); K; N (optional feature); T (optional feature)
- Probe Configuration: Straight Probe
from Chromalox
Type J, K, and T Thermocouples. - Grounded. - Ungrounded. Sheath Materials. - 304 Stainless Steel. - 316 Stainless Steel. Junction Fittings. - Crimped. - Single Slot Spring Loaded. - Bayonet Fitting. Termination Options: &nbps; &nbps; &nbps;- T/C Wire with Stripped Leads;. &nbps;... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Sensed Temperature: -328 to 1600
- Base, Noble and Refractory Metal Type: J; K; T
- Probe Configuration: Flexible Probe
from OMEGA Engineering, Inc.
These high pressure thermocouple plug sensors are ideal for vessel applications, pressurized containers and applications requiring mounted NPT security. The 304SS sheath has a 6.4mm (1/4") dia. that extends 1/2" from the end of the 1/4 or 1/8NPT pipe plug. Other length sheaths are available. The... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Element Configuration: Single Element (optional feature); Double Element (optional feature)
- Base, Noble and Refractory Metal Type: E; J; K; T
- Sensed Temperature: ? to 1202
from Minco
Minco embedment thermocouples are physically interchangeable with Minco embedment RTDs and feature four tin plated copper alloy case styles to meet a variety of installation options, including: spring loading or potting in drilled holes and a factory applied babbitt metal tip to reduce overheating... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Embedment Thermocouples
- Sensed Temperature: -299 to 392
- Diameter or Width Range: 0.2750
from Nanmac Corporation
The construction of this thermocouple is a one piece design which does not utilize any transition fitting. Advantages of this construction are no splices from thermocouple to lead wire and no transition adaptors having a diameter greater than the thermocouple sheath. Units can therefore be mounted... [See More]
- Configuration: Grounded Thermocouple (optional feature); Ungrounded Thermocouple; Exposed Thermocouple
- Probe Configuration: Flexible Probe
- Base, Noble and Refractory Metal Type: E; J; K; T
- Diameter or Width Range: 0.0620 to 0.2500
from Cole-Parmer
bull; Flexible Insulated Thermocouple Probes with Stripped Wire Leads for a Wide Range of Temperature Monitoring. • Response Time: 1 seconds or greater. • All insulated-wire probes include straight insulated cable with no handle and stripped leads. • Custom designs or changes to this... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -250 to 221
- Base, Noble and Refractory Metal Type: K
- Sensitive Length: 120
from Acrolab Ltd.
Explosion Proof Spring-Loaded Thermocouples are for use in U.S. and Canadian hazardous areas. They are designed to extinguish flames inside the device eliminating the potential for ignition of flammable mixtures in the surrounding atmosphere. FM and CSA approved assemblies, dependant on connection... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: E; J; K
- Diameter or Width Range: 0.1250 to 0.3750
from Ultra Energy
Spring Loaded TC, Industrial Temperature Sensor, Thermocouple. Designed for applications where a spring-loaded threaded male fitting is required for mounting. [See More]
- Configuration: Grounded Thermocouple (optional feature); Ungrounded Thermocouple; Exposed Thermocouple (optional feature)
- Sensed Temperature: -328 to 2300
- Base, Noble and Refractory Metal Type: E (optional feature); J (optional feature); K; N (optional feature)
- Probe Configuration: Straight Probe
from Chromalox
Industrial thermocouples are provided in a variety of styles and materials to meet rugged industrial applications. A wide selection of sensor types, connection heads, leadwire termination options and accessories are available. Type J, K, T and E Thermocouples. - Grounded. - Ungrounded. - Exposed. [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple; Exposed Thermocouple
- Element Configuration: Single Element; Double Element
- Base, Noble and Refractory Metal Type: E; J; K
- Sensed Temperature: -328 to 1600
from OMEGA Engineering, Inc.
The OMEGA ® TCS-S-CB and TCS-H-CB Series Thermocouple Sensors are designed for use in Sanitary or Hygienic Clean-in-Place applications in the Food, Dairy, Beverage and BioPharmaceutical industries. These sensors are manufactured with 316L stainless steel housings that meet the dimensional... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element
- Base, Noble and Refractory Metal Type: E (optional feature); J (optional feature); K (optional feature); T (optional feature)
- Sensed Temperature: -58 to 392
from Minco
Minco embedment thermocouples are physically interchangeable with Minco embedment RTDs and feature four tin plated copper alloy case styles to meet a variety of installation options, including: spring loading or potting in drilled holes and a factory applied babbitt metal tip to reduce overheating... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Embedment Thermocouples
- Sensed Temperature: -299 to 392
- Diameter or Width Range: 0.2750
from Nanmac Corporation
Probes can be supplied spring loaded or with fixed mounted fittings. All fittings are 304 stainless steel with 1/2 inch NPT for mounting into: walls, connector heads, or thermowells. The (SL - spring loaded) units allow up to 3/4 inch of travel. The (W - welded) units have the 1/2 inch NPT fitting... [See More]
- Configuration: Grounded Thermocouple (optional feature); Ungrounded Thermocouple; Exposed Thermocouple
- Diameter or Width Range: 0.0620 to 0.2500
- Base, Noble and Refractory Metal Type: E; J; K; T
from Cole-Parmer
bull; Flexible Insulated Thermocouple Probes with Stripped Wire Leads for a Wide Range of Temperature Monitoring. • Response Time: 1 seconds or greater. • All insulated-wire probes include straight insulated cable with no handle and stripped leads. • Custom designs or changes to this... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -328 to 221
- Base, Noble and Refractory Metal Type: T
- Sensitive Length: 120
from Acrolab Ltd.
