48 thermocouple and voltage channels. Very high-performance thermocouple measurements, <0.3 ° C accuracy. Supports all thermocouple types. 10-34 V DC powered with extended temperature range for harsh testing in harsh environments. Built-in cold junction compensation, open transducer... [See More]
- Inputs: Thermocouple Input; RTD Input; Bridge Input
- Analog Channels: 48
from AMETEK Programmable Power
24-bit, delta-sigma ADC, simultaneous sampling. Programmable Sample Rate up to 128kSPS. Full, Half & Quarter Bridge with 120 Ω, 350 Ω & 1k Ω bridge completion. Voltage Excitation: 0.5V to 10V. Current Excitation: 0.46mA. 2-Wire & 4-Wire Ohms/RTD. Bridge Zero Balancing. [See More]
- Inputs: RTD Input; Bridge Input
- Host Connection: Ethernet
- Analog Channels: 16
from Opto 22
The SNAP-AILC input module works with 2 mV/V and 3 mV/V load cells as a load cell front end. Using a separate 24 VDC power source (purchased separately), the module provides isolated 10 VDC bridge excitation for up to four 350 ohm or 415 ohm load cells. [See More]
- Inputs: Bridge Input
- Sampling Frequency: 0.1111
- Analog Channels: 2
- Resolution: 22
from ACCES I/O Products, Inc.
Remote Intelligent Data Acquisition and Control System. Distributed Input/Output is commonly used to reduce installation cost, " home-run" wiring, and potential noise interference. REMOTE ACCES pods installed in RIDACS systems let you install interfaces and control outputs close to the sensors and... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input
- Digital I/O Channels: 8
- Analog Channels: 32
- Resolution: 12
from Kistler Group
Measurement module (DAQ) for strain gauge bridges (full, half, quarter).* Suitable for KiDAQ Data Acquisition system types Portable, Rack and DIN Rail. 8 analog input channels. Galvanic isolation 500 VDC. A/D conversion: 20 kSps sampling rate per channel, 24 Bit resolution. DC bridge excitation... [See More]
- Inputs: Bridge Input
- Sampling Frequency: 20
- Analog Channels: 8
- Resolution: 24
from Encore Electronics, Inc.
The Model 220 provides a pure sinusoidal signal. of known strain to your strain gage measurement. system. This arrangement simulates actual vibration. signals and can be used with AC coupled amplifiers. [See More]
- Inputs: Bridge Input
- AC Voltage: .5V to 10V
- Form Factor: Stand-alone
- Excitation: Voltage
from CAS DataLoggers
The Environmental Data Logger. The dataTaker DT82E is an intelligent data logger that was designed with environmental applications in mind. The DT82E is a robust, stand alone, low power data logger featuring USB memory stick support, 18 bit resolution, extensive communications capabilities and... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
- Digital I/O Channels: 4
- Analog Channels: 6
- Sampling Frequency: 0.0250
from OMEGA Engineering, Inc.
The DP25B process meter accepts a wide variety of DC voltage and current inputs to cover any typical process application. Standard features include a full 4-digit three color (Red, Green, & Amber) programmable LED display, easy front panel scaling to virtually any engineering units, selectable... [See More]
- Inputs: Thermocouple Input; RTD Input; Bridge Input
- Sampling Frequency: 0.0030
- Analog Channels: 1
- Resolution: 15
from Opto 22
The SNAP-AILC-2 input module works with 3 mV/V and 4 mV/V load cells as a load cell front end. Using a separate 24 VDC power source (purchased separately), the module provides isolated 10 VDC bridge excitation for up to four 350 ohm or 415 ohm load cells. The SNAP-AILC-2 is primarily used with... [See More]
- Inputs: Bridge Input
- Sampling Frequency: 0.1111
- Analog Channels: 2
- Resolution: 22
from Kistler Group
Measurement module (DAQ) for strain gauges and inductive half and full bridges, LVDT, RVDT, quarter bridge with completion terminal.* Suitable for KiDAQ Data Acquisition system types Portable, Rack and DIN Rail. 2 analog and 4 digital input channels. Galvanic isolation 500 VDC. A/D conversion: 20... [See More]
- Inputs: Bridge Input
- Digital I/O Channels: 4
- Analog Channels: 2
- Sampling Frequency: 20
from Encore Electronics, Inc.
