RTD Data Acquisition Systems and Instruments

20 Results
Data Acquisition, Static Data Acquisition
from AMETEK Programmable Power

48 thermocouple and voltage channels. Very high-performance thermocouple measurements, <0.3 ° C accuracy. Supports all thermocouple types. 10-34 V DC powered with extended temperature range for harsh testing in harsh environments. Built-in cold junction compensation, open transducer... [See More]

  • Inputs: Thermocouple Input; RTD Input; Bridge Input
  • Analog Channels: 48
LXI Standard for Ethernet Testing Instruments & DAQ Systems, EX1400 Family
from AMETEK Programmable Power

24-bit, delta-sigma ADC, simultaneous sampling. Programmable Sample Rate up to 128kSPS. Full, Half & Quarter Bridge with 120 Ω, 350 Ω & 1k Ω bridge completion. Voltage Excitation: 0.5V to 10V. Current Excitation: 0.46mA. 2-Wire & 4-Wire Ohms/RTD. Bridge Zero Balancing. [See More]

  • Inputs: RTD Input; Bridge Input
  • Host Connection: Ethernet
  • Analog Channels: 16
Downhole Orientation Sensor and Data Logger -- 3DM-DH3™
from LORD MicroStrain Sensing Systems

Downhole Orientation Sensor and Data Logger. Overview. The 3DM-DH3 ™ is a downhole orientation sensor and datalogger. It incorporates acceleration sensors, magnetic field sensors, and temperature sensors, together with an on-board microprocessor, embedded software algorithm, non-volatile... [See More]

  • Inputs: Accelerometer Input; RTD Input
  • Data Logger: Datalogger
  • Resolution: 24
  • Form Factor: PC Board
Signal Acquisition Module for Motorsports -- CAN8 Series
from PMC Engineering LLC

This CAN Signal Acquisition Module integrates a high quality multi-channel data acquisition system, high performance Micro-controller (MCU) and CAN interface to provide access to external analog sensors via a Controller Area Network (CAN). The Module offers an array of configuration options in terms... [See More]

  • Inputs: RTD Input; Speed
  • Sampling Frequency: 1
  • Analog Channels: 8
  • Resolution: 16
Analog Input Isolated -- AD10T2
from Opto 22

G1 100 Ohm RTD Analog Input Isolated [See More]

  • Inputs: RTD Input
  • Resolution: 12
  • Analog Channels: 1
  • Isolation: Isolated
Remote Intelligent Data Acquisition and Control System -- RIDACS
from ACCES I/O Products, Inc.

Remote Intelligent Data Acquisition and Control System. Distributed Input/Output is commonly used to reduce installation cost, " home-run" wiring, and potential noise interference. REMOTE ACCES pods installed in RIDACS systems let you install interfaces and control outputs close to the sensors and... [See More]

  • Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input
  • Digital I/O Channels: 8
  • Analog Channels: 32
  • Resolution: 12
Data Acquisition System -- Q.monixx A117
from Gantner Instruments, Inc.

Q.monixx is a new addition to the Q.series product family – the ideal edge computing and data logging solution for reliable process control and asset monitoring. The standard I/O configuration for the Q.monixx includes up to 8 universal analog inputs, 8 digital inputs, 4 digital outputs, 2... [See More]

  • Inputs: RTD Input; Tach; Relay / Switch Input; Status, Resistance
  • Digital I/O Channels: 14
  • Analog Channels: 8
  • Resolution: 24
Measurement Module for RTD (Pt100, Pt1000) and Resistance -- 5522A
from Kistler Group

Measurement module (DAQ) for RTD (Pt100, Pt1000) or resistance in 3or 4wire technique.* Suitable for KiDAQ Data Acquisition system types Portable, Rack and DIN Rail. 4 analog input channels. Galvanic isolation 500 VDC. A/D conversion: 10 Sps sampling rate per channel, 24 Bit resolution [See More]

  • Inputs: RTD Input
  • Sampling Frequency: 0.0100
  • Analog Channels: 4
  • Resolution: 24
Cellular 2 Channel Data Logger -- LogBox 3G
from CAS DataLoggers

Description. The Novus LogBox 3G Cellular 2 Channel Data Logger. The LogBox 3G provides 2 universal analog inputs, 1 digital input and 1 digital output with an internal 3G wireless cellular modem and compatibility with the NOVUS Cloud web portal. The universal inputs accept thermocouples and RTD... [See More]

  • Inputs: Thermocouple Input; RTD Input
  • Digital I/O Channels: 1
  • Analog Channels: 2
  • Resolution: 15
1/8 DIN Process Meter & Controller -- DP25B
from OMEGA Engineering, Inc.