Acrolab Ltd is a thermal engineering solutions company and this year marks our 70th year as a custom solutions provider for various industrial manufacturers from high-end consumer and defense electronics to plastics, rubber, and composite processors in all areas of manufacturing. Acrolab ’s... [See More]
- Configuration: Grounded Thermocouple; Ungrounded Thermocouple
- Probe Configuration: Straight Probe
- Base, Noble and Refractory Metal Type: J; K; T
- Diameter or Width Range: 0.2500
from Ultra Energy
Welded Fitting TC, Industrial Temperature Sensor, RTD. Designed for direct immersion applications where a male fitting is needed for mounting. Model 201 is a straight sheath temperature sensor. Model 203 is a Reduced Tip/Fast Response temperature sensor. [See More]
- Configuration: Grounded Thermocouple (optional feature); Ungrounded Thermocouple; Exposed Thermocouple (optional feature)
- Sensed Temperature: -328 to 2300
- Base, Noble and Refractory Metal Type: E (optional feature); J (optional feature); K; N (optional feature); T (optional feature)
- Probe Configuration: Straight Probe
from OMEGA Engineering, Inc.
The 3-A Approved OMEGA ® TCS-S-NB9W and TCS-H-NB9W Series Thermocouple Sensors are designed for use in Sanitary or Hygienic Clean-in-Place applications in the Food, Dairy, Beverage and BioPharmaceutical industries. These sensors are manufactured with 316L stainless steel housings that meet the... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element
- Base, Noble and Refractory Metal Type: E (optional feature); J (optional feature); K (optional feature); T (optional feature)
- Sensed Temperature: -58 to 392
from Minco
Minco embedment thermocouples are physically interchangeable with Minco embedment RTDs and feature four tin plated copper alloy case styles to meet a variety of installation options, including: spring loading or potting in drilled holes and a factory applied babbitt metal tip to reduce overheating... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Embedment Thermocouples
- Sensed Temperature: -299 to 392
- Diameter or Width Range: 0.1880
from Cole-Parmer
bull; Designed for everyday needs - probe comes installed with a quick disconnect connector and a mating female connector. • Ideal for measuring liquids, gases, or semi solids. • Designed with ICONEL 600 sheath. • Response Time: 1.2 - 5 seconds or greater. • Includes a stand... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -250 to 1590
- Base, Noble and Refractory Metal Type: K
- Sensitive Length: 12
from OMEGA Engineering, Inc.
The M8M series thermocouples, with their small diameter probes and M8 connectors, can be used where other sensors can't. Thier smaller size allows for measurements in tight spaces, or when you need to have a minimum impact on the thermal environment that you are measuring. These thermocouple sensors... [See More]
- Configuration: Ungrounded Thermocouple
- Element Configuration: Single Element; Double Element (optional feature)
- Base, Noble and Refractory Metal Type: J; K
- Sensed Temperature: -58 to 194
from Minco
Minco embedment thermocouples are physically interchangeable with Minco embedment RTDs and feature four tin plated copper alloy case styles to meet a variety of installation options, including: spring loading or potting in drilled holes and a factory applied babbitt metal tip to reduce overheating... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Embedment Thermocouples
- Sensed Temperature: -299 to 392
- Diameter or Width Range: 0.1250
from Cole-Parmer
bull; Available in spring loaded and non-spring loaded styles. Thermocouple Probes are ideal for use in industrial applications, chemical processes, production lines, ovens, furnaces, and vessels. The probes conductor is made of 18 gauge wire and is encased with Magnesium Oxide insulation, and has... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 1330
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 6
from OMEGA Engineering, Inc.