The Model 226-002 provides a calibrated sinusoidal signal to your strain gage measurement system. A precision cal-resistor. in series with a modulation signal is connected across the strain gage. The peak-to-peak value. of modulation signal is automatically set to. equal the bridge excitation mode. [See More]
- Inputs: Bridge Input
- AC Voltage: .25V to 15V
- Form Factor: Stand-alone
- Excitation: Voltage
from CAS DataLoggers
Internal GSM Modem. The dataTaker DT82EM is an intelligent data logger that incorporates a built-in GSM modem with email and SMS support for automated data and alarm transfer from remote sites. The DT82EM features USB memory stick support, 18 bit resolution, extensive communications capabilities and... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
- Digital I/O Channels: 4
- Analog Channels: 2
- Sampling Frequency: 0.0250
from OMEGA Engineering, Inc.
OMEGA ’s melt pressure indicators also function as transducer power supplies and signal conditioners. The DP434 Digital Model has a large 3 1 /2 digit LED display which is easy to read, even from a distance, while the DP409 Analog Model has a 6", 240 ° arc (international scale) for easy... [See More]
- Inputs: Bridge Input
- Form Factor: Panel / Chassis Mount
- Analog Channels: 1
- Excitation: Voltage
from Kistler Group
Universal measurement module (DAQ) for voltage, current, resistance, potentiometer, resistance thermometer (Pt100, Pt1000), thermocouples (Type B,E,J,K,L,N,R,S,T,U), strain gauges, IEPE sensors (Piezotron) and status.* Suitable for KiDAQ Data Acquisition system types Portable, Rack and DIN Rail. 2... [See More]
- Inputs: Thermocouple Input; Bridge Input; IEPE Sensors
- Digital I/O Channels: 2
- Analog Channels: 2
- Sampling Frequency: 100
from Encore Electronics, Inc.
The Model 176 is a computer-controlled charge amplifier module. It features variable gain and output scaling and will accept differential or single-ended inputs. The following parameters are displayed and adjustable: accelerometer sensitivity, differential or single-ended mode, scaling, filter... [See More]
- Inputs: Bridge Input
- Auxiliary Outputs: Analog Current Output
- Form Factor: PC Board
- User Interface: Computer Programmable
from CAS DataLoggers
The Industrial Data Logger. The dataTaker DT82I was designed for industrial applications that focus on flexible serial type communications such as RS232, RS422 and RS485. The DT82i is a robust, stand alone, low power data logger featuring USB memory stick support, 18 bit resolution, extensive... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
- Digital I/O Channels: 4
- Analog Channels: 6
- Sampling Frequency: 0.0250
from OMEGA Engineering, Inc.
bull;. High Accuracy Data Acquisition for Windows-Based Computers. •. 16 Single-Ended/8 Differential 14 Bit Analog Inputs, 8 Analog Outputs and 8 Digital I/O. •. Controller Card Includes 10 Counter/Timer Channels. •. Direct Connect to RTD, Thermocouple, Voltage, Thermistor, Bridge... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input
- Differential Channels: Yes
- Analog Channels: 16
- Digital I/O Channels: 8
from Kistler Group
Universal measurement module (DAQ) for voltage, current, resistance, potentiometer, resistance thermometer (Pt100, Pt1000), thermocouples (Type B,E,J,K,L,N,R,S,T,U) and strain gauges.* Suitable for KiDAQ Data Acquisition system types Portable, Rack and DIN Rail. 4 analog input channels. Galvanic... [See More]
- Inputs: Thermocouple Input; Bridge Input
- Sampling Frequency: 20
- Analog Channels: 4
- Resolution: 24
from Encore Electronics, Inc.