The DP25B process meter accepts a wide variety of DC voltage and current inputs to cover any typical process application. Standard features include a full 4-digit three color (Red, Green, & Amber) programmable LED display, easy front panel scaling to virtually any engineering units, selectable... [See More]

  • Inputs: Thermocouple Input; RTD Input; Bridge Input
  • Sampling Frequency: 0.0030
  • Analog Channels: 1
  • Resolution: 15
Analog Temperature Input Module -- SNAP-AIRTD
from Opto 22

The SNAP-AIRTD provides two channels of analog temperature input. Nominal input range is -200 to +850 degrees C. Although the two channels are not isolated from each other, the module is transformer isolated and optically isolated from other modules and devices. Modules are factory calibrated. [See More]

  • Inputs: RTD Input
  • Sampling Frequency: 0.0100
  • Analog Channels: 2
  • Isolation: Isolated
Compact, Universal Data Logger -- Delphin Loggito LAN Logger
from CAS DataLoggers

The Loggito LAN Data Logger by Delphin proves that good things do indeed come in small packages! The Loggito is excellent for distributed monitoring systems, data acquisition with a low number of channels and other low power applications in a wide variety of industries. The Loggito can be used as a... [See More]

  • Inputs: Thermocouple Input; RTD Input
  • Digital I/O Channels: 8
  • Analog Channels: 8
  • Sampling Frequency: 1
4-Channel RTD Input Data Acquisition Module -- PT-104A
from OMEGA Engineering, Inc.

The PT-104A is a four-channel, high-resolution temperature data acquisition module for use with PT100 and PT1000 RTD sensors. It can also be used to measure resistance (375 Ω and 10,000 Ω ranges) and voltage (115 mV or 2.5 V ranges). In PT100/PT1000/ resistance mode, the unit uses a four... [See More]

  • Inputs: RTD Input
  • Differential Channels: Yes (optional feature)
  • Analog Channels: 4
  • Form Factor: DIN Rail
RTD Input Isolated -- AD14T
from Opto 22

10 Ohm Rtd Input Isolated [See More]

  • Inputs: RTD Input
  • Resolution: 12
  • Analog Channels: 1
  • Isolation: Isolated
Environmental Data Logger -- dataTaker® DT82E
from CAS DataLoggers

The Environmental Data Logger. The dataTaker DT82E is an intelligent data logger that was designed with environmental applications in mind. The DT82E is a robust, stand alone, low power data logger featuring USB memory stick support, 18 bit resolution, extensive communications capabilities and... [See More]

  • Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
  • Digital I/O Channels: 4
  • Analog Channels: 6
  • Sampling Frequency: 0.0250
Dual-Channel Process Monitor -- DP3300
from OMEGA Engineering, Inc.

Highly versatile, the DP3300 series is a dual input meter. The meter can either monitor two analog inputs or an analog input and a pulse input. On the analog channel, signals from thermocouples, RTD's, or thermistors are linearized and displayed in degrees Centigrade or Fahrenheit. Voltage and... [See More]

  • Inputs: Thermocouple Input; Thermistor Input; RTD Input; Tach
  • Form Factor: Panel / Chassis Mount
  • Analog Channels: 2
  • DC Voltage: 0 to 10 V
Environmental Data Logger with Modem -- dataTaker® DT82EM
from CAS DataLoggers

Internal GSM Modem. The dataTaker DT82EM is an intelligent data logger that incorporates a built-in GSM modem with email and SMS support for automated data and alarm transfer from remote sites. The DT82EM features USB memory stick support, 18 bit resolution, extensive communications capabilities and... [See More]

  • Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
  • Digital I/O Channels: 4
  • Analog Channels: 2
  • Sampling Frequency: 0.0250
Ethernet-Based Data Acquisition System -- OMB-DAQSCAN-2001
from OMEGA Engineering, Inc.

The OMB-DAQSCAN-2000 Series of Ethernet-based data acquisition system components provides analog, digital and frequency I/O capability for Ethernet-based test systems. All OMB-DAQSCAN-2000 models are packaged in a 1U high-full rack package and include a rack-mount kit that can attach to either the... [See More]

  • Inputs: Thermocouple Input; Thermistor Input; RTD Input; Tach; Timer / Clock Input
  • Differential Channels: Yes
  • Analog Channels: 16
  • Digital I/O Channels: 40
Industrial Data Logger -- dataTaker® DT82i
from CAS DataLoggers

The Industrial Data Logger. The dataTaker DT82I was designed for industrial applications that focus on flexible serial type communications such as RS232, RS422 and RS485. The DT82i is a robust, stand alone, low power data logger featuring USB memory stick support, 18 bit resolution, extensive... [See More]

  • Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input; Tach; Monolithic Temperature Sensors
  • Digital I/O Channels: 4
  • Analog Channels: 6
  • Sampling Frequency: 0.0250
instruNet Data Acquisition Card -- INET
from OMEGA Engineering, Inc.

bull;. High Accuracy Data Acquisition for Windows-Based Computers. •. 16 Single-Ended/8 Differential 14 Bit Analog Inputs, 8 Analog Outputs and 8 Digital I/O. •. Controller Card Includes 10 Counter/Timer Channels. •. Direct Connect to RTD, Thermocouple, Voltage, Thermistor, Bridge... [See More]

  • Inputs: Thermocouple Input; Thermistor Input; RTD Input; Bridge Input
  • Differential Channels: Yes
  • Analog Channels: 16
  • Digital I/O Channels: 8