Omega's new USB-TC Series of thermocouple probes with direct USB connection feature a rugged transition joint construction, 2 m (6') of shielded output cable and free user software that converts your PC into a temperature meter, chart recorder or data logger. Probes are available off-the-shelf in 18... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -328 to 1832
- Base, Noble and Refractory Metal Type: K
- Probe Configuration: Straight Probe
from Minco
Minco high temperature thermocouple probes feature a robust design that enables reliable operation in steam lines, exhaust gasses, and other high temperature applications. For applications requiring: High temperature operation. Temperature range of -100 to 550 °C (-148 to 1022 °F) [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); High Temperature Thermocouples
- Sensed Temperature: -148 to 1022
- Diameter or Width Range: 0.1880
from Cole-Parmer
bull; All-in-one, includes industrial probe head, element and thermowell. Thermocouple Probes Assemblies are ideal for use in industrial applications, chemical processes, production lines, ovens, furnaces, and vessels. The probes conductor is made of 20 gauge wire encased by ceramic insulators... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -32 to 1600
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from OMEGA Engineering, Inc.
OMEGA Exotic Thermocouple Probes are designed for use in extreme temperatures, up to 2315C (4200F). These probes utilize either Platinum/Rhodium (types R, S, or B) or Tungsten/Rhenium (types G, C, or D) elements, with a variety of insulations and sheath materials. Depending upon the sheath material... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: ? to 4172
- Element Configuration: Single Element
- Probe Configuration: Straight Probe
from Minco
Tip-sensitive, spring-loaded thermocouple temperature assemblies provide fast and accurate readings of bearings, blocks, frames and other surfaces. Minco ’s spring loaded holder ensures solid contact in drilled holes and has a built-in oil seal. The sensing probe features a copper alloy tip... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -58 to 500
- Base, Noble and Refractory Metal Type: E
- Probe Configuration: Other (Special Purpose); Tip Sensitive Thermocouples
from Cole-Parmer
bull; Hand held probes designed to be more compact and at a lower cost. • Each probe comes with a 3/16 â € diameter shaft, 36 â € long FEP extension cable and handle. • Available in grounded or ungrounded junctions. • Response Time: 2-4 seconds or greater. [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 425
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from OMEGA Engineering, Inc.
Omega's new Wireless Industrial Thermocouple and RTD Probe Assemblies feature a complete, ready to install, pre-wired sensor and wireless transmitter package. Each battery powered wireless unit will transmit measurement back to a host receiver up to 120 m (400') away. Each unit comes pre-programmed... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -328 to 3200
- Base, Noble and Refractory Metal Type: K (optional feature); N (optional feature); T (optional feature); S (optional feature); R (optional feature)
- Probe Configuration: Straight Probe
from Minco
Minco straight thermocouple probes feature a sensing tip constructed of copper alloy. The copper alloy tip is twenty times more conductive than stainless steel, providing increased sensitivity and rapid response to changes in temperature. The tip sensitive design also focuses the temperature... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Tip Sensitive Thermocouples
- Sensed Temperature: -299 to 500
- Diameter or Width Range: 0.1880
from Cole-Parmer
bull; Hollow Tube probes are designed to be more compactat and at a lower cost. • Response Time: 2-4 seconds or greater. • Each probe comes with a color coded ANSI mini connector: type J-black, type K-yellow, type T-blue, and type E-purple. • Custom designs or changes to this product... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 425
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from Minco
Minco straight thermocouple probes feature a sensing tip constructed of copper alloy. The copper alloy tip is twenty times more conductive than stainless steel, providing increased sensitivity and rapid response to changes in temperature. The tip sensitive design also focuses the temperature... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Tip Sensitive Thermocouples
- Sensed Temperature: -299 to 500
- Diameter or Width Range: 0.1880
from Cole-Parmer
bull; Hollow Tube probes are designed to be more compactat and at a lower cost. • Response Time: 2-4 seconds or greater. • Each probe comes with a color coded ANSI mini connector: type J-black, type K-yellow, type T-blue, and type E-purple. • Custom designs or changes to this product... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 425
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from Minco
Minco straight thermocouple probes feature a sensing tip constructed of copper alloy. The copper alloy tip is twenty times more conductive than stainless steel, providing increased sensitivity and rapid response to changes in temperature. The tip sensitive design also focuses the temperature... [See More]
- Configuration: Ungrounded Thermocouple
- Probe Configuration: Other (Special Purpose); Tip Sensitive Thermocouples
- Sensed Temperature: -299 to 500
- Diameter or Width Range: 0.1880
from Cole-Parmer
bull; PTFE-Insulated with Sealed Junction Used for Long-Term Immersion in Semi-Caustic Environments. • Each Probe is hermetically sealed and tested to 25psi. • Can be used for applications requiring an isolated junction. • Response Time: 0.75 seconds or greater. • All... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 400
- Base, Noble and Refractory Metal Type: J
from Cole-Parmer