The Model 664 is a two-channel computer-controlled dynamic strain gage amplifier module. The following parameters are displayed and are adjustable: gain, zero, external cal, filter, excitation and excitation monitor. Each channel has its own isolated constant current excitation source. [See More]
- Inputs: Bridge Input
- Form Factor: PC Board
- Isolation: Isolated Excitation Source
- Excitation: Voltage; Current
from CAS DataLoggers
The Intelligent Logger. The dataTaker DT80 is an intelligent data logger with an extensive array of features that allow it to be used across a wide variety of applications. This robust, stand alone, low power data logger features USB memory stick support, 18 bit resolution, extensive communications... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Monolithic Temperature Sensors
- Digital I/O Channels: 12
- Analog Channels: 15
- Sampling Frequency: 0.0250
from OMEGA Engineering, Inc.
OMEGA introduces a new family of extremely accurate instruments for DIN rail mounting. The compact iDR Series signal conditioners and PID controllers are available with OMEGA's award-winning "embedded Internet" technology. With the Ethernet option, the instruments connect directly to a LAN and can... [See More]
- Inputs: Thermocouple Input; RTD Input; Bridge Input; Relay / Switch Input
- Isolation: Isolated Analog Voltage Output (optional feature); Isolated Digital Outputs (optional feature)
- Accuracy: 0.0300
- Form Factor: DIN Rail
from Encore Electronics, Inc.
The Model 665 is a combo computer-controlled static/dynamic strain gage amplifier module. The following parameters are displayed and are adjustable: gain, zero, external cal, filter, excitation and excitation monitor. Each channel has its own isolated constant current excitation source. [See More]
- Inputs: Bridge Input
- Form Factor: PC Board
- Isolation: Isolated Excitation Source
- Excitation: Voltage; Current
from CAS DataLoggers
Designed For Remote Applications. The dataTaker DT80M intelligent data logger is a fully featured low-powered logging platform with an integrated cellular modem, making it perfect for remote applications. The rugged design and wide operating temperature range of the DT80M provides reliable operation... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
- Digital I/O Channels: 12
- Analog Channels: 15
- Sampling Frequency: 0.0250
from OMEGA Engineering, Inc.
The OMEGA ® OM2 modular signal conditioning system provides a low cost, versatile method of interconnecting a variety of analog signals for measurement and control systems. The OM2 modules interface directly with sensors or analog signals such as strain gages, mV, thermocouples and RTD ’s. [See More]
- Inputs: Bridge Input
- Auxiliary Outputs: Analog Voltage Output
- Form Factor: DIN Rail
- User Interface: None
from Encore Electronics, Inc.
The Model FL639 strain gage amplifier is a low-priced, compact bridge amplifier, complete with voltage and current excitation, adjustable gain, zero, and bridge balance, lowpass filtering, and shunt calibration. The unit is mechanically and electrically compatible with Encore's other Flex-line... [See More]
- Inputs: Bridge Input
- Excitation: Voltage; Current
- Form Factor: DIN Rail
- Auxiliary Outputs: Analog Voltage Output; Analog Current Output
from CAS DataLoggers
The Smart Logger. The dataTaker DT85 data logger is an intelligent logger with an extensive array of features allowing it to be used across a wide variety of applications such as R &D, energy monitoring, environmental monitoring, temperature profiling and more. The DT85 is a robust, stand alone,... [See More]
- Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
- Digital I/O Channels: 8
- Analog Channels: 48
- Sampling Frequency: 0.0250
from OMEGA Engineering, Inc.
The easy-to-use DP3600 series meters can be user-programmed to work with a wide variety of pressure, flow and force transducers. Keys are appropriately labeled to eliminate any user guess work. All features such as limits, timers, display modes, setpoint, time-base etc. are totally programmable from... [See More]
- Inputs: Bridge Input
- Form Factor: Panel / Chassis Mount
- Analog Channels: 1
- DC Voltage: 0 to 10 V