bull; Designed to be an economical way to replace broken industrials probes. • The probes can be installed with current housing without having to purchase a whole new industrial assembly or can also to directly inserted. • Response Time: 3.75 seconds or greater. • Each probe comes... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1400
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from Cole-Parmer
bull; Designed to be an economical way to replace broken industrials probes. • The probes can be installed with current housing without having to purchase a whole new industrial assembly or can also to directly inserted. • Response Time: 3.75 seconds or greater. • Each probe comes... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1400
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 4
from Cole-Parmer
bull; Designed to be an economical way to replace broken industrials probes. • The probes can be installed with current housing without having to purchase a whole new industrial assembly or can also to directly inserted. • Response Time: 3.75 seconds or greater. • Each probe comes... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1400
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 6
from Cole-Parmer
bull; Each probe is 8 â € long and features a self-locking clip to ensure a sturdy hold onto the handle. • Ideal for switching out probes when working with multiple applications. • Response Time: 1.75-3 seconds or greater. • Each probe comes with a color coded ANSI mini... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1200
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 8
from Cole-Parmer
bull; Designed to be an economical way to replace broken industrials probes. • The probes can be installed with current housing without having to purchase a whole new industrial assembly. • Response Time: 3.75 seconds or greater. • Each probe comes with  ½ â €... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1400
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from Cole-Parmer
bull; Designed to be an economical way to replace broken industrials probes. • The probes can be installed with current housing without having to purchase a whole new industrial assembly. • Response Time: 3.75 seconds or greater. • Each probe comes with  ½ â €... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1400
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 4
from Cole-Parmer
bull; Designed to be an economical way to replace broken industrials probes. • The probes can be installed with current housing without having to purchase a whole new industrial assembly. • Response Time: 3.75 seconds or greater. • Each probe comes with  ½ â €... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1400
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 6
from Cole-Parmer
bull; Designed for reading two temperatures at one time. • Ideal for continuous monitoring. • Designed with 316 stainless steel sheath. • Response Time: 1.2 - 5 seconds or greater. • Includes a stand alone female connector for instalation to a thermocouple extension cable. [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1200
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from Cole-Parmer
bull; Designed for everyday needs - probe comes installed with a quick disconnect connector and a mating female connector. • Ideal for measuring liquids, gases, or semi solids. • Designed with 316 Stanless Steel sheath. • Response Time: 1.2 - 5 seconds or greater. • Includes a... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 825
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from Cole-Parmer
bull; Designed for everyday needs - probe comes installed with a quick disconnect connector and a mating female connector. • Ideal for measuring liquids, gases, or semi solids. • Designed with 316 Stanless Steel sheath. • Response Time: 1.2 - 5 seconds or greater. • Includes a... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: 32 to 1200
- Base, Noble and Refractory Metal Type: J
- Sensitive Length: 12
from Cole-Parmer
bull; Hand held probes designed to be more compact and at a lower cost. • Each probe comes with a 3/16 â € diameter shaft, 36 â € long FEP extension cable and handle. • Available in grounded or ungrounded junctions. • Response Time: 2-4 seconds or greater. [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -250 to 425
- Base, Noble and Refractory Metal Type: K
- Sensitive Length: 12
from Cole-Parmer
bull; Hollow Tube probes are designed to be more compactat and at a lower cost. • Response Time: 2-4 seconds or greater. • Each probe comes with a color coded ANSI mini connector: type J-black, type K-yellow, type T-blue, and type E-purple. • Custom designs or changes to this product... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -250 to 425
- Base, Noble and Refractory Metal Type: K
- Sensitive Length: 12
from Cole-Parmer
bull; Hollow Tube probes are designed to be more compactat and at a lower cost. • Response Time: 2-4 seconds or greater. • Each probe comes with a color coded ANSI mini connector: type J-black, type K-yellow, type T-blue, and type E-purple. • Custom designs or changes to this product... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -250 to 425
- Base, Noble and Refractory Metal Type: K
- Sensitive Length: 12
from Cole-Parmer
bull; PTFE-Insulated with Sealed Junction Used for Long-Term Immersion in Semi-Caustic Environments. • Each Probe is hermetically sealed and tested to 25psi. • Can be used for applications requiring an isolated junction. • Response Time: 0.75 seconds or greater. • All... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -250 to 400
- Base, Noble and Refractory Metal Type: K
from Cole-Parmer
bull; Each probe is 8 â € long and features a self-locking clip to ensure a sturdy hold onto the handle. • Ideal for switching out probes when working with multiple applications. • Response Time: 1.75-3 seconds or greater. • Each probe comes with a color coded ANSI mini... [See More]
- Configuration: Ungrounded Thermocouple
- Sensed Temperature: -250 to 1200
- Base, Noble and Refractory Metal Type: K
- Sensitive Length: 8